Factory Cheap Hot Pvc Network Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Factory Cheap Hot Pvc Network Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY 3×0.14 |
12/0.12 |
0.35 |
0.4 |
3.5 |
148 |
LiYY 4×0.14 |
12/0.12 |
0.35 |
0.5 |
3.9 |
148 |
LiYY 5×0.14 |
12/0.12 |
0.35 |
0.5 |
4.3 |
148 |
LiYY 7×0.14 |
12/0.12 |
0.35 |
0.6 |
4.8 |
148 |
LiYY 8×0.14 |
12/0.12 |
0.35 |
0.6 |
5.2 |
148 |
LiYY 10×0.14 |
12/0.12 |
0.35 |
0.7 |
6.2 |
148 |
LiYY 12×0.14 |
12/0.12 |
0.35 |
0.7 |
6.5 |
148 |
LiYY 14×0.14 |
12/0.12 |
0.35 |
0.7 |
6.7 |
148 |
0.25mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY 3×0.25 |
14/0.15 |
0.4 |
0.4 |
3.9 |
79.9 |
LiYY 4×0.25 |
14/0.15 |
0.4 |
0.5 |
4.4 |
79.9 |
LiYY 5×0.25 |
14/0.15 |
0.4 |
0.5 |
4.8 |
79.9 |
LiYY 7×0.25 |
14/0.15 |
0.4 |
0.6 |
5.4 |
79.9 |
LiYY 8×0.25 |
14/0.15 |
0.4 |
0.6 |
5.8 |
79.9 |
LiYY 10×0.25 |
14/0.15 |
0.4 |
0.7 |
7 |
79.9 |
LiYY 12×0.25 |
14/0.15 |
0.4 |
0.7 |
7.3 |
79.9 |
LiYY 14×0.25 |
14/0.15 |
0.4 |
0.7 |
7.6 |
79.9 |
0.34mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY 3×0.34 |
20/0.15 |
0.4 |
0.5 |
4.5 |
57 |
LiYY 4×0.34 |
20/0.15 |
0.4 |
0.6 |
5.1 |
57 |
LiYY 5×0.34 |
20/0.15 |
0.4 |
0.6 |
5.5 |
57 |
LiYY 7×0.34 |
20/0.15 |
0.4 |
0.7 |
6.2 |
57 |
LiYY 8×0.34 |
20/0.15 |
0.4 |
0.7 |
6.7 |
57 |
LiYY 10×0.34 |
20/0.15 |
0.4 |
0.8 |
8 |
57 |
LiYY 12×0.34 |
20/0.15 |
0.4 |
0.8 |
8.3 |
57 |
LiYY 14×0.34 |
20/0.15 |
0.4 |
0.8 |
8.7 |
57 |
0.50mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY 3×0.5 |
16/0.20 |
0.45 |
0.6 |
5.2 |
39 |
LiYY 4×0.5 |
16/0.20 |
0.45 |
0.6 |
5.6 |
39 |
LiYY 5×0.5 |
16/0.20 |
0.45 |
0.6 |
6.1 |
39 |
LiYY 7×0.5 |
16/0.20 |
0.45 |
0.6 |
6.6 |
39 |
LiYY 8×0.5 |
16/0.20 |
0.45 |
0.7 |
7.4 |
39 |
LiYY 10×0.5 |
16/0.20 |
0.45 |
0.7 |
8.6 |
39 |
LiYY 12×0.5 |
16/0.20 |
0.45 |
0.8 |
9.2 |
39 |
LiYY 14×0.5 |
16/0.20 |
0.45 |
0.9 |
9.8 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY 3×0.75 |
24/0.20 |
0.5 |
0.6 |
5.8 |
26 |
LiYY 4×0.75 |
24/0.20 |
0.5 |
0.6 |
6.3 |
26 |
LiYY 5×0.75 |
24/0.20 |
0.5 |
0.7 |
7.1 |
26 |
LiYY 7×0.75 |
24/0.20 |
0.5 |
0.7 |
7.7 |
26 |
LiYY 8×0.75 |
24/0.20 |
0.5 |
0.8 |
8.6 |
26 |
LiYY 10×0.75 |
24/0.20 |
0.5 |
0.8 |
10 |
26 |
LiYY 12×0.75 |
24/0.20 |
0.5 |
0.9 |
10.6 |
26 |
LiYY 14×0.75 |
24/0.20 |
0.5 |
1 |
11.3 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY 3×1.0 |
32/0.20 |
0.6 |
0.6 |
6.7 |
19.5 |
LiYY 4×1.0 |
32/0.20 |
0.6 |
0.7 |
7.5 |
19.5 |
LiYY 5×1.0 |
32/0.20 |
0.6 |
0.7 |
8.2 |
19.5 |
LiYY 7×1.0 |
32/0.20 |
0.6 |
0.8 |
9.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY 2×1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY 3×1.5 |
30/0.25 |
0.6 |
0.7 |
7.6 |
13.3 |
LiYY 4×1.5 |
30/0.25 |
0.6 |
0.7 |
8.2 |
13.3 |
LiYY 5×1.5 |
30/0.25 |
0.6 |
0.8 |
9.2 |
13.3 |
LiYY 7×1.5 |
30/0.25 |
0.6 |
0.9 |
10.5 |
13.3 |
Product detail pictures:
Related Product Guide:
"Control the standard by the details, show the power by quality". Our organization has strived to establish a highly efficient and stable employees team and explored an effective high-quality command method for Factory Cheap Hot Pvc Network Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU , The product will supply to all over the world, such as: Sydney, Bangladesh, Cape Town, We adhere to the honest, efficient, practical win-win running mission and people-oriented business philosophy. Excellent quality, reasonable price and customer satisfaction are always pursued! If you are interested in our products, just try to contact us for more details!