Adhering into the theory of "quality, services, efficiency and growth", now we have gained trusts and praises from domestic and international shopper for Solid Strand Wire, Data And Power Cable, 4 Pair Twisted Cable, We welcome new and old customers from all walks of life to contact us for future business relationships and achieve mutual success!
Factory Directly Supply Sy Control Cable - LiYcY TP Multipair Screened Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR at
20℃ (Ω/km)

LiYcY TP 1x2x0.14

12/0.12

0.35

0.7

4.4

148

LiYcY TP 2x2x0.14

12/0.12

0.35

0.7

6.1

148

LiYcY TP 3x2x0.14

12/0.12

0.35

0.8

6.7

148

LiYcY TP 4x2x0.14

12/0.12

0.35

0.8

7.2

148

LiYcY TP 6x2x0.14

12/0.12

0.35

0.8

8.3

148

LiYcY TP 8x2x0.14

12/0.12

0.35

0.8

9.4

148

LiYcY TP 10x2x0.14

12/0.12

0.35

0.9

10.8

148

LiYcY TP 12x2x0.14

12/0.12

0.35

1.0

11.4

148

0.25mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.25

14/0.15

0.4

0.7

4.8

79.9

LiYcY TP 2x2x0.25

14/0.15

0.4

0.8

7

79.9

LiYcY TP 3x2x0.25

14/0.15

0.4

0.8

7.4

79.9

LiYcY TP 4x2x0.25

14/0.15

0.4

0.8

8

79.9

LiYcY TP 6x2x0.25

14/0.15

0.4

0.8

9.6

79.9

LiYcY TP 8x2x0.25

14/0.15

0.4

0.9

10.8

79.9

LiYcY TP 10x2x0.25

14/0.15

0.4

1.0

12.3

79.9

LiYcY TP 12x2x0.25

14/0.15

0.4

1.1

12.6

79.9

0.34mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.34

20/0.15

0.4

0.7

5.2

57

LiYcY TP 2x2x0.34

20/0.15

0.4

0.8

7.7

57

LiYcY TP 3x2x0.34

20/0.15

0.4

0.8

8.2

57

LiYcY TP 4x2x0.34

20/0.15

0.4

0.8

9

57

LiYcY TP 6x2x0.34

20/0.15

0.4

0.9

10.8

57

LiYcY TP 8x2x0.34

20/0.15

0.4

1.0

12.2

57

LiYcY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYcY TP 12x2x0.34

20/0.15

0.4

1.2

14.7

57

0.50mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.5

16/0.20

0.45

0.7

5.6

39

LiYcY TP 2x2x0.5

16/0.20

0.45

0.8

8.3

39

LiYcY TP 3x2x0.5

16/0.20

0.45

0.8

9.1

39

LiYcY TP 4x2x0.5

16/0.20

0.45

0.9

10

39

LiYcY TP 6x2x0.5

16/0.20

0.45

1.0

12

39

LiYcY TP 8x2x0.5

16/0.20

0.45

1.1

13.1

39

LiYcY TP 10x2x0.5

16/0.20

0.45

1.2

15.5

39

0.75mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.75

24/0.20

0.5

0.8

6.4

26

LiYcY TP 2x2x0.75

24/0.20

0.5

0.8

9.6

26

LiYcY TP 3x2x0.75

24/0.20

0.5

0.9

10.5

26

LiYcY TP 4x2x0.75

24/0.20

0.5

1.0

11.4

26

LiYcY TP 6x2x0.75

24/0.20

0.5

1.1

13.7

26

LiYcY TP 8x2x0.75

24/0.20

0.5

1.2

15

26

LiYcY TP 10x2x0.75

24/0.20

0.5

1.3

17.7

26

1.0mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.0

32/0.20

0.6

0.8

7.2

19.5

LiYcY TP 2x2x1.0

32/0.20

0.6

0.9

11.1

19.5

LiYcY TP 3x2x1.0

32/0.20

0.6

1.0

12.2

19.5

LiYcY TP 4x2x1.0

32/0.20

0.6

1.0

13.1

19.5

LiYcY TP 6x2x1.0

32/0.20

0.6

1.2

15

19.5

LiYcY TP 8x2x1.0

32/0.20

0.6

1.3

17.4

19.5

1.5mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.5

30/0.25

0.6

0.8

7.8

13.3

LiYcY TP 2x2x1.5

30/0.25

0.6

1.0

12.3

13.3

LiYcY TP 3x2x1.5

30/0.25

0.6

1.1

13.5

13.3

LiYcY TP 4x2x1.5

30/0.25

0.6

1.2

14.7

13.3


Product detail pictures:

Factory Directly Supply Sy Control Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures

Factory Directly Supply Sy Control Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Factory Directly Supply Sy Control Cable - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: Libya, Leicester, Oman, With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we're trying our best to be your good partner.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Janice from Bolivia - 2018.09.21 11:01
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Klemen Hrovat from Kuwait - 2018.11.06 10:04
    Write your message here and send it to us