We are also focusing on enhancing the things administration and QC program in order that we could keep fantastic advantage within the fiercely-competitive enterprise for Fiber Optic Patching, Free Server Rack, Network Rack, We welcome clients, enterprise associations and friends from all components from the earth to make contact with us and find cooperation for mutual positive aspects.
2021 New Style Data Cable Wire - LiHH Multicore Control Cable (Halogen Free) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
5. Sheath: LSZH

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.14

12/0.12

0.3

0.6

3.4

148

LiHH 3×0.14

12/0.12

0.3

0.6

3.6

148

LiHH 4×0.14

12/0.12

0.3

0.6

3.9

148

LiHH 5×0.14

12/0.12

0.3

0.6

4.2

148

LiHH 7×0.14

12/0.12

0.3

0.6

4.5

148

LiHH 8×0.14

12/0.12

0.3

0.6

4.8

148

LiHH 10×0.14

12/0.12

0.3

0.6

5.6

148

LiHH 12×0.14

12/0.12

0.3

0.7

6

148

LiHH 14×0.14

12/0.12

0.3

0.7

6.3

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.25

14/0.15

0.3

0.6

3.8

79.9

LiHH 3×0.25

14/0.15

0.3

0.6

4.1

79.9

LiHH 4×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHH 5×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHH 7×0.25

14/0.15

0.3

0.6

5.1

79.9

LiHH 8×0.25

14/0.15

0.3

0.6

5.5

79.9

LiHH 10×0.25

14/0.15

0.3

0.7

6.6

79.9

LiHH 12×0.25

14/0.15

0.3

0.7

6.9

79.9

LiHH 14×0.25

14/0.15

0.3

0.7

7.2

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.34

20/0.15

0.3

0.6

4

57

LiHH 3×0.34

20/0.15

0.3

0.6

4.3

57

LiHH 4×0.34

20/0.15

0.3

0.6

4.6

57

LiHH 5×0.34

20/0.15

0.3

0.6

5

57

LiHH 7×0.34

20/0.15

0.3

0.6

5.4

57

LiHH 8×0.34

20/0.15

0.3

0.6

5.8

57

LiHH 10×0.34

20/0.15

0.3

0.7

7

57

LiHH 12×0.34

20/0.15

0.3

0.7

7.3

57

LiHH 14×0.34

20/0.15

0.3

0.7

7.6

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.5

16/0.20

0.3

0.6

4.3

39

LiHH 3×0.5

16/0.20

0.3

0.6

4.6

39

LiHH 4×0.5

16/0.20

0.3

0.6

5

39

LiHH 5×0.5

16/0.20

0.3

0.6

5.4

39

LiHH 7×0.5

16/0.20

0.3

0.6

5.9

39

LiHH 8×0.5

16/0.20

0.3

0.7

6.5

39

LiHH 10×0.5

16/0.20

0.3

0.7

7.6

39

LiHH 12×0.5

16/0.20

0.3

0.7

7.9

39

LiHH 14×0.5

16/0.20

0.3

0.7

8.3

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.75

24/0.20

0.4

0.6

5.2

26

LiHH 3×0.75

24/0.20

0.4

0.6

5.6

26

LiHH 4×0.75

24/0.20

0.4

0.6

6.1

26

LiHH 5×0.75

24/0.20

0.4

0.7

6.6

26

LiHH 7×0.75

24/0.20

0.4

0.7

7.2

26

LiHH 8×0.75

24/0.20

0.4

0.7

8

26

LiHH 10×0.75

24/0.20

0.4

0.8

9.6

26

LiHH 12×0.75

24/0.20

0.4

0.8

10

26

LiHH 14×0.75

24/0.20

0.4

0.9

10.7

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.0

32/0.20

0.5

0.6

5.8

19.5

LiHH 3×1.0

32/0.20

0.5

0.6

6.3

19.5

LiHH 4×1.0

32/0.20

0.5

0.7

7

19.5

LiHH 5×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHH 7×1.0

32/0.20

0.5

0.9

8.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.5

30/0.25

0.5

0.6

6.4

13.3

LiHH 3×1.5

30/0.25

0.5

0.7

7.1

13.3

LiHH 4×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHH 5×1.5

30/0.25

0.5

0.8

8.6

13.3

LiHH 7×1.5

30/0.25

0.5

1.0

9.6

13.3


Product detail pictures:

2021 New Style Data Cable Wire - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures

2021 New Style Data Cable Wire - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures


Related Product Guide:

Adhering to the principle of "quality, service, efficiency and growth", we have gained trusts and praises from domestic and international client for 2021 New Style Data Cable Wire - LiHH Multicore Control Cable (Halogen Free) – AIPU , The product will supply to all over the world, such as: Sri Lanka, Belize, Maldives, Our company has built stable business relationships with many well-known domestic companies as well as oversea customers. With the goal of providing high quality products to customers at low cots, we've been committed to improving its capacities in research, development, manufacturing and management. We have honored to receive recognition from our customers. Till now we have now passed ISO9001 in 2005 and ISO/TS16949 in 2008. Enterprises of "quality of survival, the credibility of development" for the purpose, sincerely welcome domestic and foreign businessmen to visit to discuss cooperation.
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Tony from Haiti - 2018.06.28 19:27
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Rae from Sudan - 2018.07.27 12:26
    Write your message here and send it to us