With state-of-the-art technologies and facilities, strict good quality regulate, reasonable cost, exceptional assistance and close co-operation with prospects, we're devoted to supplying the top benefit for our customers for Rack Enclosure Cabinet, Data Line Cable, Communication Cable, Welcome to make contact with us if you're fascinated inside our product, we are going to provide you with a surprice for Qulity and Value.
High Quality For Cable Manager - LiYcY TP Multipair Screened Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR at
20℃ (Ω/km)

LiYcY TP 1x2x0.14

12/0.12

0.35

0.7

4.4

148

LiYcY TP 2x2x0.14

12/0.12

0.35

0.7

6.1

148

LiYcY TP 3x2x0.14

12/0.12

0.35

0.8

6.7

148

LiYcY TP 4x2x0.14

12/0.12

0.35

0.8

7.2

148

LiYcY TP 6x2x0.14

12/0.12

0.35

0.8

8.3

148

LiYcY TP 8x2x0.14

12/0.12

0.35

0.8

9.4

148

LiYcY TP 10x2x0.14

12/0.12

0.35

0.9

10.8

148

LiYcY TP 12x2x0.14

12/0.12

0.35

1.0

11.4

148

0.25mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.25

14/0.15

0.4

0.7

4.8

79.9

LiYcY TP 2x2x0.25

14/0.15

0.4

0.8

7

79.9

LiYcY TP 3x2x0.25

14/0.15

0.4

0.8

7.4

79.9

LiYcY TP 4x2x0.25

14/0.15

0.4

0.8

8

79.9

LiYcY TP 6x2x0.25

14/0.15

0.4

0.8

9.6

79.9

LiYcY TP 8x2x0.25

14/0.15

0.4

0.9

10.8

79.9

LiYcY TP 10x2x0.25

14/0.15

0.4

1.0

12.3

79.9

LiYcY TP 12x2x0.25

14/0.15

0.4

1.1

12.6

79.9

0.34mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.34

20/0.15

0.4

0.7

5.2

57

LiYcY TP 2x2x0.34

20/0.15

0.4

0.8

7.7

57

LiYcY TP 3x2x0.34

20/0.15

0.4

0.8

8.2

57

LiYcY TP 4x2x0.34

20/0.15

0.4

0.8

9

57

LiYcY TP 6x2x0.34

20/0.15

0.4

0.9

10.8

57

LiYcY TP 8x2x0.34

20/0.15

0.4

1.0

12.2

57

LiYcY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYcY TP 12x2x0.34

20/0.15

0.4

1.2

14.7

57

0.50mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.5

16/0.20

0.45

0.7

5.6

39

LiYcY TP 2x2x0.5

16/0.20

0.45

0.8

8.3

39

LiYcY TP 3x2x0.5

16/0.20

0.45

0.8

9.1

39

LiYcY TP 4x2x0.5

16/0.20

0.45

0.9

10

39

LiYcY TP 6x2x0.5

16/0.20

0.45

1.0

12

39

LiYcY TP 8x2x0.5

16/0.20

0.45

1.1

13.1

39

LiYcY TP 10x2x0.5

16/0.20

0.45

1.2

15.5

39

0.75mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.75

24/0.20

0.5

0.8

6.4

26

LiYcY TP 2x2x0.75

24/0.20

0.5

0.8

9.6

26

LiYcY TP 3x2x0.75

24/0.20

0.5

0.9

10.5

26

LiYcY TP 4x2x0.75

24/0.20

0.5

1.0

11.4

26

LiYcY TP 6x2x0.75

24/0.20

0.5

1.1

13.7

26

LiYcY TP 8x2x0.75

24/0.20

0.5

1.2

15

26

LiYcY TP 10x2x0.75

24/0.20

0.5

1.3

17.7

26

1.0mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.0

32/0.20

0.6

0.8

7.2

19.5

LiYcY TP 2x2x1.0

32/0.20

0.6

0.9

11.1

19.5

LiYcY TP 3x2x1.0

32/0.20

0.6

1.0

12.2

19.5

LiYcY TP 4x2x1.0

32/0.20

0.6

1.0

13.1

19.5

LiYcY TP 6x2x1.0

32/0.20

0.6

1.2

15

19.5

LiYcY TP 8x2x1.0

32/0.20

0.6

1.3

17.4

19.5

1.5mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.5

30/0.25

0.6

0.8

7.8

13.3

LiYcY TP 2x2x1.5

30/0.25

0.6

1.0

12.3

13.3

LiYcY TP 3x2x1.5

30/0.25

0.6

1.1

13.5

13.3

LiYcY TP 4x2x1.5

30/0.25

0.6

1.2

14.7

13.3


Product detail pictures:

High Quality For Cable Manager - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures

High Quality For Cable Manager - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures


Related Product Guide:

We continue to keep increasing and perfecting our solutions and service. At the same time, we operate actively to do research and enhancement for High Quality For Cable Manager - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: moldova, Islamabad, Leicester, We've been always creating new technology to streamline the production, and give products with competitive prices and high quality! Customer satisfaction is our priority! You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We are going to present our best service to satisfy all your needs! Remember to contact us right away!
  • The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Bess from India - 2018.09.21 11:01
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Miguel from Moldova - 2017.06.29 18:55
    Write your message here and send it to us