About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
Good Quality Solid Cat5e Cable - Audio, Control and Instrumentation Cables (Special) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-pair cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire shielded are optional. 3. PVC or LSZH sheath are both available. 4. The special instrumentation cables consists of 1pair of power cable to transmission the po...
inquiry
detail
Quality Inspection For Fire Alarm Cable - LiYY Multicore Flexible Data, Signal & Control Cable (PVC) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC 3. Identification: Colored 4. Sheath: PVC Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1.0~1.5mm2 300/500V 3000V 200 0.14mm2 ...
inquiry
detail
2021 Good Quality Outdoor Lan Cable - KNX/EIB Building Automation Cable by EIB & EHS – AIPU
Constructions Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN 50090 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Cable Construction Part No. APYE00819 for PVC APYE00820 for PVC APYE00905 for LSZH APYE00906 for LSZH Structure 1x2x20AWG 2x2x20AWG Conductor Material Solid Oxygen Free Copper Conductor Size 0.80mm Insulation S-PE Id...
inquiry
detail
factory customized Server Rack Mounting Rails - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
inquiry
detail
2021 High quality Server Room Rack - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
inquiry
detail
Factory Price For Data Extension Cable - Multipair RS-422 Cable 24AWG Communication Cable – AIPU
Application 1. The cable is designed for for EIA RS 422 applications, used as computer cables. Multi-pair cables are available. It could be widely used for production process control and Device Converter. 2. The RS-422 (TIA/EIA-422) has higher speed, better noise resistance and longer cable length than the older RS-232C standard. 3. The RS-422 system can transmit data at rates up to 10 Mbit/s and can transmit data up to 1,200 meters (3,900 feet). The RS-422 was widely used in early Maci...
inquiry
detail
Newly Arrival Armored Instrumentation Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU
Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 4. Screen: Tinned Copper Wire Braided 5. Sheath: LSZH Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1....
inquiry
detail
High Quality Lszh Cat6 Cable - Multipair RS-422 Cable 24AWG Communication Cable – AIPU
Application 1. The cable is designed for for EIA RS 422 applications, used as computer cables. Multi-pair cables are available. It could be widely used for production process control and Device Converter. 2. The RS-422 (TIA/EIA-422) has higher speed, better noise resistance and longer cable length than the older RS-232C standard. 3. The RS-422 system can transmit data at rates up to 10 Mbit/s and can transmit data up to 1,200 meters (3,900 feet). The RS-422 was widely used in early Maci...
inquiry
detail
Low price for Structured Cabling - Cat.6A Network Unshielded 24-Port Patch Panel – AIPU
Product Quality Product quality is essential to a reliable network. AIPU’s CAT6A patch panel meets TIA/EIA 568A & 568B standards. The RJ45 ports mount flush against the panel’s face which helps eliminate cable snags and create a professional aesthetic. This CAT6A Patch Panel is not only ideal for speed and efficiency but also great for cable organization. Durability & Strength To ensure our CAT6 Patch Panel’s durability and strength, we use SPCC 16 gauge st...
inquiry
detail
Chinese wholesale Patch Panel - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
inquiry
detail
18 Years Factory Purple And Gray Dimming Cable - Audio cable Multi-core (Multi-Core, Unscreened) – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper or Tinned Copper 2. Insulation: Polyolefin 3. Cabling: Cores laying-up 4. Sheath: PVC/LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Identification of Insulation Operating Voltage 150V, 300V, 600V Test Voltage 1.0 KVdc Conductor DCR 57.0 Ω/km (Max. @ 20°C) for 22AWG 39.50 Ω/km (Max. @ 20°C) for 20AW...
inquiry
detail
High Definition Cable Keystone Jack - Single Core Non-sheathed Cable to EN50525-2-31 – AIPU
Constructions 1. Conductor: Class 1/2/5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification: Green/Yellow, Black, Blue, Brown, Red, White, Yellow, Grey, Violet, Grey, Orange, Pink Installation Temperature: Above 0ºC Operating Temperature: 70ºC, 90ºC Rated Voltage: 300/500V, 450/750V Test Voltage: 2000V, 2500V Reference Standards BS EN 50525-2-31 BS EN 60228 BS EN 50363 RoHS Directives IEC60332-1 Part No. Conductor Insulation Thickness (mm) Diameter (mm) Max. Res...
inquiry
detail
<<
< Previous
319
320
321
322
323
324
325
Next >
>>
Page 322 / 340