2021 New Style Data Cable Wire - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU
2021 New Style Data Cable Wire - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU Detail:
Application
1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-pair cables are available. It could be widely used for production process control and Device Converter audio instrument.
2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire shielded are optional.
3. PVC or LSZH sheath are both available.
4. Instrumentation cable is a multi-conductor cable, generally single or multiple pairs, used for monitoring or controlling the transmission of power and electrical signals related to the process.
5. Instrumentation cables connect instrumentation to electrical equipment, and in industrial equipment, control processes are signals generated by sensors that are transmitted through panels, controllers, and other equipment.
6. The twist pair cables can reduce external interference or internal crosstalk. Single pair shielding is usually the transmission of analog signals. Overall shielding is generally the transmission of digital signals. Meter cable is mainly used in industrial petroleum, mining, chemical and other need process control or measurement automation plants.
Constructions
1. Conductor: Stranded Tinned Copper Wire
2. Insulation: Polyolefin, PVC
3. Cabling: Twist Pairs laying-up
4. Screened: Individually Screened (Optional)
Al-PET tape with Tinned Copper Drain Wire
5. Sheath: PVC/LSZH
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
BS EN 60228
BS EN 50290
RoHS Directives
IEC60332-1
Identification of Insulation
Operating Voltage |
300V, 600V |
Test Voltage |
1.0 KVdc |
Conductor DCR |
91.80 Ω/km (Max. @ 20°C) for 24AWG |
57.0 Ω/km (Max. @ 20°C) for 22AWG |
|
39.50 Ω/km (Max. @ 20°C) for 20AWG |
|
25.0 Ω/km (Max. @ 20°C) for 18AWG |
|
14.0 Ω/km (Max. @ 20°C) for 16AWG |
|
9.3 Ω/km (Max. @ 20°C) for 14AWG |
|
Insulation Resistance |
100 MΩhms/km (Min.) |
Part No. |
Conductor Construction |
Insulation |
Screen |
Sheath |
|
Material |
Size |
||||
AP9414 |
TC |
1x2x22AWG |
PVC |
Al-foil |
PVC |
AP8761 |
TC |
1x2x22AWG |
S-PE |
Al-foil |
PVC |
AP8761NH |
TC |
1x2x22AWG |
S-PP |
Al-foil |
LSZH |
AP9451 |
TC |
1x2x22AWG |
S-PP |
Al-foil |
PVC |
AP8451 |
|||||
AP1266A |
|||||
AP1503A |
TC |
1x2x22AWG |
PVC |
Al-foil |
PVC |
AP9154 |
TC |
1x2x20AWG |
PVC |
Al-foil |
PVC |
AP8762 |
TC |
1x2x20AWG |
S-PE |
Al-foil |
PVC |
AP8762NH |
TC |
1x2x20AWG |
S-PE |
Al-foil |
LSZH |
AP8760 |
TC |
1x2x18AWG |
S-PE |
Al-foil |
PVC |
AP9460 |
|||||
AP8760NH |
TC |
1x2x18AWG |
S-PE |
Al-foil |
LSZH |
AP8719 |
TC |
1x2x16AWG |
S-PE |
Al-foil |
PVC |
AP8719NH |
TC |
1x2x16AWG |
S-PE |
Al-foil |
LSZH |
AP8720 |
TC |
1x2x14AWG |
S-PE |
Al-foil |
PVC |
AP8718 |
TC |
1x2x12AWG |
S-PE |
Al-foil |
PVC |
AP9302 |
TC |
2x2x22AWG |
PVC |
Al-foil |
PVC |
AP9305 |
TC |
4x2x22AWG |
PVC |
Al-foil |
PVC |
AP9306 |
TC |
6x2x22AWG |
PVC |
Al-foil |
PVC |
AP9309 |
TC |
9x2x22AWG |
PVC |
Al-foil |
PVC |
AP1508A |
TC |
1x2x24AWG |
S-PE |
Al-foil |
PVC |
AP8641 |
TC |
1x2x24AWG |
S-PE |
Al-foil |
PVC |
AP1883A |
TC |
1x2x24AWG |
S-PP |
Al-foil |
PVC |
AP9990 |
TC |
3x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9991 |
TC |
6x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9992 |
TC |
9x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9993 |
TC |
12x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP8767 |
TC |
3x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8768 |
TC |
6x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8764 |
TC |
9x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8723 |
TC |
2x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8723NH |
TC |
2x2x22AWG |
S-PP |
IS Al-foil |
LSZH |
AP8778 |
TC |
6x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8774 |
TC |
9x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8775 |
TC |
11x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP9402 |
TC |
2x2x20AWG |
PVC |
IS Al-foil |
PVC |
AP9883 |
TC |
3x2x20AWG |
S-PP |
IS Al-foil |
PE |
AP9886 |
TC |
6x2x20AWG |
S-PP |
IS Al-foil |
PE |
AP9873 |
TC |
3x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9874 |
TC |
6x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9875 |
TC |
9x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9773 |
TC |
3x2x18AWG |
S-PP |
IS Al-foil |
PVC |
AP9774 |
TC |
6x2x18AWG |
S-PP |
IS Al-foil |
PVC |
AP9775 |
TC |
9x2x18AWG |
S-PP |
IS Al-foil |
PVC |
(Notes: Other cores are available upon request.)
Product detail pictures:
Related Product Guide:
Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for 2021 New Style Data Cable Wire - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU , The product will supply to all over the world, such as: Costa Rica, Detroit, Madras, We adhere to the honest, efficient, practical win-win running mission and people-oriented business philosophy. Excellent quality, reasonable price and customer satisfaction are always pursued! If you are interested in our items, just try to contact us for more details!
By Agatha from Slovenia - 2017.09.30 16:36
As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!