manufacturer BELDEN equivalent type instrument cable BS5308 tinned copper conductor pair screened
Application
Manufactured to PAS5308, Instrumentation cables are intrinsically safe and designed for use in communication and instrumentation applications in and around process industries for transmission of signals in control systems. The signals can be analogue or digital from a variety of sensors and transducers.
Constructions
Conductor: Plain Annealed Copper Conductors
Insulation: Polyvinyl Chloride (PVC)
Arranged: Laid up to form pairs
TAPE: Individual and collective aluminium/mylar tape screen complete with 0.5mm drain wire
Sheath: Polyvinyl Chloride (PVC)
Sheath Colour: Blue or Black
The maximum period of operation is 15years
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 65℃
Rated Voltage: 300/500V
Test Voltage (DC): 2000V Between Conductors
2000V Between Each Conductor and Armour
Reference Standards
BS 5308 PAS5308
BS EN 50265
BS EN/IEC 60332-3-24
Flame propagation to BS4066 Pt1