About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Discount Price H05vv Cable - Foundation Fieldbus Type A Cable – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper 2. Insulation: S-FPE 3. Identification: Red, Green 4. Bedding: PVC 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS D...
inquiry
detail
Reliable Supplier Foil Shielded Cable - Computer, Instrumentation and Medical Electronics Cable – AIPU
Application 1. The cable is designed for BMS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-core cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. PVC or LSZH sheath are both available. 3. Medical Electronics Cable for communication Cable RS-232,RS422,RS485 and so on. Due to the need for high flexibility of flexible cable in the process of use. They are mainly used t...
inquiry
detail
Chinese wholesale Silent Rack Server - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Trending Products Network Rack Patch Panel - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
8 Year Exporter Good Instrument Cables - Audio cable Multi-core (Multi-Core, Unscreened) – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper or Tinned Copper 2. Insulation: Polyolefin 3. Cabling: Cores laying-up 4. Sheath: PVC/LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Identification of Insulation Operating Voltage 150V, 300V, 600V Test Voltage 1.0 KVdc Conductor DCR 57.0 Ω/km (Max. @ 20°C) for 22AWG 39.50 Ω/km (Max. @ 20°C) for 20AW...
inquiry
detail
China Supplier Push Pull Cable Lever - Audio, Control and Instrumentation Cables (Multi-Core, Screened) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-corer cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire,Tinned Copper Braided and Spiral are optional. 3. PVC or LSZH sheath are both available. 4. Aipu has employees about 2000people and among them 200 people are...
inquiry
detail
Chinese Wholesale Pvc Data Cable - Foundation Fieldbus Type A Cable – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper 2. Insulation: S-FPE 3. Identification: Red, Green 4. Bedding: PVC 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS D...
inquiry
detail
Manufacturer Of Instrument Audio Cable - ControlBus Cable 1 Pair for System Bus – AIPU
Constructions 1. Conductor: Oxygen Free Copper or Tinned Copper Wire 2. Insulation: S-PE, S-FPE 3. Identification: Color Coded 4. Cabling: Twisted Pair 5. Screen: ● Aluminium/Polyester Tape ● Tinned Copper Wire Braided 6. Sheath: PVC/LSZH (Note: Armor by Gavanized Steel Wire or Steel Tape is under request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Refere...
inquiry
detail
Renewable Design For Hard Disk Data Cable - Security & Commercial Audio System (Screened) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-pair cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Al-PET tape with Tinned Copper Drain Wire shielded are optional. 3. PVC or LSZH sheath are both available. 4. The difference between a commercial audio system and a home music system is that in a commercial audio system, yo...
inquiry
detail
High Performance Shielded Data Cable - Schneider (Modicon) MODBUS Cable 3x2x22AWG – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-PE, S-PP 3. Identification: Color Coded 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Electrical Performance Working Voltage 300V Test Voltage 1.0KV Velocity of Propagatio...
inquiry
detail
2021 Latest Design Punch Down Keystone Jack - Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
Reasonable Price For Data Center Cable - CY Screened Multicore Control Cable – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification: Black Cores with White Number 1pc Green/Yellow Core 4. Screen: Tinned Copper Wire Braided 5. Sheath: PVC/LSZH (Grey) Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Rated Voltage: 300/300V Reference Standards BS6500 BS EN 60228 BS EN 50525-2-11 BS EN 50363-3 BS EN 50363-7 BS EN 50363-4-1 BS EN 50363-8 RoHS Directives IEC60332-1 0.5mm2 Part No. Conduc...
inquiry
detail
<<
< Previous
231
232
233
234
235
236
237
Next >
>>
Page 234 / 340