Cheap Pricelist For Cy Cable - LiYcY Screened Multicore Control Cable – AIPU
Cheap Pricelist For Cy Cable - LiYcY Screened Multicore Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC
Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×0.14 |
12/0.12 |
0.35 |
0.7 |
4.4 |
148 |
LiYcY 3×0.14 |
12/0.12 |
0.35 |
0.7 |
4.7 |
148 |
LiYcY 4×0.14 |
12/0.12 |
0.35 |
0.7 |
4.9 |
148 |
LiYcY 5×0.14 |
12/0.12 |
0.35 |
0.7 |
5.3 |
148 |
LiYcY 7×0.14 |
12/0.12 |
0.35 |
0.7 |
5.6 |
148 |
LiYcY 8×0.14 |
12/0.12 |
0.35 |
0.8 |
6.2 |
148 |
LiYcY 10×0.14 |
12/0.12 |
0.35 |
0.8 |
7 |
148 |
LiYcY 12×0.14 |
12/0.12 |
0.35 |
0.8 |
7.3 |
148 |
LiYcY 14×0.14 |
12/0.12 |
0.35 |
0.8 |
7.5 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×0.25 |
14/0.15 |
0.4 |
0.7 |
4.8 |
79.9 |
LiYcY 3×0.25 |
14/0.15 |
0.4 |
0.7 |
5.1 |
79.9 |
LiYcY 4×0.25 |
14/0.15 |
0.4 |
0.7 |
5.4 |
79.9 |
LiYcY 5×0.25 |
14/0.15 |
0.4 |
0.7 |
5.8 |
79.9 |
LiYcY 7×0.25 |
14/0.15 |
0.4 |
0.8 |
6.4 |
79.9 |
LiYcY 8×0.25 |
14/0.15 |
0.4 |
0.8 |
6.8 |
79.9 |
LiYcY 10×0.25 |
14/0.15 |
0.4 |
0.8 |
7.8 |
79.9 |
LiYcY 12×0.25 |
14/0.15 |
0.4 |
0.8 |
8.1 |
79.9 |
LiYcY 14×0.25 |
14/0.15 |
0.4 |
0.8 |
8.2 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×0.34 |
20/0.15 |
0.4 |
0.7 |
5.2 |
57 |
LiYcY 3×0.34 |
20/0.15 |
0.4 |
0.7 |
5.5 |
57 |
LiYcY 4×0.34 |
20/0.15 |
0.4 |
0.7 |
5.9 |
57 |
LiYcY 5×0.34 |
20/0.15 |
0.4 |
0.7 |
6.3 |
57 |
LiYcY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.8 |
57 |
LiYcY 8×0.34 |
20/0.15 |
0.4 |
0.8 |
7.5 |
57 |
LiYcY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8.6 |
57 |
LiYcY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
9.1 |
57 |
LiYcY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
9.5 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×0.5 |
16/0.20 |
0.45 |
0.7 |
5.6 |
39 |
LiYcY 3×0.5 |
16/0.20 |
0.45 |
0.7 |
6 |
39 |
LiYcY 4×0.5 |
16/0.20 |
0.45 |
0.7 |
6.4 |
39 |
LiYcY 5×0.5 |
16/0.20 |
0.45 |
0.7 |
6.9 |
39 |
LiYcY 7×0.5 |
16/0.20 |
0.45 |
0.8 |
7.6 |
39 |
LiYcY 8×0.5 |
16/0.20 |
0.45 |
0.8 |
8.2 |
39 |
LiYcY 10×0.5 |
16/0.20 |
0.45 |
0.8 |
9.8 |
39 |
LiYcY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
10.2 |
39 |
LiYcY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
10.6 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×0.75 |
24/0.20 |
0.5 |
0.8 |
6.4 |
26 |
LiYcY 3×0.75 |
24/0.20 |
0.5 |
0.8 |
6.8 |
26 |
LiYcY 4×0.75 |
24/0.20 |
0.5 |
0.8 |
7.3 |
26 |
LiYcY 5×0.75 |
24/0.20 |
0.5 |
0.8 |
7.9 |
26 |
LiYcY 7×0.75 |
24/0.20 |
0.5 |
0.8 |
8.5 |
26 |
LiYcY 8×0.75 |
24/0.20 |
0.5 |
0.9 |
9.4 |
26 |
LiYcY 10×0.75 |
24/0.20 |
0.5 |
0.9 |
11 |
26 |
LiYcY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
11.4 |
26 |
LiYcY 14×0.75 |
24/0.20 |
0.5 |
1 |
12.1 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×1.0 |
32/0.20 |
0.6 |
0.8 |
7.2 |
19.5 |
LiYcY 3×1.0 |
32/0.20 |
0.6 |
0.8 |
7.7 |
19.5 |
LiYcY 4×1.0 |
32/0.20 |
0.6 |
0.8 |
8.3 |
19.5 |
LiYcY 5×1.0 |
32/0.20 |
0.6 |
0.8 |
9.2 |
19.5 |
LiYcY 7×1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYcY 2×1.5 |
30/0.25 |
0.6 |
0.8 |
7.8 |
13.3 |
LiYcY 3×1.5 |
30/0.25 |
0.6 |
0.8 |
8.4 |
13.3 |
LiYcY 4×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYcY 5×1.5 |
30/0.25 |
0.6 |
0.9 |
10.2 |
13.3 |
LiYcY 7×1.5 |
30/0.25 |
0.6 |
1 |
11 |
13.3 |
Product detail pictures:
Related Product Guide:
We always work as a tangible team to ensure that we can provide you with the best quality and the best price for Cheap Pricelist For Cy Cable - LiYcY Screened Multicore Control Cable – AIPU , The product will supply to all over the world, such as: Cyprus, Ukraine, Manchester, Good quality and reasonable price have brought us stable customers and high reputation. Providing 'Quality Products, Excellent Service, Competitive Prices and Prompt Delivery', we are now looking forward to even greater cooperation with overseas customers based on mutual benefits. We'll work whole-heartedly to improve our solutions and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.
By Modesty from Luxemburg - 2018.07.12 12:19
This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
By mary rash from kazakhstan - 2018.09.12 17:18