Featured

  • High Quality Cat5e Cable - Foundation Fieldbus Type A Cable 18~14AWG  – AIPU

    High Quality Cat5e Cable - Foundation Fieldbus Type A Cable 18~14AWG – AIPU

    Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: Polyolefin 3. Identification: Blue, Orange 4. Screen: Individual & Overall Screen 5. Sheath: PVC/LSZH 6. Sheath: Yellow Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Cond...
  • Super Lowest Price Profibus Cable - Foundation Fieldbus Type A Cable  – AIPU

    Super Lowest Price Profibus Cable - Foundation Fieldbus Type A Cable – AIPU

    Constructions 1. Conductor: Stranded Oxygen Free Copper 2. Insulation: S-FPE 3. Identification: Red, Green 4. Bedding: PVC 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.)  Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS D...
  • OEM Factory for Enclosure Server - Outdoor central loose tube Fiber Optic Cable-GYXTW  – AIPU

    OEM Factory for Enclosure Server - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
  • Special Design for Network Switch Cabinet - Indoor Tight Buffered Fiber Optic Cable-GJFJV  – AIPU

    Special Design for Network Switch Cabinet - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
  • 8 Year Exporter Keystone Data Jacks - Outdoor FTTH Self-supporting Bow-Type drop Cable  – AIPU

    8 Year Exporter Keystone Data Jacks - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
  • Massive Selection for Rj45 Patch Panel - Indoor Tight Buffered Fiber Optic Cable-GJFJV  – AIPU

    Massive Selection for Rj45 Patch Panel - Indoor Tight Buffered Fiber Optic Cable-GJFJV – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton indoor tight buffered optical cable uses 900μm buffered fibers. Tight buffer fiber optic cable designs are typically smaller in size and more flexible. It doesn’t provide protection from water migration and doesn’t isolate fibers well from the expansion and contraction of other materials due to temperature extremes. Tight buffered fiber cable, often called premise or distribution cables, are i...
  • Factory made hot-sale Server Rack Cooling System - Outdoor FTTH Self-supporting Bow-Type drop Cable  – AIPU

    Factory made hot-sale Server Rack Cooling System - Outdoor FTTH Self-supporting Bow-Type drop Cable – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GJYXCH and GJYXFCH optical cable is an outdoor FTTH bow-type drop cable. The optical cable contains 1 ~ 4 silica optical fibers with coating, which can be G657A1 or G652D. The optical fibers manufactured by the same design, material and process shall be used in the same batch of products, and the optical fibers shall be placed in the center of the optical cable. The optical fiber coating layer can be colo...
  • 100% Original Microphone Cable - RS-232 Cable (Multi-Pair, Foil Screened)  – AIPU

    100% Original Microphone Cable - RS-232 Cable (Multi-Pair, Foil Screened) – AIPU

    Application 1. The cable is designed for RS-232 Cable low data rate transmission as audio, control and instrumentation cables, etc. Multi-core or multi twist pair laying up cables are available. It could be widely used for computer serial ports, industrial communication equipment. PLC use it connect modems, and also to printers, computer mice, data storage, uninterrupted power supplies, and other peripherals. In twisted pair cabling, two conductors of a single circuit are twisted togethe...
  • Factory Directly Supply Cat6a Network Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU

    Factory Directly Supply Cat6a Network Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU

    Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PE 3. Identification: Colored 4. Screen: Tinned Copper Wire Braided 5. Sheath: LSZH Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Reference Standards VDE 0812 DIN 1704 VDE 0207 RoHS Directives IEC60332-1 IEC60754 Section Area Rated Voltage Test Voltage Min. Insulation Resistance at 20℃ (MΩ/km) 0.14~0.34mm2 250/250V 1.2kV 200 0.5~0.75mm2 300V 2000V 200 1....
  • Cheap price Data Center Server Rack - Stranded loose tube direct buried or aerial optical Cable  – AIPU

    Cheap price Data Center Server Rack - Stranded loose tube direct buried or aerial optical Cable – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
  • 2021 High quality Open Rack - Outdoor Direct Buried Double Armored Fiber Optic Cable  – AIPU

    2021 High quality Open Rack - Outdoor Direct Buried Double Armored Fiber Optic Cable – AIPU

    Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA53 optical cable is a direct buried double armored fiber optic cable with double metal tape and two layers of PE sheath. It means this fiber optic cable has great side crush resistance performance and coordination. The plastic steel tape (PSP) longitudinal package effectively improves the moisture resistance of the optical cable. In that case this type of optical cable is more easily used in direct bu...
  • Factory Wholesale Solid Ethernet Cable - CY Screened Multicore Control Cable  – AIPU

    Factory Wholesale Solid Ethernet Cable - CY Screened Multicore Control Cable – AIPU

    Constructions 1. Conductor: Class 5 Oxygen Free Copper 2. Insulation: PVC/LSZH 3. Identification:      Black Cores with White Number      1pc Green/Yellow Core 4. Screen: Tinned Copper Wire Braided 5. Sheath: PVC/LSZH (Grey) Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Rated Voltage: 300/300V Reference Standards BS6500 BS EN 60228 BS EN 50525-2-11 BS EN 50363-3 BS EN 50363-7 BS EN 50363-4-1 BS EN 50363-8 RoHS Directives IEC60332-1 0.5mm2 Part No. Conduc...