Hot-Selling Building Wire - LiYY TP Multipair Control Cable – AIPU
Hot-Selling Building Wire - LiYY TP Multipair Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.3 |
148 |
LiYY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.7 |
148 |
LiYY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.4 |
148 |
LiYY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.7 |
7.5 |
148 |
LiYY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.6 |
148 |
LiYY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10 |
148 |
LiYY TP 12x2x0.14 |
12/0.12 |
0.35 |
1 |
10.4 |
148 |
LiYY TP 15x2x0.14 |
12/0.12 |
0.35 |
1.1 |
11.6 |
148 |
0.25mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6 |
79.9 |
LiYY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6.4 |
79.9 |
LiYY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.7 |
7.2 |
79.9 |
LiYY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8.8 |
79.9 |
LiYY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.8 |
79.9 |
LiYY TP 10x2x0.25 |
14/0.15 |
0.4 |
1 |
11.5 |
79.9 |
LiYY TP 12x2x0.25 |
14/0.15 |
0.4 |
1 |
12.1 |
79.9 |
LiYY TP 15x2x0.25 |
14/0.15 |
0.4 |
1.1 |
13.5 |
79.9 |
0.34mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.6 |
6.7 |
57 |
LiYY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.6 |
7.2 |
57 |
LiYY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.7 |
8 |
57 |
LiYY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10 |
57 |
LiYY TP 8x2x0.34 |
20/0.15 |
0.4 |
1 |
11.4 |
57 |
LiYY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
LiYY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.4 |
57 |
LiYY TP 15x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.9 |
57 |
0.50mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.7 |
7.5 |
39 |
LiYY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.7 |
8.1 |
39 |
LiYY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9 |
39 |
LiYY TP 6x2x0.5 |
16/0.20 |
0.45 |
1 |
11.2 |
39 |
LiYY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
12.8 |
39 |
LiYY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
14.7 |
39 |
LiYY TP 12x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15 |
39 |
LiYY TP 15x2x0.5 |
16/0.20 |
0.45 |
1.3 |
16.7 |
39 |
0.75mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.7 |
8.6 |
26 |
LiYY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.5 |
26 |
LiYY TP 4x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.4 |
26 |
LiYY TP 6x2x0.75 |
24/0.20 |
0.5 |
1 |
12.7 |
26 |
LiYY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.1 |
14.5 |
26 |
LiYY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.2 |
16.7 |
26 |
LiYY TP 12x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.6 |
26 |
LiYY TP 15x2x0.75 |
24/0.20 |
0.5 |
1.4 |
19.6 |
26 |
1.0mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
LiYY TP 3x2x1.0 |
32/0.20 |
0.6 |
1 |
11.4 |
19.5 |
LiYY TP 4x2x1.0 |
32/0.20 |
0.6 |
1 |
12.3 |
19.5 |
LiYY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15.2 |
19.5 |
LiYY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
16.6 |
19.5 |
LiYY TP 10x2x1.0 |
32/0.20 |
0.6 |
1.4 |
19.8 |
19.5 |
1.5mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY TP 2x2x1.5 |
30/0.25 |
0.6 |
1 |
11.5 |
13.3 |
LiYY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
12.7 |
13.3 |
LiYY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
13.9 |
13.3 |
LiYY TP 6x2x1.5 |
30/0.25 |
0.6 |
1.3 |
16.9 |
13.3 |
LiYY TP 8x2x1.5 |
30/0.25 |
0.6 |
1.3 |
18.3 |
13.3 |
Product detail pictures:
Related Product Guide:
We have now probably the most innovative production equipment, experienced and qualified engineers and workers, regarded high quality control systems and also a friendly expert income team pre/after-sales support for Hot-Selling Building Wire - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: South Korea, Croatia, Hungary, We insist on "Quality First, Reputation First and Customer First". We are committed to providing high-quality products and good after-sales services. Up to now, our products have been exported to more than 60 countries and areas around the world, such as America, Australia and Europe. We enjoy a high reputation at home and abroad. Always persisting in the principle of "Credit, Customer and Quality", we expect cooperation with people in all walks of life for mutual benefits.
By Margaret from Seattle - 2017.05.21 12:31
This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
By Patricia from Myanmar - 2017.11.11 11:41