Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

Sticking for the principle of "Super Quality, Satisfactory service" ,We have been striving for being a superb small business partner of you for Electrical Control Cable, Data Power Cable, Metal Data Cable, The mission of our firm should be to provide the best high quality goods with finest price tag. We've been on the lookout forward to doing organization with you!
Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
4. Screen: Tinned Copper Wire Braided
5. Sheath: LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.14

12/0.12

0.3

0.6

4

148

LiHcH 3×0.14

12/0.12

0.3

0.6

4.2

148

LiHcH 4×0.14

12/0.12

0.3

0.6

4.5

148

LiHcH 5×0.14

12/0.12

0.3

0.6

4.8

148

LiHcH 7×0.14

12/0.12

0.3

0.6

5.1

148

LiHcH 8×0.14

12/0.12

0.3

0.6

5.4

148

LiHcH 10×0.14

12/0.12

0.3

0.6

6.2

148

LiHcH 12×0.14

12/0.12

0.3

0.7

6.6

148

LiHcH 14×0.14

12/0.12

0.3

0.7

6.9

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHcH 3×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHcH 4×0.25

14/0.15

0.3

0.6

5

79.9

LiHcH 5×0.25

14/0.15

0.3

0.6

5.3

79.9

LiHcH 7×0.25

14/0.15

0.3

0.6

5.7

79.9

LiHcH 8×0.25

14/0.15

0.3

0.6

6.1

79.9

LiHcH 10×0.25

14/0.15

0.3

0.7

7.2

79.9

LiHcH 12×0.25

14/0.15

0.3

0.7

7.5

79.9

LiHcH 14×0.25

14/0.15

0.3

0.7

7.8

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.34

20/0.15

0.3

0.6

4.6

57

LiHcH 3×0.34

20/0.15

0.3

0.6

4.9

57

LiHcH 4×0.34

20/0.15

0.3

0.6

5.2

57

LiHcH 5×0.34

20/0.15

0.3

0.6

5.6

57

LiHcH 7×0.34

20/0.15

0.3

0.6

6

57

LiHcH 8×0.34

20/0.15

0.3

0.6

6.4

57

LiHcH 10×0.34

20/0.15

0.3

0.7

7.6

57

LiHcH 12×0.34

20/0.15

0.3

0.7

7.9

57

LiHcH 14×0.34

20/0.15

0.3

0.7

8.2

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.5

16/0.20

0.3

0.6

4.9

39

LiHcH 3×0.5

16/0.20

0.3

0.6

5.2

39

LiHcH 4×0.5

16/0.20

0.3

0.6

5.6

39

LiHcH 5×0.5

16/0.20

0.3

0.6

6

39

LiHcH 7×0.5

16/0.20

0.3

0.6

6.5

39

LiHcH 8×0.5

16/0.20

0.3

0.7

7.1

39

LiHcH 10×0.5

16/0.20

0.3

0.7

8.2

39

LiHcH 12×0.5

16/0.20

0.3

0.7

8.7

39

LiHcH 14×0.5

16/0.20

0.3

0.7

9.1

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.75

24/0.20

0.4

0.6

5.8

26

LiHcH 3×0.75

24/0.20

0.4

0.6

6.2

26

LiHcH 4×0.75

24/0.20

0.4

0.6

6.7

26

LiHcH 5×0.75

24/0.20

0.4

0.7

7.2

26

LiHcH 7×0.75

24/0.20

0.4

0.7

7.8

26

LiHcH 8×0.75

24/0.20

0.4

0.7

8.8

26

LiHcH 10×0.75

24/0.20

0.4

0.8

10.4

26

LiHcH 12×0.75

24/0.20

0.4

0.8

10.8

26

LiHcH 14×0.75

24/0.20

0.4

0.9

11.5

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.0

32/0.20

0.5

0.6

6.4

19.5

LiHcH 3×1.0

32/0.20

0.5

0.6

6.9

19.5

LiHcH 4×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHcH 5×1.0

32/0.20

0.5

0.7

8.2

19.5

LiHcH 7×1.0

32/0.20

0.5

0.9

9.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.5

30/0.25

0.5

0.6

7

13.3

LiHcH 3×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHcH 4×1.5

30/0.25

0.5

0.7

8.3

13.3

LiHcH 5×1.5

30/0.25

0.5

0.8

9.4

13.3

LiHcH 7×1.5

30/0.25

0.5

1.0

10.6

13.3


Product detail pictures:

Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures

Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures


Related Product Guide:

All we do is usually connected with our tenet " Customer to start with, Rely on initial, devoting on the food packaging and environmental protection for Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU , The product will supply to all over the world, such as: Slovenia, Russia, United States, If you are interested in any of our products and solutions or would like to discuss a custom order, remember to feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
  • As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Katherine from Ethiopia - 2017.12.02 14:11
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Kim from Stuttgart - 2017.08.15 12:36
    Write your message here and send it to us