Best Price On Irrigation Control Cable - LiYY TP Multipair Control Cable – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

Our goal is to provide high quality products at competitive prices, and top-notch service to customers around the world. We are ISO9001, CE, and GS certified and strictly adhere to their quality specifications for Broadband Data Cable, Building Cable, Cat5e Cable, We believe that in good quality more than quantity. Before export of the hair there is strict top quality control check during treatment as per international good quality standards.
Best Price On Irrigation Control Cable - LiYY TP Multipair Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.14

12/0.12

0.35

0.4

3.2

148

LiYY TP 2x2x0.14

12/0.12

0.35

0.6

5.3

148

LiYY TP 3x2x0.14

12/0.12

0.35

0.6

5.7

148

LiYY TP 4x2x0.14

12/0.12

0.35

0.7

6.4

148

LiYY TP 6x2x0.14

12/0.12

0.35

0.7

7.5

148

LiYY TP 8x2x0.14

12/0.12

0.35

0.8

8.6

148

LiYY TP 10x2x0.14

12/0.12

0.35

0.9

10

148

LiYY TP 12x2x0.14

12/0.12

0.35

1

10.4

148

LiYY TP 15x2x0.14

12/0.12

0.35

1.1

11.6

148

0.25mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY TP 2x2x0.25

14/0.15

0.4

0.6

6

79.9

LiYY TP 3x2x0.25

14/0.15

0.4

0.6

6.4

79.9

LiYY TP 4x2x0.25

14/0.15

0.4

0.7

7.2

79.9

LiYY TP 6x2x0.25

14/0.15

0.4

0.8

8.8

79.9

LiYY TP 8x2x0.25

14/0.15

0.4

0.8

9.8

79.9

LiYY TP 10x2x0.25

14/0.15

0.4

1

11.5

79.9

LiYY TP 12x2x0.25

14/0.15

0.4

1

12.1

79.9

LiYY TP 15x2x0.25

14/0.15

0.4

1.1

13.5

79.9

0.34mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.34

20/0.15

0.4

0.5

4.2

57

LiYY TP 2x2x0.34

20/0.15

0.4

0.6

6.7

57

LiYY TP 3x2x0.34

20/0.15

0.4

0.6

7.2

57

LiYY TP 4x2x0.34

20/0.15

0.4

0.7

8

57

LiYY TP 6x2x0.34

20/0.15

0.4

0.9

10

57

LiYY TP 8x2x0.34

20/0.15

0.4

1

11.4

57

LiYY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYY TP 12x2x0.34

20/0.15

0.4

1.1

13.4

57

LiYY TP 15x2x0.34

20/0.15

0.4

1.2

14.9

57

0.50mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.5

16/0.20

0.45

0.6

4.8

39

LiYY TP 2x2x0.5

16/0.20

0.45

0.7

7.5

39

LiYY TP 3x2x0.5

16/0.20

0.45

0.7

8.1

39

LiYY TP 4x2x0.5

16/0.20

0.45

0.8

9

39

LiYY TP 6x2x0.5

16/0.20

0.45

1

11.2

39

LiYY TP 8x2x0.5

16/0.20

0.45

1.1

12.8

39

LiYY TP 10x2x0.5

16/0.20

0.45

1.2

14.7

39

LiYY TP 12x2x0.5

16/0.20

0.45

1.2

15

39

LiYY TP 15x2x0.5

16/0.20

0.45

1.3

16.7

39

0.75mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.75

24/0.20

0.5

0.6

5.4

26

LiYY TP 2x2x0.75

24/0.20

0.5

0.7

8.6

26

LiYY TP 3x2x0.75

24/0.20

0.5

0.8

9.5

26

LiYY TP 4x2x0.75

24/0.20

0.5

0.9

10.4

26

LiYY TP 6x2x0.75

24/0.20

0.5

1

12.7

26

LiYY TP 8x2x0.75

24/0.20

0.5

1.1

14.5

26

LiYY TP 10x2x0.75

24/0.20

0.5

1.2

16.7

26

LiYY TP 12x2x0.75

24/0.20

0.5

1.3

17.6

26

LiYY TP 15x2x0.75

24/0.20

0.5

1.4

19.6

26

1.0mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY TP 2x2x1.0

32/0.20

0.6

0.9

10.3

19.5

LiYY TP 3x2x1.0

32/0.20

0.6

1

11.4

19.5

LiYY TP 4x2x1.0

32/0.20

0.6

1

12.3

19.5

LiYY TP 6x2x1.0

32/0.20

0.6

1.2

15.2

19.5

LiYY TP 8x2x1.0

32/0.20

0.6

1.3

16.6

19.5

LiYY TP 10x2x1.0

32/0.20

0.6

1.4

19.8

19.5

1.5mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY TP 2x2x1.5

30/0.25

0.6

1

11.5

13.3

LiYY TP 3x2x1.5

30/0.25

0.6

1.1

12.7

13.3

LiYY TP 4x2x1.5

30/0.25

0.6

1.2

13.9

13.3

LiYY TP 6x2x1.5

30/0.25

0.6

1.3

16.9

13.3

LiYY TP 8x2x1.5

30/0.25

0.6

1.3

18.3

13.3


Product detail pictures:

Best Price On Irrigation Control Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures

Best Price On Irrigation Control Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures


Related Product Guide:

We emphasize advancement and introduce new products into the market each year for Best Price On Irrigation Control Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Turin, Juventus, belarus, With the spirit of "credit first, development through innovation, sincere cooperation and joint growth", our company is striving to create a brilliant future with you, so as to become a most valuable platform for exporting our products in China!
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Annie from Argentina - 2018.08.12 12:27
    In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Klemen Hrovat from Karachi - 2017.12.19 11:10
    Write your message here and send it to us