Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.3 |
148 |
LiYY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.7 |
148 |
LiYY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.4 |
148 |
LiYY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.7 |
7.5 |
148 |
LiYY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.6 |
148 |
LiYY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10 |
148 |
LiYY TP 12x2x0.14 |
12/0.12 |
0.35 |
1 |
10.4 |
148 |
LiYY TP 15x2x0.14 |
12/0.12 |
0.35 |
1.1 |
11.6 |
148 |
0.25mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6 |
79.9 |
LiYY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6.4 |
79.9 |
LiYY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.7 |
7.2 |
79.9 |
LiYY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8.8 |
79.9 |
LiYY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.8 |
79.9 |
LiYY TP 10x2x0.25 |
14/0.15 |
0.4 |
1 |
11.5 |
79.9 |
LiYY TP 12x2x0.25 |
14/0.15 |
0.4 |
1 |
12.1 |
79.9 |
LiYY TP 15x2x0.25 |
14/0.15 |
0.4 |
1.1 |
13.5 |
79.9 |
0.34mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.6 |
6.7 |
57 |
LiYY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.6 |
7.2 |
57 |
LiYY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.7 |
8 |
57 |
LiYY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10 |
57 |
LiYY TP 8x2x0.34 |
20/0.15 |
0.4 |
1 |
11.4 |
57 |
LiYY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
LiYY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.4 |
57 |
LiYY TP 15x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.9 |
57 |
0.50mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.7 |
7.5 |
39 |
LiYY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.7 |
8.1 |
39 |
LiYY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9 |
39 |
LiYY TP 6x2x0.5 |
16/0.20 |
0.45 |
1 |
11.2 |
39 |
LiYY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
12.8 |
39 |
LiYY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
14.7 |
39 |
LiYY TP 12x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15 |
39 |
LiYY TP 15x2x0.5 |
16/0.20 |
0.45 |
1.3 |
16.7 |
39 |
0.75mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.7 |
8.6 |
26 |
LiYY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.5 |
26 |
LiYY TP 4x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.4 |
26 |
LiYY TP 6x2x0.75 |
24/0.20 |
0.5 |
1 |
12.7 |
26 |
LiYY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.1 |
14.5 |
26 |
LiYY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.2 |
16.7 |
26 |
LiYY TP 12x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.6 |
26 |
LiYY TP 15x2x0.75 |
24/0.20 |
0.5 |
1.4 |
19.6 |
26 |
1.0mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
LiYY TP 3x2x1.0 |
32/0.20 |
0.6 |
1 |
11.4 |
19.5 |
LiYY TP 4x2x1.0 |
32/0.20 |
0.6 |
1 |
12.3 |
19.5 |
LiYY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15.2 |
19.5 |
LiYY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
16.6 |
19.5 |
LiYY TP 10x2x1.0 |
32/0.20 |
0.6 |
1.4 |
19.8 |
19.5 |
1.5mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY TP 2x2x1.5 |
30/0.25 |
0.6 |
1 |
11.5 |
13.3 |
LiYY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
12.7 |
13.3 |
LiYY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
13.9 |
13.3 |
LiYY TP 6x2x1.5 |
30/0.25 |
0.6 |
1.3 |
16.9 |
13.3 |
LiYY TP 8x2x1.5 |
30/0.25 |
0.6 |
1.3 |
18.3 |
13.3 |
Product detail pictures:
Related Product Guide:
Each individual member from our large performance revenue crew values customers' needs and company communication for 18 Years Factory File Transfer Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Sri Lanka, Spain, Japan, Our items are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
By Octavia from Sweden - 2018.05.22 12:13
Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
By Lisa from Atlanta - 2017.09.28 18:29