2021 High Quality Outdoor Data Cable - LiYcY TP Multipair Screened Control Cable – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

It adheres on the tenet "Honest, industrious, enterprising, innovative" to acquire new solutions regularly. It regards shoppers, success as its very own success. Let us establish prosperous future hand in hand for Data Center Rack Cabinet, Rack Mount Enclosure, Bs5308 Cable, If possible, be sure to send your needs with a detailed list including the style/item and quantity you require. We will then deliver our greatest price ranges to you.
2021 High Quality Outdoor Data Cable - LiYcY TP Multipair Screened Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR at
20℃ (Ω/km)

LiYcY TP 1x2x0.14

12/0.12

0.35

0.7

4.4

148

LiYcY TP 2x2x0.14

12/0.12

0.35

0.7

6.1

148

LiYcY TP 3x2x0.14

12/0.12

0.35

0.8

6.7

148

LiYcY TP 4x2x0.14

12/0.12

0.35

0.8

7.2

148

LiYcY TP 6x2x0.14

12/0.12

0.35

0.8

8.3

148

LiYcY TP 8x2x0.14

12/0.12

0.35

0.8

9.4

148

LiYcY TP 10x2x0.14

12/0.12

0.35

0.9

10.8

148

LiYcY TP 12x2x0.14

12/0.12

0.35

1.0

11.4

148

0.25mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.25

14/0.15

0.4

0.7

4.8

79.9

LiYcY TP 2x2x0.25

14/0.15

0.4

0.8

7

79.9

LiYcY TP 3x2x0.25

14/0.15

0.4

0.8

7.4

79.9

LiYcY TP 4x2x0.25

14/0.15

0.4

0.8

8

79.9

LiYcY TP 6x2x0.25

14/0.15

0.4

0.8

9.6

79.9

LiYcY TP 8x2x0.25

14/0.15

0.4

0.9

10.8

79.9

LiYcY TP 10x2x0.25

14/0.15

0.4

1.0

12.3

79.9

LiYcY TP 12x2x0.25

14/0.15

0.4

1.1

12.6

79.9

0.34mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.34

20/0.15

0.4

0.7

5.2

57

LiYcY TP 2x2x0.34

20/0.15

0.4

0.8

7.7

57

LiYcY TP 3x2x0.34

20/0.15

0.4

0.8

8.2

57

LiYcY TP 4x2x0.34

20/0.15

0.4

0.8

9

57

LiYcY TP 6x2x0.34

20/0.15

0.4

0.9

10.8

57

LiYcY TP 8x2x0.34

20/0.15

0.4

1.0

12.2

57

LiYcY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYcY TP 12x2x0.34

20/0.15

0.4

1.2

14.7

57

0.50mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.5

16/0.20

0.45

0.7

5.6

39

LiYcY TP 2x2x0.5

16/0.20

0.45

0.8

8.3

39

LiYcY TP 3x2x0.5

16/0.20

0.45

0.8

9.1

39

LiYcY TP 4x2x0.5

16/0.20

0.45

0.9

10

39

LiYcY TP 6x2x0.5

16/0.20

0.45

1.0

12

39

LiYcY TP 8x2x0.5

16/0.20

0.45

1.1

13.1

39

LiYcY TP 10x2x0.5

16/0.20

0.45

1.2

15.5

39

0.75mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.75

24/0.20

0.5

0.8

6.4

26

LiYcY TP 2x2x0.75

24/0.20

0.5

0.8

9.6

26

LiYcY TP 3x2x0.75

24/0.20

0.5

0.9

10.5

26

LiYcY TP 4x2x0.75

24/0.20

0.5

1.0

11.4

26

LiYcY TP 6x2x0.75

24/0.20

0.5

1.1

13.7

26

LiYcY TP 8x2x0.75

24/0.20

0.5

1.2

15

26

LiYcY TP 10x2x0.75

24/0.20

0.5

1.3

17.7

26

1.0mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.0

32/0.20

0.6

0.8

7.2

19.5

LiYcY TP 2x2x1.0

32/0.20

0.6

0.9

11.1

19.5

LiYcY TP 3x2x1.0

32/0.20

0.6

1.0

12.2

19.5

LiYcY TP 4x2x1.0

32/0.20

0.6

1.0

13.1

19.5

LiYcY TP 6x2x1.0

32/0.20

0.6

1.2

15

19.5

LiYcY TP 8x2x1.0

32/0.20

0.6

1.3

17.4

19.5

1.5mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.5

30/0.25

0.6

0.8

7.8

13.3

LiYcY TP 2x2x1.5

30/0.25

0.6

1.0

12.3

13.3

LiYcY TP 3x2x1.5

30/0.25

0.6

1.1

13.5

13.3

LiYcY TP 4x2x1.5

30/0.25

0.6

1.2

14.7

13.3


Product detail pictures:

2021 High Quality Outdoor Data Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures

2021 High Quality Outdoor Data Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures


Related Product Guide:

Now we have highly developed devices. Our items are exported towards the USA, the UK and so on, enjoying a great popularity among the customers for 2021 High Quality Outdoor Data Cable - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: Naples, Mozambique, Mozambique, We take measure at any price to attain essentially the most up-to-date gear and procedures. The packing of nominated brand is our a further distinguishing feature. The solutions to assure years of trouble-free service has attracted a great deal customers. The goods are obtainable in improved designs and richer variety, they're produced scientifically of purely raw supplies. It accessible in a variety of designs and specifications for the selection. The newest forms are much far better than the previous one and they're extremely popular with several clients.
  • Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Tony from Venezuela - 2018.09.23 18:44
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Karen from Palestine - 2017.04.08 14:55
    Write your message here and send it to us