2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for 2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Amsterdam, USA, Comoros, We have a good reputation for stable quality products, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with customers both at home and abroad. We expect sincere cooperation and common development!
By Prudence from Kenya - 2018.06.09 12:42
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
By Renee from Toronto - 2018.04.25 16:46