About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Best-Selling Power Distribution Unit - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Quality Inspection for Utp Keystone Jack - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Factory Directly Multicore Control Cable - LiHH Multicore Control Cable (Halogen Free) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 5. Sheath: LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1.0~1.5mm2 300/500V 3000V 200 0.14...
inquiry
detail
China Cheap price Wall Mount Cabinet - Outdoor Direct Buried Double Armored Fiber Optic Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA53 optical cable is a direct buried double armored fiber optic cable with double metal tape and two layers of PE sheath. It means this fiber optic cable has great side crush resistance performance and coordination. The plastic steel tape (PSP) longitudinal package effectively improves the moisture resistance of the optical cable. In that case this type of optical cable is more easily used in direct bu...
inquiry
detail
100% Original Factory Server Rack Equipment - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
inquiry
detail
Quality Inspection For Speedy Data Cable - Siemens PROFIBUS PA Cable 1x2x18AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper (Class 1) 2. Insulation: S-PE 3. Identification: Red, Green 4. Filler: Halogen Free Compound 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Blue (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN...
inquiry
detail
Special Price For Multi Pair Telephone Cable - Audio cable Multi-core (Multi-Core, Unscreened) – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper or Tinned Copper 2. Insulation: Polyolefin 3. Cabling: Cores laying-up 4. Sheath: PVC/LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Identification of Insulation Operating Voltage 150V, 300V, 600V Test Voltage 1.0 KVdc Conductor DCR 57.0 Ω/km (Max. @ 20°C) for 22AWG 39.50 Ω/km (Max. @ 20°C) for 20AW...
inquiry
detail
China wholesale Fiber Optic Data Center - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
inquiry
detail
Big Discount 4 Pair Ethernet Cable - Foundation Fieldbus Type B Cable – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-FPE 3. Identification: Blue, Orange 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH 7. Sheath: Orange Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Characteristic...
inquiry
detail
Best Price For Data Bus Cable - Bosch CAN Bus Cable 1 Pair 120ohm shielded – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper. 2. Insulation: S-FPE. 3. Identification: 1 Pair: White, Brown. 1 Quad: White, Brown, Green, Yellow. 4. Wrapping Polyester Tape. 5. Screen: Tinned Copper Wire Braided. 6. Sheath: PVC/LSZH. 7. Sheath: Violet. Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Electrical Performance ...
inquiry
detail
Newly Arrival Serial Interface Cable - Foundation Fieldbus Type A Cable – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper 2. Insulation: S-FPE 3. Identification: Red, Green 4. Bedding: PVC 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS D...
inquiry
detail
Top Suppliers Cable Data Transfer - 318Y/B Cable 2-5 CORES PVC / LSZH 300/500V H05VV-F, H05Z1Z1-F – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC, LSZH 3. Identification: 2 Cores: Blue & Brown 3 Core: Green/Yellow, Blue & Brown 4 Core: Green/Yellow, Brown, Black & Grey 5 Core: Green/Yellow, Brown, Black Grey & Blue 4. Sheath: PVC, LSZH Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Bending Radius: 8 x overall diameter Rated Voltage: 300/500V Test Voltage: 2000V Reference Standards BS6500 BS EN...
inquiry
detail
<<
< Previous
222
223
224
225
226
227
228
Next >
>>
Page 225 / 340