We aim to find out quality disfigurement from the production and supply the best service to domestic and overseas customers wholeheartedly for Fiber Keystone Jack, Control Cable, Heat Trace Cable, In a word, when you choose us, you choose a ideal life. Welcome to go to our manufacturing unit and welcome your get! For further more inquiries, remember to usually do not be reluctant to get in touch with us.
Excellent Quality Solid Cat6 Cable - LiYY TP Multipair Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.14

12/0.12

0.35

0.4

3.2

148

LiYY TP 2x2x0.14

12/0.12

0.35

0.6

5.3

148

LiYY TP 3x2x0.14

12/0.12

0.35

0.6

5.7

148

LiYY TP 4x2x0.14

12/0.12

0.35

0.7

6.4

148

LiYY TP 6x2x0.14

12/0.12

0.35

0.7

7.5

148

LiYY TP 8x2x0.14

12/0.12

0.35

0.8

8.6

148

LiYY TP 10x2x0.14

12/0.12

0.35

0.9

10

148

LiYY TP 12x2x0.14

12/0.12

0.35

1

10.4

148

LiYY TP 15x2x0.14

12/0.12

0.35

1.1

11.6

148

0.25mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY TP 2x2x0.25

14/0.15

0.4

0.6

6

79.9

LiYY TP 3x2x0.25

14/0.15

0.4

0.6

6.4

79.9

LiYY TP 4x2x0.25

14/0.15

0.4

0.7

7.2

79.9

LiYY TP 6x2x0.25

14/0.15

0.4

0.8

8.8

79.9

LiYY TP 8x2x0.25

14/0.15

0.4

0.8

9.8

79.9

LiYY TP 10x2x0.25

14/0.15

0.4

1

11.5

79.9

LiYY TP 12x2x0.25

14/0.15

0.4

1

12.1

79.9

LiYY TP 15x2x0.25

14/0.15

0.4

1.1

13.5

79.9

0.34mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.34

20/0.15

0.4

0.5

4.2

57

LiYY TP 2x2x0.34

20/0.15

0.4

0.6

6.7

57

LiYY TP 3x2x0.34

20/0.15

0.4

0.6

7.2

57

LiYY TP 4x2x0.34

20/0.15

0.4

0.7

8

57

LiYY TP 6x2x0.34

20/0.15

0.4

0.9

10

57

LiYY TP 8x2x0.34

20/0.15

0.4

1

11.4

57

LiYY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYY TP 12x2x0.34

20/0.15

0.4

1.1

13.4

57

LiYY TP 15x2x0.34

20/0.15

0.4

1.2

14.9

57

0.50mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.5

16/0.20

0.45

0.6

4.8

39

LiYY TP 2x2x0.5

16/0.20

0.45

0.7

7.5

39

LiYY TP 3x2x0.5

16/0.20

0.45

0.7

8.1

39

LiYY TP 4x2x0.5

16/0.20

0.45

0.8

9

39

LiYY TP 6x2x0.5

16/0.20

0.45

1

11.2

39

LiYY TP 8x2x0.5

16/0.20

0.45

1.1

12.8

39

LiYY TP 10x2x0.5

16/0.20

0.45

1.2

14.7

39

LiYY TP 12x2x0.5

16/0.20

0.45

1.2

15

39

LiYY TP 15x2x0.5

16/0.20

0.45

1.3

16.7

39

0.75mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.75

24/0.20

0.5

0.6

5.4

26

LiYY TP 2x2x0.75

24/0.20

0.5

0.7

8.6

26

LiYY TP 3x2x0.75

24/0.20

0.5

0.8

9.5

26

LiYY TP 4x2x0.75

24/0.20

0.5

0.9

10.4

26

LiYY TP 6x2x0.75

24/0.20

0.5

1

12.7

26

LiYY TP 8x2x0.75

24/0.20

0.5

1.1

14.5

26

LiYY TP 10x2x0.75

24/0.20

0.5

1.2

16.7

26

LiYY TP 12x2x0.75

24/0.20

0.5

1.3

17.6

26

LiYY TP 15x2x0.75

24/0.20

0.5

1.4

19.6

26

1.0mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY TP 2x2x1.0

32/0.20

0.6

0.9

10.3

19.5

LiYY TP 3x2x1.0

32/0.20

0.6

1

11.4

19.5

LiYY TP 4x2x1.0

32/0.20

0.6

1

12.3

19.5

LiYY TP 6x2x1.0

32/0.20

0.6

1.2

15.2

19.5

LiYY TP 8x2x1.0

32/0.20

0.6

1.3

16.6

19.5

LiYY TP 10x2x1.0

32/0.20

0.6

1.4

19.8

19.5

1.5mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY TP 2x2x1.5

30/0.25

0.6

1

11.5

13.3

LiYY TP 3x2x1.5

30/0.25

0.6

1.1

12.7

13.3

LiYY TP 4x2x1.5

30/0.25

0.6

1.2

13.9

13.3

LiYY TP 6x2x1.5

30/0.25

0.6

1.3

16.9

13.3

LiYY TP 8x2x1.5

30/0.25

0.6

1.3

18.3

13.3


Product detail pictures:

Excellent Quality Solid Cat6 Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures

Excellent Quality Solid Cat6 Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures


Related Product Guide:

We've been commitment to offer the competitive rate ,outstanding merchandise good quality, too as fast delivery for Excellent Quality Solid Cat6 Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Botswana, Malta, Colombia, We insist on the principle of "Credit being primary, Customers being the king and Quality being the best", we are looking forward to the mutual cooperation with all friends at home and abroad and we will create a bright future of business.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Joanne from Italy - 2018.04.25 16:46
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Honorio from Saudi Arabia - 2017.01.28 19:59
    Write your message here and send it to us