Innovation, excellent and reliability are the core values of our company. These principles today much more than ever form the basis of our success as an internationally active mid-size business for Solid Strand Wire, Empty Patch Panel, Data Cable Wire, Created products with brand value. We attend seriously to produce and behave with integrity, and by the favor of customers at home and abroad in the xxx industry.
Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
4. Screen: Tinned Copper Wire Braided
5. Sheath: LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.14

12/0.12

0.3

0.6

4

148

LiHcH 3×0.14

12/0.12

0.3

0.6

4.2

148

LiHcH 4×0.14

12/0.12

0.3

0.6

4.5

148

LiHcH 5×0.14

12/0.12

0.3

0.6

4.8

148

LiHcH 7×0.14

12/0.12

0.3

0.6

5.1

148

LiHcH 8×0.14

12/0.12

0.3

0.6

5.4

148

LiHcH 10×0.14

12/0.12

0.3

0.6

6.2

148

LiHcH 12×0.14

12/0.12

0.3

0.7

6.6

148

LiHcH 14×0.14

12/0.12

0.3

0.7

6.9

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHcH 3×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHcH 4×0.25

14/0.15

0.3

0.6

5

79.9

LiHcH 5×0.25

14/0.15

0.3

0.6

5.3

79.9

LiHcH 7×0.25

14/0.15

0.3

0.6

5.7

79.9

LiHcH 8×0.25

14/0.15

0.3

0.6

6.1

79.9

LiHcH 10×0.25

14/0.15

0.3

0.7

7.2

79.9

LiHcH 12×0.25

14/0.15

0.3

0.7

7.5

79.9

LiHcH 14×0.25

14/0.15

0.3

0.7

7.8

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.34

20/0.15

0.3

0.6

4.6

57

LiHcH 3×0.34

20/0.15

0.3

0.6

4.9

57

LiHcH 4×0.34

20/0.15

0.3

0.6

5.2

57

LiHcH 5×0.34

20/0.15

0.3

0.6

5.6

57

LiHcH 7×0.34

20/0.15

0.3

0.6

6

57

LiHcH 8×0.34

20/0.15

0.3

0.6

6.4

57

LiHcH 10×0.34

20/0.15

0.3

0.7

7.6

57

LiHcH 12×0.34

20/0.15

0.3

0.7

7.9

57

LiHcH 14×0.34

20/0.15

0.3

0.7

8.2

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.5

16/0.20

0.3

0.6

4.9

39

LiHcH 3×0.5

16/0.20

0.3

0.6

5.2

39

LiHcH 4×0.5

16/0.20

0.3

0.6

5.6

39

LiHcH 5×0.5

16/0.20

0.3

0.6

6

39

LiHcH 7×0.5

16/0.20

0.3

0.6

6.5

39

LiHcH 8×0.5

16/0.20

0.3

0.7

7.1

39

LiHcH 10×0.5

16/0.20

0.3

0.7

8.2

39

LiHcH 12×0.5

16/0.20

0.3

0.7

8.7

39

LiHcH 14×0.5

16/0.20

0.3

0.7

9.1

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.75

24/0.20

0.4

0.6

5.8

26

LiHcH 3×0.75

24/0.20

0.4

0.6

6.2

26

LiHcH 4×0.75

24/0.20

0.4

0.6

6.7

26

LiHcH 5×0.75

24/0.20

0.4

0.7

7.2

26

LiHcH 7×0.75

24/0.20

0.4

0.7

7.8

26

LiHcH 8×0.75

24/0.20

0.4

0.7

8.8

26

LiHcH 10×0.75

24/0.20

0.4

0.8

10.4

26

LiHcH 12×0.75

24/0.20

0.4

0.8

10.8

26

LiHcH 14×0.75

24/0.20

0.4

0.9

11.5

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.0

32/0.20

0.5

0.6

6.4

19.5

LiHcH 3×1.0

32/0.20

0.5

0.6

6.9

19.5

LiHcH 4×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHcH 5×1.0

32/0.20

0.5

0.7

8.2

19.5

LiHcH 7×1.0

32/0.20

0.5

0.9

9.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.5

30/0.25

0.5

0.6

7

13.3

LiHcH 3×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHcH 4×1.5

30/0.25

0.5

0.7

8.3

13.3

LiHcH 5×1.5

30/0.25

0.5

0.8

9.4

13.3

LiHcH 7×1.5

30/0.25

0.5

1.0

10.6

13.3


Product detail pictures:

Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures

Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate inside our success for Oem/Odm China Control Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU , The product will supply to all over the world, such as: Cancun, Dominica, Thailand, Honest to every customers are our requested! First-class serve, best quality, best price and fastest delivery date is our advantage! Give every customers good serve is our tenet! This makes our company get the favour of customers and support! Welcome all over the world customers send us enquiry and looking forward your good co-operation !Please your inquiry for more details or request for dealership in selected regions.
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Dominic from Iraq - 2018.11.06 10:04
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Letitia from Durban - 2017.11.29 11:09
    Write your message here and send it to us