About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Wholesale Discount Liyy Control Cable - PROFINET Cable Type A 1x2x22AWG by (PROFIBUS International) – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1) 2. Insulation: S-PE 3. Identification: White, Yellow, Blue, Orange 4. Cabling: Star Quad 5. Inner Sheath: PVC/LSZH 6. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 7. Outer Sheath: PVC/LSZH 8. Sheath: Green Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives...
inquiry
detail
Manufacturing Companies for Keystone Insert - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Manufactur Standard Electric Drum Cables - Schneider (Modicon) MODBUS Cable 3x2x22AWG – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-PE, S-PP 3. Identification: Color Coded 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Electrical Performance Working Voltage 300V Test Voltage 1.0KV Velocity of Propagatio...
inquiry
detail
New Delivery for Network Outlet - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
inquiry
detail
Hot Sale Factory Yy Cable - Foundation Fieldbus Type A Cable 18~14AWG – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: Polyolefin 3. Identification: Blue, Orange 4. Screen: Individual & Overall Screen 5. Sheath: PVC/LSZH 6. Sheath: Yellow Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Cond...
inquiry
detail
Oem/Odm China Shielded Cat6a Cable - 309Y PVC Cable 90C 2-5 CORES 300/500V H05V2V2-F – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC 3. Identification: 2 Cores: Blue & Brown 3 Core: Green/Yellow, Blue & Brown 4 Core: Green/Yellow, Brown, Black & Grey 5 Core: Green/Yellow, Brown, Black Grey & Blue 4. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 90ºC Rated Voltage: 300/500V Test Voltage: 2000V Reference Standards BS6500 BS EN 50525-2-11 BS EN 60228 BS EN...
inquiry
detail
New Arrival China Network Cabling Companies - Cat.6A Network Unshielded 24-Port Patch Panel – AIPU
Product Quality Product quality is essential to a reliable network. AIPU’s CAT6A patch panel meets TIA/EIA 568A & 568B standards. The RJ45 ports mount flush against the panel’s face which helps eliminate cable snags and create a professional aesthetic. This CAT6A Patch Panel is not only ideal for speed and efficiency but also great for cable organization. Durability & Strength To ensure our CAT6 Patch Panel’s durability and strength, we use SPCC 16 gauge st...
inquiry
detail
Low price for Data Cabinet Rack - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Best Price For Data Bus Cable - Automotive Control Cable Communication Cable Multipair RS232/RS422 Cable 24AWG for Production Process Control Device Converter – AIPU
Application 1. The cable is designed for EIA RS-232 or RS-422 applications, used as computer cables. Multi-pair cables are available. It could be widely used for production process control and Device Converter. 2. RS-232, RS-422 and RS-485 are all used for digital data transmission. The RS-232 standard is mainly used for COM ports or serial ports of ordinary computers. The RS-422 and RS-485 interfaces are mainly used to connect various devices in the industry. RS-232 and RS-422 transfer...
inquiry
detail
High Performance Open Server Rack - Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
Cheapest Price Instrumentation And Control Cable - LiYcY TP Multipair Screened Control Cable – AIPU
Constructions 1. Conductor: Class 5 Tinned Copper 2. Insulation: PVC 3. Identification: Colored 4. Cabling: Twisted Pair 5. Screen: Tinned Copper Wire Braided 6. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V ...
inquiry
detail
Chinese Wholesale Solid Cable - Audio, Control and Instrumentation Cables (Multi-Core, Screened) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-corer cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire,Tinned Copper Braided and Spiral are optional. 3. PVC or LSZH sheath are both available. 4. Aipu has employees about 2000people and among them 200 people are...
inquiry
detail
<<
< Previous
114
115
116
117
118
119
120
Next >
>>
Page 117 / 340