As a way to ideal meet up with client's desires, all of our operations are strictly performed in line with our motto "High Top quality, Competitive Cost, Fast Service" for Office Server Rack, Server Rack Enclosure, Elv Cable, We warmly welcome business partners from all walks of life, expect to establish friendly and cooperative business contact with you and achieve a win-win goal.
New Fashion Design For Lighting Control Cable - LiYY TP Multipair Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.14

12/0.12

0.35

0.4

3.2

148

LiYY TP 2x2x0.14

12/0.12

0.35

0.6

5.3

148

LiYY TP 3x2x0.14

12/0.12

0.35

0.6

5.7

148

LiYY TP 4x2x0.14

12/0.12

0.35

0.7

6.4

148

LiYY TP 6x2x0.14

12/0.12

0.35

0.7

7.5

148

LiYY TP 8x2x0.14

12/0.12

0.35

0.8

8.6

148

LiYY TP 10x2x0.14

12/0.12

0.35

0.9

10

148

LiYY TP 12x2x0.14

12/0.12

0.35

1

10.4

148

LiYY TP 15x2x0.14

12/0.12

0.35

1.1

11.6

148

0.25mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY TP 2x2x0.25

14/0.15

0.4

0.6

6

79.9

LiYY TP 3x2x0.25

14/0.15

0.4

0.6

6.4

79.9

LiYY TP 4x2x0.25

14/0.15

0.4

0.7

7.2

79.9

LiYY TP 6x2x0.25

14/0.15

0.4

0.8

8.8

79.9

LiYY TP 8x2x0.25

14/0.15

0.4

0.8

9.8

79.9

LiYY TP 10x2x0.25

14/0.15

0.4

1

11.5

79.9

LiYY TP 12x2x0.25

14/0.15

0.4

1

12.1

79.9

LiYY TP 15x2x0.25

14/0.15

0.4

1.1

13.5

79.9

0.34mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.34

20/0.15

0.4

0.5

4.2

57

LiYY TP 2x2x0.34

20/0.15

0.4

0.6

6.7

57

LiYY TP 3x2x0.34

20/0.15

0.4

0.6

7.2

57

LiYY TP 4x2x0.34

20/0.15

0.4

0.7

8

57

LiYY TP 6x2x0.34

20/0.15

0.4

0.9

10

57

LiYY TP 8x2x0.34

20/0.15

0.4

1

11.4

57

LiYY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYY TP 12x2x0.34

20/0.15

0.4

1.1

13.4

57

LiYY TP 15x2x0.34

20/0.15

0.4

1.2

14.9

57

0.50mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.5

16/0.20

0.45

0.6

4.8

39

LiYY TP 2x2x0.5

16/0.20

0.45

0.7

7.5

39

LiYY TP 3x2x0.5

16/0.20

0.45

0.7

8.1

39

LiYY TP 4x2x0.5

16/0.20

0.45

0.8

9

39

LiYY TP 6x2x0.5

16/0.20

0.45

1

11.2

39

LiYY TP 8x2x0.5

16/0.20

0.45

1.1

12.8

39

LiYY TP 10x2x0.5

16/0.20

0.45

1.2

14.7

39

LiYY TP 12x2x0.5

16/0.20

0.45

1.2

15

39

LiYY TP 15x2x0.5

16/0.20

0.45

1.3

16.7

39

0.75mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.75

24/0.20

0.5

0.6

5.4

26

LiYY TP 2x2x0.75

24/0.20

0.5

0.7

8.6

26

LiYY TP 3x2x0.75

24/0.20

0.5

0.8

9.5

26

LiYY TP 4x2x0.75

24/0.20

0.5

0.9

10.4

26

LiYY TP 6x2x0.75

24/0.20

0.5

1

12.7

26

LiYY TP 8x2x0.75

24/0.20

0.5

1.1

14.5

26

LiYY TP 10x2x0.75

24/0.20

0.5

1.2

16.7

26

LiYY TP 12x2x0.75

24/0.20

0.5

1.3

17.6

26

LiYY TP 15x2x0.75

24/0.20

0.5

1.4

19.6

26

1.0mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY TP 2x2x1.0

32/0.20

0.6

0.9

10.3

19.5

LiYY TP 3x2x1.0

32/0.20

0.6

1

11.4

19.5

LiYY TP 4x2x1.0

32/0.20

0.6

1

12.3

19.5

LiYY TP 6x2x1.0

32/0.20

0.6

1.2

15.2

19.5

LiYY TP 8x2x1.0

32/0.20

0.6

1.3

16.6

19.5

LiYY TP 10x2x1.0

32/0.20

0.6

1.4

19.8

19.5

1.5mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY TP 2x2x1.5

30/0.25

0.6

1

11.5

13.3

LiYY TP 3x2x1.5

30/0.25

0.6

1.1

12.7

13.3

LiYY TP 4x2x1.5

30/0.25

0.6

1.2

13.9

13.3

LiYY TP 6x2x1.5

30/0.25

0.6

1.3

16.9

13.3

LiYY TP 8x2x1.5

30/0.25

0.6

1.3

18.3

13.3


Product detail pictures:

New Fashion Design For Lighting Control Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures

New Fashion Design For Lighting Control Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures


Related Product Guide:

Every member from our high efficiency sales team values customers' needs and business communication for New Fashion Design For Lighting Control Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: Portugal, San Diego, Qatar, Our company absorbs new ideas, strict quality control, a full range of service tracking, and adhere to make high-quality products. Our business aims to "honest and trustworthy, favorable price, customer first", so we won the trust of the majority of customers! If you are interested in our products and services, please do not hesitate to contact us!
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Quintina from Kazakhstan - 2017.02.28 14:19
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Norma from Maldives - 2018.10.01 14:14
    Write your message here and send it to us