About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
High Performance Belden Althernative Cable - 318Y/B Cable 2-5 CORES PVC / LSZH 300/500V H05VV-F, H05Z1Z1-F – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC, LSZH 3. Identification: 2 Cores: Blue & Brown 3 Core: Green/Yellow, Blue & Brown 4 Core: Green/Yellow, Brown, Black & Grey 5 Core: Green/Yellow, Brown, Black Grey & Blue 4. Sheath: PVC, LSZH Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Bending Radius: 8 x overall diameter Rated Voltage: 300/500V Test Voltage: 2000V Reference Standards BS6500 BS EN...
inquiry
detail
Reasonable Price For Data Center Cable - KNX/EIB Building Automation Cable by EIB & EHS – AIPU
Constructions Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Cable Construction Part No. APYE00819 for PVC APYE00820 for PVC APYE00905 for LSZH APYE00906 for LSZH Structure 1x2x20AWG 2x2x20AWG Conductor Material Solid Oxygen Free Copper Conductor Size 0.80mm Insulation S-PE Id...
inquiry
detail
New Fashion Design For Lighting Control Cable - Siemens PROFIBUS PA Cable 1x2x18AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1) 2. Insulation: S-PE 3. Identification: Red, Green 4. Filler: Halogen Free Compound 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Blue (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN...
inquiry
detail
Free sample for Full Server Rack - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
Free sample for Full Server Rack - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
inquiry
detail
Oem/Odm Factory Building Wire Cable - Foundation Fieldbus Type B Cable – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-FPE 3. Identification: Blue, Orange 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH 7. Sheath: Orange Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Characteristic...
inquiry
detail
Leading Manufacturer for Utp Patch Cord - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
inquiry
detail
2021 High quality Data Cabling Systems - Cat6A Lan Cable S/FTP 4 Pair Copper Wire Ethernet Cable UTP Cable Solid Cable 305M Used In EMI – AIPU
Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class D | UL Subject 444 Description Aipu-waton CAT6A S/FTP Cable supports the CAT6A channel requirements ANSI/TIA-568.2-D and ISO/IEC 11801 Class D. It supports the 10GBASE-T up to 100m in channel length which ensures that it can support the fastest Ethernet applications. The cable has an overall Shielded plus each pair is also shielded. This type cable is made by individual foil shielded 4 pair copper wire an outer braid which could impro...
inquiry
detail
Cheap Pricelist For Cy Cable - LiHH Multicore Control Cable (Halogen Free) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 5. Sheath: LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1.0~1.5mm2 300/500V 3000V 200 0.14...
inquiry
detail
Professional Factory For Cat6 Ethernet Cable - Indoor Network Cable Lan Cable Audio Cable Multi-core Multi-Core Unscreened PVC Sheath LSZH for Production Process Control Device Converter Audio Instrument – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper or Tinned Copper 2. Insulation: Polyolefin 3. Cabling: Cores laying-up 4. Sheath: PVC/LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Identification of Insulation Operating Voltage 150V, 300V, 600V Test Voltage 1.0 KVdc Conductor DCR 57.0 Ω/km (Max. @ 20°C) for 22AWG 39.50 Ω/km (Max. @ 20°C) for 20AW...
inquiry
detail
Hot-selling Solid Core Copper Wire - Cat5E UTP 48 Port Tooless Patch Panel For Network Cabling – AIPU
Application:Cat.5e Unshielded Cabling System Features:Heavy duty/Easy cable management/numbered&labeled/punch down interface/Tooless installation Standard 38”, 2U height, loaded Reliable Performance 50μm Gold Plated pin for stable t ransmission Closed metal cover against EMI Rear Cable Management Jumper 1~48pcs patch cords RJ45 Lifetime: ≥750 IDC Lifetime: ≥250 Cat5 vs. Cat5E 1.1:Category 5e (Category 5 enhanced) Ethernet cables are newer than category 5 cables and support...
inquiry
detail
<<
< Previous
10
11
12
13
14
15
16
Next >
>>
Page 13 / 340