About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Low Moq For Burglar Alarm Cable - Single Core Non-sheathed Cable to EN50525-2-31 – AIPU
Constructions 1. Conductor: Class 1/2/5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification: Green/Yellow, Black, Blue, Brown, Red, White, Yellow, Grey, Violet, Grey, Orange, Pink Installation Temperature: Above 0ºC Operating Temperature: 70ºC, 90ºC Rated Voltage: 300/500V, 450/750V Test Voltage: 2000V, 2500V Reference Standards BS EN 50525-2-31 BS EN 60228 BS EN 50363 RoHS Directives IEC60332-1 Part No. Conductor Insulation Thickness (mm) Diameter (mm) Max. Res...
inquiry
detail
Renewable Design For Push Pull Control Cables - Foundation Fieldbus Type A Cable 18~14AWG – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: Polyolefin 3. Identification: Blue, Orange 4. Screen: Individual & Overall Screen 5. Sheath: PVC/LSZH 6. Sheath: Yellow Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Cond...
inquiry
detail
Factory Promotional Cat6a Ethernet Cable - LiHH Multicore Control Cable (Halogen Free) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 5. Sheath: LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1.0~1.5mm2 300/500V 3000V 200 0.14...
inquiry
detail
Factory Promotional Server Rack Height - Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
Factory Supply Tall Server Cabinet - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Factory Supplied Public Address Cable - 309Y PVC Cable 90C 2-5 CORES 300/500V H05V2V2-F – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC 3. Identification: 2 Cores: Blue & Brown 3 Core: Green/Yellow, Blue & Brown 4 Core: Green/Yellow, Brown, Black & Grey 5 Core: Green/Yellow, Brown, Black Grey & Blue 4. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 90ºC Rated Voltage: 300/500V Test Voltage: 2000V Reference Standards BS6500 BS EN 50525-2-11 BS EN 60228 BS EN...
inquiry
detail
Wholesale Dealers Of Data And Power Cable - Multipair Analog Audio Cable Shielded PVC / LSZH – AIPU
Application 1. The cable is designed for For analog audio transmission, used in connecting for audio appliances, small electric tools and instruments.Multi-pair cables are available. 2. Al-PET Tape & Tinned Copper Braid shielded could make the signal and date interference free. 3. PVC or LSZH sheath are both available. 4. Some people argue that analog music is better because of the purity of the sound, using analog connected analog devices is “natural.” Some people lik...
inquiry
detail
Factory best selling Server Rack Sliding Rails - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
inquiry
detail
Hot Sale Eib Cable - Electric Connect Wire Multicore Speaker Cable For Commercial Infrastructure Car Audio Home HiFi Cinema Speaker System – AIPU
Application 1. The cable is designed for loudspeaker application. It could be used for car audio, home HiFi, cinema, or speaker system with high-end cables for an unforgettable sound experience. 2. The three key electrical characteristics of a speaker cable are resistance, capacitance, and inductance. Of these, resistance is the most important. The speaker cable is the wire that connects the speaker to the amplifier source. 3. The resistance of loudspeaker is mainly affected by conduct...
inquiry
detail
Competitive Price For Unbalanced Instrument Cable - Echelon LonWorks Cable 1x2x22AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper 2. Insulation: S-PE, S-FPE 3. Identification: ● Pair 1: White, Blue ● Pair 2: White, Orange 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: LSZH 7. Sheath: White (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Reference Standards EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC...
inquiry
detail
Best Price for Keystone Jack Wall Plate - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Cheap Price Rj45 Patch Cable - Audio, Control and Instrumentation Cables (Multi-Core, Screened) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-corer cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire,Tinned Copper Braided and Spiral are optional. 3. PVC or LSZH sheath are both available. 4. Aipu has employees about 2000people and among them 200 people are...
inquiry
detail
<<
< Previous
146
147
148
149
150
151
152
Next >
>>
Page 149 / 340