Hot Sale For Data Cable Management - CY Screened Multicore Control Cable – AIPU
Hot Sale For Data Cable Management - CY Screened Multicore Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC/LSZH
3. Identification:
Black Cores with White Number
1pc Green/Yellow Core
4. Screen: Tinned Copper Wire Braided
5. Sheath: PVC/LSZH (Grey)
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Rated Voltage: 300/300V
Reference Standards
BS6500
BS EN 60228
BS EN 50525-2-11
BS EN 50363-3
BS EN 50363-7
BS EN 50363-4-1
BS EN 50363-8
RoHS Directives
IEC60332-1
0.5mm2
Part No. |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 2×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.6 |
39 |
CY 3×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
5.9 |
39 |
CY 4×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
39 |
CY 5×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
39 |
CY 7×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
39 |
CY 8×0.5 |
16/0.20 |
0.4 |
0.8 |
TC Braided |
8 |
39 |
CY 10×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
0.6 |
39 |
CY 12×0.5 |
16/0.20 |
0.4 |
1 |
TC Braided |
9.9 |
39 |
CY 16×0.5 |
16/0.20 |
0.4 |
1.1 |
TC Braided |
11 |
39 |
0.75mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 2×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6 |
26 |
CY 3×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.3 |
26 |
CY 4×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
26 |
CY 5×0.75 |
24/0.20 |
0.4 |
0.8 |
TC Braided |
7.33 |
26 |
CY 7×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
26 |
CY 8×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
26 |
CY 10×0.75 |
24/0.20 |
0.4 |
0.9 |
TC Braided |
10.2 |
26 |
CY 12×0.75 |
24/0.20 |
0.4 |
1 |
TC Braided |
10.8 |
26 |
CY 16×0.75 |
24/0.20 |
0.4 |
1.1 |
TC Braided |
12 |
26 |
1.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 2×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.4 |
19.5 |
CY 3×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
6.8 |
19.5 |
CY 4×1.0 |
32/0.20 |
0.4 |
0.8 |
TC Braided |
7.3 |
19.5 |
CY 5×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.1 |
19.5 |
CY 7×1.0 |
32/0.20 |
0.4 |
0.9 |
TC Braided |
8.9 |
19.5 |
CY 8×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
9.8 |
19.5 |
CY 10×1.0 |
32/0.20 |
0.4 |
1 |
TC Braided |
11.2 |
19.5 |
CY 12×1.0 |
32/0.20 |
0.4 |
1.1 |
TC Braided |
11.7 |
19.5 |
CY 16×1.0 |
32/0.20 |
0.4 |
1.2 |
TC Braided |
13.1 |
19.5 |
1.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 2×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7 |
13.3 |
CY 3×1.5 |
30/0.25 |
0.4 |
0.8 |
TC Braided |
7.4 |
13.3 |
CY 4×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
8.2 |
13.3 |
CY 5×1.5 |
30/0.25 |
0.4 |
0.9 |
TC Braided |
9.1 |
13.3 |
CY 7×1.5 |
30/0.25 |
0.4 |
1 |
TC Braided |
10 |
13.3 |
CY 8×1.5 |
30/0.25 |
0.4 |
1.1 |
TC Braided |
11 |
13.3 |
CY 10×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
12.8 |
13.3 |
CY 12×1.5 |
30/0.25 |
0.4 |
1.2 |
TC Braided |
13.2 |
13.3 |
CY 16×1.5 |
30/0.25 |
0.4 |
1.3 |
TC Braided |
14.7 |
13.3 |
2.5mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 2×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
8.2 |
7.98 |
CY 3×2.5 |
48/0.25 |
0.5 |
0.9 |
TC Braided |
9.1 |
7.98 |
CY 4×2.5 |
48/0.25 |
0.5 |
1 |
TC Braided |
10.1 |
7.98 |
CY 5×2.5 |
48/0.25 |
0.5 |
1.1 |
TC Braided |
11.1 |
7.98 |
CY 7×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.2 |
7.98 |
CY 8×2.5 |
48/0.25 |
0.5 |
1.2 |
TC Braided |
12.8 |
7.98 |
CY 10×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15 |
7.98 |
CY 12×2.5 |
48/0.25 |
0.5 |
1.3 |
TC Braided |
15.6 |
7.98 |
CY 16×2.5 |
48/0.25 |
0.5 |
1.4 |
TC Braided |
17.3 |
7.98 |
4.0mm2
No. of Cores |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Screen (mm) |
Overall |
Max. DCR (Ω/km) |
CY 3×4.0 |
56/0.30 |
0.6 |
1.1 |
TC Braided |
11.4 |
4.95 |
CY 4×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
12.4 |
4.95 |
CY 5×4.0 |
56/0.30 |
0.6 |
1.2 |
TC Braided |
13.5 |
4.95 |
CY 7×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
14.8 |
4.95 |
CY 8×4.0 |
56/0.30 |
0.6 |
1.3 |
TC Braided |
16.0 |
4.95 |
Product detail pictures:
Related Product Guide:
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of employees building, striving hard to boost the standard and liability consciousness of staff members. Our corporation successfully attained IS9001 Certification and European CE Certification of Hot Sale For Data Cable Management - CY Screened Multicore Control Cable – AIPU , The product will supply to all over the world, such as: Leicester, Jakarta, Italy, For many years, we now have adhered to the principle of customer oriented, quality based, excellence pursuing, mutual benefit sharing. We hope, with great sincerity and good will, to have the honor to help with your further market.
By Colin Hazel from French - 2017.06.29 18:55
In general, we are satisfied with all aspects, cheap, high-quality, fast delivery and good procuct style, we will have follow-up cooperation!
By Madge from Israel - 2017.10.13 10:47