About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Chinese Professional Silent Server Rack - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Super Lowest Price Computer Rack Cabinet - Outdoor Direct Buried Double Armored Fiber Optic Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA53 optical cable is a direct buried double armored fiber optic cable with double metal tape and two layers of PE sheath. It means this fiber optic cable has great side crush resistance performance and coordination. The plastic steel tape (PSP) longitudinal package effectively improves the moisture resistance of the optical cable. In that case this type of optical cable is more easily used in direct bu...
inquiry
detail
Cheapest Factory Cat7 Ethernet Cable - EIA RS-485 Cable 120ohm Communication & Industrial Cable – AIPU
Application 1. The cable is designed for RS-485 Cable data communication and automation systems, microprocessor to device, etc. Multi-pair cables are available, they could be widely used for production process control, computer automation systems, automatic process control and controller application. RS485 allows multiple drops and long cable lengths,high-speed, so it is also frequently used in industrial and automation fields. The RS-485 is also used in large-space theater venues, autom...
inquiry
detail
Oem/Odm Manufacturer Building Wire And Cable - Bosch CAN Bus Cable 1 Pair 120ohm shielded – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper. 2. Insulation: S-FPE. 3. Identification: 1 Pair: White, Brown. 1 Quad: White, Brown, Green, Yellow. 4. Wrapping Polyester Tape. 5. Screen: Tinned Copper Wire Braided. 6. Sheath: PVC/LSZH. 7. Sheath: Violet. Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Electrical Performance ...
inquiry
detail
Oem Customized Cable Data - LiHcH Screened Multicore Control Cable (LSZH) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 4. Screen: Tinned Copper Wire Braided 5. Sheath: LSZH Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1....
inquiry
detail
Hot Sale for Keystone Wall Plate Insert - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Good Quality Lszh Cat5e Cable - LiYcY TP Multipair Screened Control Cable – AIPU
Constructions 1. Conductor: Class 5 Tinned Copper 2. Insulation: PVC 3. Identification: Colored 4. Cabling: Twisted Pair 5. Screen: Tinned Copper Wire Braided 6. Sheath: PVC Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V ...
inquiry
detail
2021 Good Quality Data Cabling Your Home - Cat6A lan Cable, S/FTP 4 Pair Ethernet cable, Solid cable, 305M – AIPU
Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class D | UL Subject 444 Description Aipu-waton CAT6A S/FTP Cable supports the CAT6A channel requirements ANSI/TIA-568.2-D and ISO/IEC 11801 Class D. It supports the 10GBASE-T up to 100m in channel length which ensures that it can support the fastest Ethernet applications. The cable has an overall Shielded plus each pair is also shielded. This type cable is made by individual foil shielded 4 pair copper wire an outer braid which could impro...
inquiry
detail
Oem Manufacturer 4 Wire Data Cable - Single Core Non-sheathed Cable to EN50525-2-31 – AIPU
Constructions 1. Conductor: Class 1/2/5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification: Green/Yellow, Black, Blue, Brown, Red, White, Yellow, Grey, Violet, Grey, Orange, Pink Installation Temperature: Above 0ºC Operating Temperature: 70ºC, 90ºC Rated Voltage: 300/500V, 450/750V Test Voltage: 2000V, 2500V Reference Standards BS EN 50525-2-31 BS EN 60228 BS EN 50363 RoHS Directives IEC60332-1 Part No. Conductor Insulation Thickness (mm) Diameter (mm) Max. Res...
inquiry
detail
Wholesale Cat6a Data Cable - Security & Commercial Audio System (Unscreened) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-core cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Aipu offer a series of Security and Commercial Audio System for intercoms, security systems, audio systems, lighting, and temperature controls. We have 22AWG through 12AWG, shielded and unshielded, with PVC or LSZH jackets....
inquiry
detail
8 Year Exporter Computer Data Cable - Foundation Fieldbus Type B Cable – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-FPE 3. Identification: Blue, Orange 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH 7. Sheath: Orange Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Characteristic...
inquiry
detail
Factory Outlets Data Link Cable - Siemens PROFIBUS PA Cable 1x2x18AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1) 2. Insulation: S-PE 3. Identification: Red, Green 4. Filler: Halogen Free Compound 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Blue (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN...
inquiry
detail
<<
< Previous
167
168
169
170
171
172
173
Next >
>>
Page 170 / 340