We are ready to share our knowledge of marketing worldwide and recommend you suitable products at most aggressive costs. So Profi Tools offer you finest benefit of money and we are ready to produce alongside one another with Outdoor Lan Cable, Deep Server Rack, 4 Wire Data Cable, Together with our efforts, our products have won the trust of customers and been very salable both here and abroad.
Factory Free Sample Genesis Access Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
4. Screen: Tinned Copper Wire Braided
5. Sheath: LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.14

12/0.12

0.3

0.6

4

148

LiHcH 3×0.14

12/0.12

0.3

0.6

4.2

148

LiHcH 4×0.14

12/0.12

0.3

0.6

4.5

148

LiHcH 5×0.14

12/0.12

0.3

0.6

4.8

148

LiHcH 7×0.14

12/0.12

0.3

0.6

5.1

148

LiHcH 8×0.14

12/0.12

0.3

0.6

5.4

148

LiHcH 10×0.14

12/0.12

0.3

0.6

6.2

148

LiHcH 12×0.14

12/0.12

0.3

0.7

6.6

148

LiHcH 14×0.14

12/0.12

0.3

0.7

6.9

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHcH 3×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHcH 4×0.25

14/0.15

0.3

0.6

5

79.9

LiHcH 5×0.25

14/0.15

0.3

0.6

5.3

79.9

LiHcH 7×0.25

14/0.15

0.3

0.6

5.7

79.9

LiHcH 8×0.25

14/0.15

0.3

0.6

6.1

79.9

LiHcH 10×0.25

14/0.15

0.3

0.7

7.2

79.9

LiHcH 12×0.25

14/0.15

0.3

0.7

7.5

79.9

LiHcH 14×0.25

14/0.15

0.3

0.7

7.8

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.34

20/0.15

0.3

0.6

4.6

57

LiHcH 3×0.34

20/0.15

0.3

0.6

4.9

57

LiHcH 4×0.34

20/0.15

0.3

0.6

5.2

57

LiHcH 5×0.34

20/0.15

0.3

0.6

5.6

57

LiHcH 7×0.34

20/0.15

0.3

0.6

6

57

LiHcH 8×0.34

20/0.15

0.3

0.6

6.4

57

LiHcH 10×0.34

20/0.15

0.3

0.7

7.6

57

LiHcH 12×0.34

20/0.15

0.3

0.7

7.9

57

LiHcH 14×0.34

20/0.15

0.3

0.7

8.2

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.5

16/0.20

0.3

0.6

4.9

39

LiHcH 3×0.5

16/0.20

0.3

0.6

5.2

39

LiHcH 4×0.5

16/0.20

0.3

0.6

5.6

39

LiHcH 5×0.5

16/0.20

0.3

0.6

6

39

LiHcH 7×0.5

16/0.20

0.3

0.6

6.5

39

LiHcH 8×0.5

16/0.20

0.3

0.7

7.1

39

LiHcH 10×0.5

16/0.20

0.3

0.7

8.2

39

LiHcH 12×0.5

16/0.20

0.3

0.7

8.7

39

LiHcH 14×0.5

16/0.20

0.3

0.7

9.1

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.75

24/0.20

0.4

0.6

5.8

26

LiHcH 3×0.75

24/0.20

0.4

0.6

6.2

26

LiHcH 4×0.75

24/0.20

0.4

0.6

6.7

26

LiHcH 5×0.75

24/0.20

0.4

0.7

7.2

26

LiHcH 7×0.75

24/0.20

0.4

0.7

7.8

26

LiHcH 8×0.75

24/0.20

0.4

0.7

8.8

26

LiHcH 10×0.75

24/0.20

0.4

0.8

10.4

26

LiHcH 12×0.75

24/0.20

0.4

0.8

10.8

26

LiHcH 14×0.75

24/0.20

0.4

0.9

11.5

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.0

32/0.20

0.5

0.6

6.4

19.5

LiHcH 3×1.0

32/0.20

0.5

0.6

6.9

19.5

LiHcH 4×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHcH 5×1.0

32/0.20

0.5

0.7

8.2

19.5

LiHcH 7×1.0

32/0.20

0.5

0.9

9.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.5

30/0.25

0.5

0.6

7

13.3

LiHcH 3×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHcH 4×1.5

30/0.25

0.5

0.7

8.3

13.3

LiHcH 5×1.5

30/0.25

0.5

0.8

9.4

13.3

LiHcH 7×1.5

30/0.25

0.5

1.0

10.6

13.3


Product detail pictures:

Factory Free Sample Genesis Access Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures

Factory Free Sample Genesis Access Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures


Related Product Guide:

Our primary objective is usually to offer our shoppers a serious and responsible small business relationship, offering personalized attention to all of them for Factory Free Sample Genesis Access Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU , The product will supply to all over the world, such as: Montreal, Czech, Turkmenistan, With many years good service and development, we've a professional international trade sales team. Our products have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!
  • This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Kay from Vietnam - 2018.05.22 12:13
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Karen from Atlanta - 2017.06.25 12:48
    Write your message here and send it to us