Manufacturer Of Crimping Data Cable - LiYY TP Multipair Control Cable – AIPU
Manufacturer Of Crimping Data Cable - LiYY TP Multipair Control Cable – AIPU Detail:
Constructions
1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
Section Area |
Rated Voltage |
Test Voltage |
Min. Insulation |
0.14~0.34mm2 |
250/250V |
1.2kV |
200 |
0.5~0.75mm2 |
300V |
2000V |
200 |
1.0~1.5mm2 |
300/500V |
3000V |
200 |
0.14mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.14 |
12/0.12 |
0.35 |
0.4 |
3.2 |
148 |
LiYY TP 2x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.3 |
148 |
LiYY TP 3x2x0.14 |
12/0.12 |
0.35 |
0.6 |
5.7 |
148 |
LiYY TP 4x2x0.14 |
12/0.12 |
0.35 |
0.7 |
6.4 |
148 |
LiYY TP 6x2x0.14 |
12/0.12 |
0.35 |
0.7 |
7.5 |
148 |
LiYY TP 8x2x0.14 |
12/0.12 |
0.35 |
0.8 |
8.6 |
148 |
LiYY TP 10x2x0.14 |
12/0.12 |
0.35 |
0.9 |
10 |
148 |
LiYY TP 12x2x0.14 |
12/0.12 |
0.35 |
1 |
10.4 |
148 |
LiYY TP 15x2x0.14 |
12/0.12 |
0.35 |
1.1 |
11.6 |
148 |
0.25mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.25 |
14/0.15 |
0.4 |
0.4 |
3.6 |
79.9 |
LiYY TP 2x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6 |
79.9 |
LiYY TP 3x2x0.25 |
14/0.15 |
0.4 |
0.6 |
6.4 |
79.9 |
LiYY TP 4x2x0.25 |
14/0.15 |
0.4 |
0.7 |
7.2 |
79.9 |
LiYY TP 6x2x0.25 |
14/0.15 |
0.4 |
0.8 |
8.8 |
79.9 |
LiYY TP 8x2x0.25 |
14/0.15 |
0.4 |
0.8 |
9.8 |
79.9 |
LiYY TP 10x2x0.25 |
14/0.15 |
0.4 |
1 |
11.5 |
79.9 |
LiYY TP 12x2x0.25 |
14/0.15 |
0.4 |
1 |
12.1 |
79.9 |
LiYY TP 15x2x0.25 |
14/0.15 |
0.4 |
1.1 |
13.5 |
79.9 |
0.34mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.34 |
20/0.15 |
0.4 |
0.5 |
4.2 |
57 |
LiYY TP 2x2x0.34 |
20/0.15 |
0.4 |
0.6 |
6.7 |
57 |
LiYY TP 3x2x0.34 |
20/0.15 |
0.4 |
0.6 |
7.2 |
57 |
LiYY TP 4x2x0.34 |
20/0.15 |
0.4 |
0.7 |
8 |
57 |
LiYY TP 6x2x0.34 |
20/0.15 |
0.4 |
0.9 |
10 |
57 |
LiYY TP 8x2x0.34 |
20/0.15 |
0.4 |
1 |
11.4 |
57 |
LiYY TP 10x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.1 |
57 |
LiYY TP 12x2x0.34 |
20/0.15 |
0.4 |
1.1 |
13.4 |
57 |
LiYY TP 15x2x0.34 |
20/0.15 |
0.4 |
1.2 |
14.9 |
57 |
0.50mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.5 |
16/0.20 |
0.45 |
0.6 |
4.8 |
39 |
LiYY TP 2x2x0.5 |
16/0.20 |
0.45 |
0.7 |
7.5 |
39 |
LiYY TP 3x2x0.5 |
16/0.20 |
0.45 |
0.7 |
8.1 |
39 |
LiYY TP 4x2x0.5 |
16/0.20 |
0.45 |
0.8 |
9 |
39 |
LiYY TP 6x2x0.5 |
16/0.20 |
0.45 |
1 |
11.2 |
39 |
LiYY TP 8x2x0.5 |
16/0.20 |
0.45 |
1.1 |
12.8 |
39 |
LiYY TP 10x2x0.5 |
16/0.20 |
0.45 |
1.2 |
14.7 |
39 |
LiYY TP 12x2x0.5 |
16/0.20 |
0.45 |
1.2 |
15 |
39 |
LiYY TP 15x2x0.5 |
16/0.20 |
0.45 |
1.3 |
16.7 |
39 |
0.75mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x0.75 |
24/0.20 |
0.5 |
0.6 |
5.4 |
26 |
LiYY TP 2x2x0.75 |
24/0.20 |
0.5 |
0.7 |
8.6 |
26 |
LiYY TP 3x2x0.75 |
24/0.20 |
0.5 |
0.8 |
9.5 |
26 |
LiYY TP 4x2x0.75 |
24/0.20 |
0.5 |
0.9 |
10.4 |
26 |
LiYY TP 6x2x0.75 |
24/0.20 |
0.5 |
1 |
12.7 |
26 |
LiYY TP 8x2x0.75 |
24/0.20 |
0.5 |
1.1 |
14.5 |
26 |
LiYY TP 10x2x0.75 |
24/0.20 |
0.5 |
1.2 |
16.7 |
26 |
LiYY TP 12x2x0.75 |
24/0.20 |
0.5 |
1.3 |
17.6 |
26 |
LiYY TP 15x2x0.75 |
24/0.20 |
0.5 |
1.4 |
19.6 |
26 |
1.0mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.0 |
32/0.20 |
0.6 |
0.6 |
6.2 |
19.5 |
LiYY TP 2x2x1.0 |
32/0.20 |
0.6 |
0.9 |
10.3 |
19.5 |
LiYY TP 3x2x1.0 |
32/0.20 |
0.6 |
1 |
11.4 |
19.5 |
LiYY TP 4x2x1.0 |
32/0.20 |
0.6 |
1 |
12.3 |
19.5 |
LiYY TP 6x2x1.0 |
32/0.20 |
0.6 |
1.2 |
15.2 |
19.5 |
LiYY TP 8x2x1.0 |
32/0.20 |
0.6 |
1.3 |
16.6 |
19.5 |
LiYY TP 10x2x1.0 |
32/0.20 |
0.6 |
1.4 |
19.8 |
19.5 |
1.5mm2
No. of Pairs |
Conductor Construction (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Overall Diameter (mm) |
Max. DCR at 20℃ (Ω/km) |
LiYY TP 1x2x1.5 |
30/0.25 |
0.6 |
0.6 |
6.8 |
13.3 |
LiYY TP 2x2x1.5 |
30/0.25 |
0.6 |
1 |
11.5 |
13.3 |
LiYY TP 3x2x1.5 |
30/0.25 |
0.6 |
1.1 |
12.7 |
13.3 |
LiYY TP 4x2x1.5 |
30/0.25 |
0.6 |
1.2 |
13.9 |
13.3 |
LiYY TP 6x2x1.5 |
30/0.25 |
0.6 |
1.3 |
16.9 |
13.3 |
LiYY TP 8x2x1.5 |
30/0.25 |
0.6 |
1.3 |
18.3 |
13.3 |
Product detail pictures:
Related Product Guide:
Often customer-oriented, and it's our ultimate target to become not only probably the most reputable, trustable and honest provider, but also the partner for our customers for Manufacturer Of Crimping Data Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Zurich, Bahamas, Nigeria, Our advanced equipment, excellent quality management, research and development ability make our price down. The price we offering may not be the lowest, but we guarantee it is absolutely competitive! Welcome to contact us immediately for future business relationship and mutual success!
By Dawn from Pretoria - 2017.03.07 13:42
The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
By Heloise from New Orleans - 2017.09.29 11:19