About Us
Brief Introduction
Group Member
Production Base
Products
Wire&Cable
Instrumentation Cable
Belden Equivalent Cable
RS-485 Cable
RS-232 Cable (Multi-core)
RS-232 Cable (Multi-pair)
RS-232/422 Cable
Audio Cable (Analog)
Audio Cable (Digital)
Speaker Cable
Security & Commercial Audio System (Unscreened)
Security & Commercial Audio System (Screened)
Computer, Instrumentation & Medical Electronics Cable
Audio, Control and Instrumentation Cable (Multi-core, Screened)
Audio, Control and Instrumentation Cable (Multi-pair, Unscreened)
Audio, Control and Instrumentation Cable (Multi-pair, Screened)
Industrial Control Cable
YY Cable
CY Cable
LiYY Cable
LiYY TP Cable
LiHH Cable
LiYcY Cable
LiHcH Cable
LiYcY TP Cable
309Y (H05V2V2-F) Cable
218Y/B (H03VV-F) Cable, 219Y/B (H03VVH2-F) Cable
318Y/B (H05VV-F) Cable, 319Y/B (H05VVH2-F) Cable
Non-sheathed Cable to EN50525-2-31
Fieldbus Cable
KNX/EIB Cable
CAN BUS Cable
PROFIBUS PA Cable
PROFIBUS DP Cable
PROFINET Cable Type A
DeviceNet Cable
LonWorks Cable
ControlBus Cable
MODBUS Cable
Foundation Fieldbus Type A Cable
Foundation Fieldbus Type B Cable
Copper Cabling Solution
keystone jacks
Lan Cable
Patch Panel
Patch Cable
Fiber Optic Solution
Optical Cable
Services
Catalogue
Certificates
System Warranty
Become A Partner
News
Contact
English
Home
Featured
Featured
High Reputation Lighting Cable - Foundation Fieldbus Type A Cable – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper 2. Insulation: S-FPE 3. Identification: Red, Green 4. Bedding: PVC 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet (Note: Armor by Galvanized Steel Wire or Steel Tape is upon request.) Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS D...
inquiry
detail
One Of Hottest For Multi Core Electrical Cable - Foundation Fieldbus Type A Cable 18~14AWG – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: Polyolefin 3. Identification: Blue, Orange 4. Screen: Individual & Overall Screen 5. Sheath: PVC/LSZH 6. Sheath: Yellow Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Cond...
inquiry
detail
Good Quality Cabling Server Rack - Cat.5e Unshielded RJ45 24AWG Patch Cord(5m) – AIPU
Standards Fully Conforms to ANSI/TIA-568-C Product Parameters
inquiry
detail
Discount Price 23awg Ethernet Cable - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU
Application 1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-pair cables are available. It could be widely used for production process control and Device Converter audio instrument. 2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire shielded are optional. 3. PVC or LSZH sheath are both available. 4. Instrumentation cable is a multi-conductor cable, generally single or multiple pairs, used...
inquiry
detail
Manufactur Standard Electric Drum Cables - Indoor Network Cable Lan Cable Audio Cable Multi-core Multi-Core Unscreened PVC Sheath LSZH for Production Process Control Device Converter Audio Instrument – AIPU
Constructions 1. Conductor: Stranded Oxygen Free Copper or Tinned Copper 2. Insulation: Polyolefin 3. Cabling: Cores laying-up 4. Sheath: PVC/LSZH Installation Temperature: Above 0℃ Operating Temperature: -15℃ ~ 70℃ Reference Standards BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Identification of Insulation Operating Voltage 150V, 300V, 600V Test Voltage 1.0 KVdc Conductor DCR 57.0 Ω/km (Max. @ 20°C) for 22AWG 39.50 Ω/km (Max. @ 20°C) for 20AW...
inquiry
detail
China New Product Armoured Control Cable - Computer Bulk Cable Coaxial Cable RS232 Cable LAN Cable MultiCore Foil Braid Screened with Tinned Copper Dain Wire – AIPU
Application 1. The cable is designed for RS-232 Cable low data rate transmission as audio, control and instrumentation cables, etc. Multi-core or multi twist pair laying up cables are available.RS232 is a kind of communication mode and called serial connection in telecommunications. It could be widely used for computer serial ports, industrial communication equipment, PLC use it connect modems, and also to printers, computer mice, data storage, uninterrupted power supplies, and other per...
inquiry
detail
Hot Sale for Keystone Wall Plate Insert - Stranded loose tube direct buried or aerial optical Cable – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTS optical cable is a direct buried or aerial used outdoor fiber optic cable which takes the same structure as GYTA optical cable. There are also multi tubes filled by waterproof compound with inside fiber cores. There is a steel strength member in the middle of the cable for The center of the optical cable is a steel wire strength member which is covered by PE material occasionally. All the loose tubes...
inquiry
detail
High Quality Fiber Optic Data Cable - Outdoor central loose tube Fiber Optic Cable-GYXTW – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton central loose tube optical cables provides up to 24 fibers in a robust all dielectric design which the central loose tube is the economical option for fiber counts no more than 24 fibers. It offers a smaller overall dimension and ensures a more efficient use of conduit space than stranded loose tube. The central tube minimizes the amount of labor and material required to install the cable. The number of b...
inquiry
detail
Oem Customized Cable Data - Computer Bulk Cable Coaxial Cable RS232 Cable LAN Cable MultiCore Foil Braid Screened with Tinned Copper Dain Wire – AIPU
Application 1. The cable is designed for RS-232 Cable low data rate transmission as audio, control and instrumentation cables, etc. Multi-core or multi twist pair laying up cables are available.RS232 is a kind of communication mode and called serial connection in telecommunications. It could be widely used for computer serial ports, industrial communication equipment, PLC use it connect modems, and also to printers, computer mice, data storage, uninterrupted power supplies, and other per...
inquiry
detail
Hot New Products Pvc Cat5e Cable - DeviceNet Cable Combo Type by Rockwell Automation (Allen-Bradley) – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: PVC, S-PE, S-FPE 3. Identification: ● Data: White, Blue ● Power: Red, Black 4. Cabling: Twisted Pair Laying-up 5. Screen: ● Aluminum/Polyester Tape ● Tinned Copper Wire Braided (60%) 6. Sheath: PVC/LSZH 7. Sheath: Violet/Grey/Yellow Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending ...
inquiry
detail
Manufacturing Companies For Heat Trace Cable - Foundation Fieldbus Type B Cable – AIPU
Constructions 1. Conductor: Stranded Tinned Copper Wire 2. Insulation: S-FPE 3. Identification: Blue, Orange 5. Screen: Aluminum/Polyester Tape 6. Sheath: PVC/LSZH 7. Sheath: Orange Installation Temperature: Above 0ºC Operating Temperature: -15ºC ~ 70ºC Minimum Bending Radius: 8 x overall diameter Reference Standards BS EN/IEC 61158 BS EN 60228 BS EN 50290 RoHS Directives IEC60332-1 Electrical Performance Working Voltage 300V Test Voltage 1.5KV Characteristic...
inquiry
detail
OEM/ODM Factory Cat 6 Data Outlet - Stranded loose tube non-metallic Fiber Optic Cable-GYTA Standards – AIPU
Standards In accordance with IEC, ITU and EIA standards Description Aipu-waton GYTA optical cable is a duct or aerial used outdoor fiber optic cable which consists of single mode or multi mode fibers in several loose tubes. Those loose tubes are fulfilled with waterproof compound. The center of the optical cable is a steel wire strength member which is covered by PE material for some of the GYTA cable. All the loose tubes are twisted around the central strength member into a round f...
inquiry
detail
<<
< Previous
82
83
84
85
86
87
88
Next >
>>
Page 85 / 340