2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

We now have many fantastic staff members customers superior at advertising, QC, and working with varieties of troublesome problem within the generation system for Network Switch Rack, Computer Racks And Cabinets, Keystone Wall Jack, By more than 8 years of company, now we have accumulated rich experience and advanced technologies from the generation of our merchandise.
2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.14

12/0.12

0.35

0.4

3.2

148

LiYY 3×0.14

12/0.12

0.35

0.4

3.5

148

LiYY 4×0.14

12/0.12

0.35

0.5

3.9

148

LiYY 5×0.14

12/0.12

0.35

0.5

4.3

148

LiYY 7×0.14

12/0.12

0.35

0.6

4.8

148

LiYY 8×0.14

12/0.12

0.35

0.6

5.2

148

LiYY 10×0.14

12/0.12

0.35

0.7

6.2

148

LiYY 12×0.14

12/0.12

0.35

0.7

6.5

148

LiYY 14×0.14

12/0.12

0.35

0.7

6.7

148

0.25mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY 3×0.25

14/0.15

0.4

0.4

3.9

79.9

LiYY 4×0.25

14/0.15

0.4

0.5

4.4

79.9

LiYY 5×0.25

14/0.15

0.4

0.5

4.8

79.9

LiYY 7×0.25

14/0.15

0.4

0.6

5.4

79.9

LiYY 8×0.25

14/0.15

0.4

0.6

5.8

79.9

LiYY 10×0.25

14/0.15

0.4

0.7

7

79.9

LiYY 12×0.25

14/0.15

0.4

0.7

7.3

79.9

LiYY 14×0.25

14/0.15

0.4

0.7

7.6

79.9

0.34mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.34

20/0.15

0.4

0.5

4.2

57

LiYY 3×0.34

20/0.15

0.4

0.5

4.5

57

LiYY 4×0.34

20/0.15

0.4

0.6

5.1

57

LiYY 5×0.34

20/0.15

0.4

0.6

5.5

57

LiYY 7×0.34

20/0.15

0.4

0.7

6.2

57

LiYY 8×0.34

20/0.15

0.4

0.7

6.7

57

LiYY 10×0.34

20/0.15

0.4

0.8

8

57

LiYY 12×0.34

20/0.15

0.4

0.8

8.3

57

LiYY 14×0.34

20/0.15

0.4

0.8

8.7

57

0.50mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.5

16/0.20

0.45

0.6

4.8

39

LiYY 3×0.5

16/0.20

0.45

0.6

5.2

39

LiYY 4×0.5

16/0.20

0.45

0.6

5.6

39

LiYY 5×0.5

16/0.20

0.45

0.6

6.1

39

LiYY 7×0.5

16/0.20

0.45

0.6

6.6

39

LiYY 8×0.5

16/0.20

0.45

0.7

7.4

39

LiYY 10×0.5

16/0.20

0.45

0.7

8.6

39

LiYY 12×0.5

16/0.20

0.45

0.8

9.2

39

LiYY 14×0.5

16/0.20

0.45

0.9

9.8

39

0.75mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.75

24/0.20

0.5

0.6

5.4

26

LiYY 3×0.75

24/0.20

0.5

0.6

5.8

26

LiYY 4×0.75

24/0.20

0.5

0.6

6.3

26

LiYY 5×0.75

24/0.20

0.5

0.7

7.1

26

LiYY 7×0.75

24/0.20

0.5

0.7

7.7

26

LiYY 8×0.75

24/0.20

0.5

0.8

8.6

26

LiYY 10×0.75

24/0.20

0.5

0.8

10

26

LiYY 12×0.75

24/0.20

0.5

0.9

10.6

26

LiYY 14×0.75

24/0.20

0.5

1

11.3

26

1.0mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY 3×1.0

32/0.20

0.6

0.6

6.7

19.5

LiYY 4×1.0

32/0.20

0.6

0.7

7.5

19.5

LiYY 5×1.0

32/0.20

0.6

0.7

8.2

19.5

LiYY 7×1.0

32/0.20

0.6

0.8

9.1

19.5

1.5mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY 3×1.5

30/0.25

0.6

0.7

7.6

13.3

LiYY 4×1.5

30/0.25

0.6

0.7

8.2

13.3

LiYY 5×1.5

30/0.25

0.6

0.8

9.2

13.3

LiYY 7×1.5

30/0.25

0.6

0.9

10.5

13.3


Product detail pictures:

2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures

2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures


Related Product Guide:

To be able to ideal satisfy client's requirements, all of our operations are strictly performed in line with our motto "High High-quality, Competitive Price tag, Fast Service" for 2021 Latest Design Orange Instrument Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Croatia, Wellington, St. Petersburg, Our company upholds the spirit of "innovation, harmony, team work and sharing, trails, pragmatic progress". Give us a chance and we will prove our capability. With your kind help, we believe that we can create a bright future with you together.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Austin Helman from Cancun - 2017.12.19 11:10
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Betsy from Ottawa - 2018.09.23 18:44
    Write your message here and send it to us