New Delivery For Fieldbus Cable - LiYcY TP Multipair Screened Control Cable – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

We always think and practice corresponding to the change of circumstance, and grow up. We purpose at the achievement of a richer mind and body as well as the living for Power Distribution Unit, Data Bus Cable, Network Cabinet, We sincerely welcome overseas customers to consult for the long-term cooperation and the mutual development.We strongly believe that we can do better and better.
New Delivery For Fieldbus Cable - LiYcY TP Multipair Screened Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR at
20℃ (Ω/km)

LiYcY TP 1x2x0.14

12/0.12

0.35

0.7

4.4

148

LiYcY TP 2x2x0.14

12/0.12

0.35

0.7

6.1

148

LiYcY TP 3x2x0.14

12/0.12

0.35

0.8

6.7

148

LiYcY TP 4x2x0.14

12/0.12

0.35

0.8

7.2

148

LiYcY TP 6x2x0.14

12/0.12

0.35

0.8

8.3

148

LiYcY TP 8x2x0.14

12/0.12

0.35

0.8

9.4

148

LiYcY TP 10x2x0.14

12/0.12

0.35

0.9

10.8

148

LiYcY TP 12x2x0.14

12/0.12

0.35

1.0

11.4

148

0.25mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.25

14/0.15

0.4

0.7

4.8

79.9

LiYcY TP 2x2x0.25

14/0.15

0.4

0.8

7

79.9

LiYcY TP 3x2x0.25

14/0.15

0.4

0.8

7.4

79.9

LiYcY TP 4x2x0.25

14/0.15

0.4

0.8

8

79.9

LiYcY TP 6x2x0.25

14/0.15

0.4

0.8

9.6

79.9

LiYcY TP 8x2x0.25

14/0.15

0.4

0.9

10.8

79.9

LiYcY TP 10x2x0.25

14/0.15

0.4

1.0

12.3

79.9

LiYcY TP 12x2x0.25

14/0.15

0.4

1.1

12.6

79.9

0.34mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.34

20/0.15

0.4

0.7

5.2

57

LiYcY TP 2x2x0.34

20/0.15

0.4

0.8

7.7

57

LiYcY TP 3x2x0.34

20/0.15

0.4

0.8

8.2

57

LiYcY TP 4x2x0.34

20/0.15

0.4

0.8

9

57

LiYcY TP 6x2x0.34

20/0.15

0.4

0.9

10.8

57

LiYcY TP 8x2x0.34

20/0.15

0.4

1.0

12.2

57

LiYcY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYcY TP 12x2x0.34

20/0.15

0.4

1.2

14.7

57

0.50mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.5

16/0.20

0.45

0.7

5.6

39

LiYcY TP 2x2x0.5

16/0.20

0.45

0.8

8.3

39

LiYcY TP 3x2x0.5

16/0.20

0.45

0.8

9.1

39

LiYcY TP 4x2x0.5

16/0.20

0.45

0.9

10

39

LiYcY TP 6x2x0.5

16/0.20

0.45

1.0

12

39

LiYcY TP 8x2x0.5

16/0.20

0.45

1.1

13.1

39

LiYcY TP 10x2x0.5

16/0.20

0.45

1.2

15.5

39

0.75mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.75

24/0.20

0.5

0.8

6.4

26

LiYcY TP 2x2x0.75

24/0.20

0.5

0.8

9.6

26

LiYcY TP 3x2x0.75

24/0.20

0.5

0.9

10.5

26

LiYcY TP 4x2x0.75

24/0.20

0.5

1.0

11.4

26

LiYcY TP 6x2x0.75

24/0.20

0.5

1.1

13.7

26

LiYcY TP 8x2x0.75

24/0.20

0.5

1.2

15

26

LiYcY TP 10x2x0.75

24/0.20

0.5

1.3

17.7

26

1.0mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.0

32/0.20

0.6

0.8

7.2

19.5

LiYcY TP 2x2x1.0

32/0.20

0.6

0.9

11.1

19.5

LiYcY TP 3x2x1.0

32/0.20

0.6

1.0

12.2

19.5

LiYcY TP 4x2x1.0

32/0.20

0.6

1.0

13.1

19.5

LiYcY TP 6x2x1.0

32/0.20

0.6

1.2

15

19.5

LiYcY TP 8x2x1.0

32/0.20

0.6

1.3

17.4

19.5

1.5mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.5

30/0.25

0.6

0.8

7.8

13.3

LiYcY TP 2x2x1.5

30/0.25

0.6

1.0

12.3

13.3

LiYcY TP 3x2x1.5

30/0.25

0.6

1.1

13.5

13.3

LiYcY TP 4x2x1.5

30/0.25

0.6

1.2

14.7

13.3


Product detail pictures:

New Delivery For Fieldbus Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures

New Delivery For Fieldbus Cable - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures


Related Product Guide:

With our loaded practical experience and thoughtful solutions, we now have been identified for a trusted provider for numerous intercontinental consumers for New Delivery For Fieldbus Cable - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: Belgium, Germany, Azerbaijan, Our company will continue to adhere to the " superior quality, reputable, the user first " principle wholeheartedly. We warmly welcome friends from all walks of life to visit and give guidance, work together and create a brilliant future!
  • In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Irma from Lithuania - 2017.01.28 18:53
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Isabel from Germany - 2017.08.28 16:02
    Write your message here and send it to us