Featured

  • Reliable Supplier Rack Mountable Server - Indoor Tight Buffered Fiber Optic Cable-GJFJV  – AIPU

    Reliable Supplier Rack Mountable Server - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
  • Oem/Odm Manufacturer Building Wire And Cable - ControlBus Cable 1 Pair for System Bus  – AIPU

    Oem/Odm Manufacturer Building Wire And Cable - ControlBus Cable 1 Pair for System Bus – AIPU

    Constructions 1. Conductor: Oxygen Free Copper or Tinned Copper Wire         2. Insulation: S-PE, S-FPE         3. Identification: Color Coded         4. Cabling: Twisted Pair         5. Screen:          ● Aluminium/Polyester Tape     ● Tinned Copper Wire Braided     6. Sheath: PVC/LSZH         (Note: Armor by Gavanized Steel Wire or Steel Tape is under request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Refere...
  • Chinese Professional 4 Pair Twisted Cable - LiYcY Screened Multicore Control Cable  – AIPU

    Chinese Professional 4 Pair Twisted Cable - LiYcY Screened Multicore Control Cable – AIPU

    Constructions 1. Conductor: Class 5 Tinned Copper 2. Insulation: PVC 3. Identification: Colored 4. Cabling: Twisted Pair 5. Screen: Tinned Copper Wire Braided 6. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 0.14mm2 No. of Cores Conductor Construction (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Max. DCR at 20℃ (Ω/km) LiYcY ...
  • High Quality Lszh Cat6 Cable - PROFINET Cable Type A 1x2x22AWG by (PROFIBUS International)  – AIPU

    High Quality Lszh Cat6 Cable - PROFINET Cable Type A 1x2x22AWG by (PROFIBUS International) – AIPU

    Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1)  2. Insulation: S-PE 3. Identification: White, Yellow, Blue, Orange  4. Cabling: Star Quad 5. Inner Sheath: PVC/LSZH 6. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 7. Outer Sheath: PVC/LSZH 8. Sheath: Green Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives...
  • Low Moq For Burglar Alarm Cable - Multipair Analog Audio Cable Shielded PVC / LSZH   – AIPU

    Low Moq For Burglar Alarm Cable - Multipair Analog Audio Cable Shielded PVC / LSZH – AIPU

    Application 1. The cable is designed for For analog audio transmission, used in connecting for audio appliances, small electric tools and instruments.Multi-pair cables are available. 2. Al-PET Tape & Tinned Copper Braid shielded could make the signal and date interference free. 3. PVC or LSZH sheath are both available. 4. Some people argue that analog music is better because of the purity of the sound, using analog connected analog devices is “natural.”  Some people lik...
  • China Factory for Network Panel Rack - Stranded loose tube direct buried or aerial optical Cable  – AIPU

    China Factory for Network Panel Rack - Stranded loose tube direct buried or aerial optical Cable – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
  • Manufacturer Of Crimping Data Cable - Bosch CAN Bus Cable 1 Pair 120ohm shielded  – AIPU

    Manufacturer Of Crimping Data Cable - Bosch CAN Bus Cable 1 Pair 120ohm shielded – AIPU

    Constructions 1. Conductor: Stranded Oxygen Free Copper. 2. Insulation: S-FPE. 3. Identification: 1 Pair: White, Brown. 1 Quad: White, Brown, Green, Yellow. 4. Wrapping    Polyester Tape. 5. Screen: Tinned Copper Wire Braided. 6. Sheath: PVC/LSZH. 7. Sheath: Violet. Reference Standards BS EN 60228 BS EN 50290 RoHS Directives  IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Electrical Performance ...
  • Cheapest Factory Server Rack Patch Panel - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards  – AIPU

    Cheapest Factory Server Rack Patch Panel - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
  • 2021 Wholesale Price Outdoor Ethernet Cable - Audio, Control and Instrumentation Cables (Multi-Core, Screened)  – AIPU

    2021 Wholesale Price Outdoor Ethernet Cable - Audio, Control and Instrumentation Cables (Multi-Core, Screened) – AIPU

    Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-corer cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire,Tinned Copper Braided and Spiral are optional. 3. PVC or LSZH sheath are both available. 4. Aipu has employees about 2000people and among them 200 people are...
  • High Reputation Lighting Cable - Multicore YY Control or signal Cable PVC / LSZH 300/300V  – AIPU

    High Reputation Lighting Cable - Multicore YY Control or signal Cable PVC / LSZH 300/300V – AIPU

    Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification:      Black Cores with White Number     1pc Green/Yellow Core 4. Sheath: PVC/LSZH (Grey) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Rated Voltage: 300/300V Reference Standards BS6500 BS EN 60228 BS EN 50525-2-11 BS EN 50363-3 BS EN 50363-7 BS EN 50363-4-1 BS EN 50363-8 RoHS Directives  IEC60332-1 0.5mm2 Part No. Conductor Construction (mm) Insulation ...
  • Fast Delivery Intercom Cable - Siemens PROFIBUS PA Cable 1x2x18AWG  – AIPU

    Fast Delivery Intercom Cable - Siemens PROFIBUS PA Cable 1x2x18AWG – AIPU

    Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1) 2. Insulation: S-PE 3. Identification: Red, Green 4. Filler: Halogen Free Compound 5. Screen:      ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Blue (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN...
  • Europe Style For Power And Control Cable - LiYcY Screened Multicore Control Cable  – AIPU

    Europe Style For Power And Control Cable - LiYcY Screened Multicore Control Cable – AIPU

    Constructions 1. Conductor: Class 5 Tinned Copper 2. Insulation: PVC 3. Identification: Colored 4. Cabling: Twisted Pair 5. Screen: Tinned Copper Wire Braided 6. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 0.14mm2 No. of Cores Conductor Construction (mm) Insulation Thickness (mm) Sheath Thickness (mm) Overall Diameter (mm) Max. DCR at 20℃ (Ω/km) LiYcY ...