About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
2021 Latest Design Delta Communication Cable - Echelon LonWorks Cable 1x2x22AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper 2. Insulation: S-PE, S-FPE 3. Identification: ● Pair 1: White, Blue ● Pair 2: White, Orange 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: LSZH 7. Sheath: White (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Reference Standards EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC...
inquiry
detail
Factory wholesale Copper Cat5e Cable - Cat6 U/UTP 4 Pair outdoor Lan cable, Solid cable – AIPU
Standards ANSI/TIA-568.2-D | ISO/IEC 11801 Class D | UL Subject 444 Description Aipu-waton CAT6 outdoor U/UTP outdoor lan Cable is an ideal product for outdoor network installation environment, but also provide 250MHz bandwidth in 100m and speed rate 1000Mbps which means it is far exceed Cat5e outdoor cable parameters. Same as the U/UTP cat6 indoor cable, its nominal conductor diameter is 0.55mm with a cross filler between each pair of the conductors. Each conductor is made of annea...
inquiry
detail
Manufacturer for Short Rack Server - Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
Fast delivery Voice And Data Cabling - Cat.6A Network Unshielded 24-Port Patch Panel – AIPU
Product Quality Product quality is essential to a reliable network. AIPU’s CAT6A patch panel meets TIA/EIA 568A & 568B standards. The RJ45 ports mount flush against the panel’s face which helps eliminate cable snags and create a professional aesthetic. This CAT6A Patch Panel is not only ideal for speed and efficiency but also great for cable organization. Durability & Strength To ensure our CAT6 Patch Panel’s durability and strength, we use SPCC 16 gauge st...
inquiry
detail
Factory source Full Height Server Rack - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Outdoor Direct Buried Double Armored Fiber Optic Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA53 optical cable is a direct buried double armored fiber optic cable with double metal tape and two layers of PE sheath. It means this fiber optic cable has great side crush resistance performance and coordination. The plastic steel tape (PSP) longitudinal package effectively improves the moisture resistance of the optical cable. In that case this type of optical cable is more easily used in direct bu...
inquiry
detail
High Quality for Computer Server Cabinet - Outdoor Direct Buried Double Armored Fiber Optic Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA53 optical cable is a direct buried double armored fiber optic cable with double metal tape and two layers of PE sheath. It means this fiber optic cable has great side crush resistance performance and coordination. The plastic steel tape (PSP) longitudinal package effectively improves the moisture resistance of the optical cable. In that case this type of optical cable is more easily used in direct bu...
inquiry
detail
Oem China Blue Data Cable - Multicore Speaker Cable For Commercial Infrastructure – AIPU
Application 1. The cable is designed for loudspeaker application. It could be used for car audio, home HiFi, cinema, or speaker system with high-end cables for an unforgettable sound experience. 2. The three key electrical characteristics of a speaker cable are resistance, capacitance, and inductance. Of these, resistance is the most important. The speaker cable is the wire that connects the speaker to the amplifier source. 3. The resistance of loudspeaker is mainly affected by conduct...
inquiry
detail
Factory Cheap Server Rack Power - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Hot Selling For Delta Plc Communication Cable - Echelon LonWorks Cable 1x2x22AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper 2. Insulation: S-PE, S-FPE 3. Identification: ● Pair 1: White, Blue ● Pair 2: White, Orange 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: LSZH 7. Sheath: White (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Reference Standards EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC...
inquiry
detail
Factory Selling Nurse Call Cable - Echelon LonWorks Cable 1x2x22AWG – AIPU
Constructions 1. Conductor: Solid Oxygen Free Copper 2. Insulation: S-PE, S-FPE 3. Identification: ● Pair 1: White, Blue ● Pair 2: White, Orange 4. Cabling: Twisted Pair 5. Screen: Aluminum/Polyester Tape 6. Sheath: LSZH 7. Sheath: White (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Reference Standards EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC...
inquiry
detail
Fixed Competitive Price Metal Data Cable - DeviceNet Cable Combo Type by Rockwell Automation (Allen-Bradley) – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: PVC, S-PE, S-FPE 3. Identification: ● Data: White, Blue ● Power: Red, Black 4. Cabling: Twisted Pair Laying-up 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet/Grey/Yellow Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending ...
inquiry
detail
<<
< Previous
246
247
248
249
250
251
252
Next >
>>
Page 249 / 340