We have now a skilled, performance group to offer excellent support for our consumer. We usually follow the tenet of customer-oriented, details-focused for Structured Cabling Systems, Cat5e Ethernet Cable, 8way Pdu, We keep on with supplying integration alternatives for customers and hope to create long-term, steady, sincere and mutual advantageous interactions with consumers. We sincerely anticipate your check out.
Bottom Price Loudspeaker Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.14

12/0.12

0.35

0.4

3.2

148

LiYY 3×0.14

12/0.12

0.35

0.4

3.5

148

LiYY 4×0.14

12/0.12

0.35

0.5

3.9

148

LiYY 5×0.14

12/0.12

0.35

0.5

4.3

148

LiYY 7×0.14

12/0.12

0.35

0.6

4.8

148

LiYY 8×0.14

12/0.12

0.35

0.6

5.2

148

LiYY 10×0.14

12/0.12

0.35

0.7

6.2

148

LiYY 12×0.14

12/0.12

0.35

0.7

6.5

148

LiYY 14×0.14

12/0.12

0.35

0.7

6.7

148

0.25mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY 3×0.25

14/0.15

0.4

0.4

3.9

79.9

LiYY 4×0.25

14/0.15

0.4

0.5

4.4

79.9

LiYY 5×0.25

14/0.15

0.4

0.5

4.8

79.9

LiYY 7×0.25

14/0.15

0.4

0.6

5.4

79.9

LiYY 8×0.25

14/0.15

0.4

0.6

5.8

79.9

LiYY 10×0.25

14/0.15

0.4

0.7

7

79.9

LiYY 12×0.25

14/0.15

0.4

0.7

7.3

79.9

LiYY 14×0.25

14/0.15

0.4

0.7

7.6

79.9

0.34mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.34

20/0.15

0.4

0.5

4.2

57

LiYY 3×0.34

20/0.15

0.4

0.5

4.5

57

LiYY 4×0.34

20/0.15

0.4

0.6

5.1

57

LiYY 5×0.34

20/0.15

0.4

0.6

5.5

57

LiYY 7×0.34

20/0.15

0.4

0.7

6.2

57

LiYY 8×0.34

20/0.15

0.4

0.7

6.7

57

LiYY 10×0.34

20/0.15

0.4

0.8

8

57

LiYY 12×0.34

20/0.15

0.4

0.8

8.3

57

LiYY 14×0.34

20/0.15

0.4

0.8

8.7

57

0.50mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.5

16/0.20

0.45

0.6

4.8

39

LiYY 3×0.5

16/0.20

0.45

0.6

5.2

39

LiYY 4×0.5

16/0.20

0.45

0.6

5.6

39

LiYY 5×0.5

16/0.20

0.45

0.6

6.1

39

LiYY 7×0.5

16/0.20

0.45

0.6

6.6

39

LiYY 8×0.5

16/0.20

0.45

0.7

7.4

39

LiYY 10×0.5

16/0.20

0.45

0.7

8.6

39

LiYY 12×0.5

16/0.20

0.45

0.8

9.2

39

LiYY 14×0.5

16/0.20

0.45

0.9

9.8

39

0.75mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×0.75

24/0.20

0.5

0.6

5.4

26

LiYY 3×0.75

24/0.20

0.5

0.6

5.8

26

LiYY 4×0.75

24/0.20

0.5

0.6

6.3

26

LiYY 5×0.75

24/0.20

0.5

0.7

7.1

26

LiYY 7×0.75

24/0.20

0.5

0.7

7.7

26

LiYY 8×0.75

24/0.20

0.5

0.8

8.6

26

LiYY 10×0.75

24/0.20

0.5

0.8

10

26

LiYY 12×0.75

24/0.20

0.5

0.9

10.6

26

LiYY 14×0.75

24/0.20

0.5

1

11.3

26

1.0mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY 3×1.0

32/0.20

0.6

0.6

6.7

19.5

LiYY 4×1.0

32/0.20

0.6

0.7

7.5

19.5

LiYY 5×1.0

32/0.20

0.6

0.7

8.2

19.5

LiYY 7×1.0

32/0.20

0.6

0.8

9.1

19.5

1.5mm2

No. of Cores

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY 2×1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY 3×1.5

30/0.25

0.6

0.7

7.6

13.3

LiYY 4×1.5

30/0.25

0.6

0.7

8.2

13.3

LiYY 5×1.5

30/0.25

0.6

0.8

9.2

13.3

LiYY 7×1.5

30/0.25

0.6

0.9

10.5

13.3


Product detail pictures:

Bottom Price Loudspeaker Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures

Bottom Price Loudspeaker Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC)  – AIPU detail pictures


Related Product Guide:

abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for Bottom Price Loudspeaker Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Philippines, Georgia, Pakistan, We also have good cooperation relationships with many good manufacturers so that we can provide almost all of auto parts and after-sales service with high quality standard,lower price level and warmly service to meet demands of customers from different fields and different area.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Betty from Macedonia - 2018.07.27 12:26
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Yannick Vergoz from Armenia - 2017.08.28 16:02
    Write your message here and send it to us