Oem/Odm Factory Building Wire Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

Assume full accountability to fulfill all demands of our purchasers; attain continual advancements by marketing the advancement of our clientele; grow to be the final permanent cooperative partner of purchasers and maximize the interests of purchasers for Server Rack Mounting Rails, Server Rack Power, Standard Server Rack Height, With a wide range, good quality, reasonable prices and good service, we will be your best business partner. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
Oem/Odm Factory Building Wire Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
4. Screen: Tinned Copper Wire Braided
5. Sheath: LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.14

12/0.12

0.3

0.6

4

148

LiHcH 3×0.14

12/0.12

0.3

0.6

4.2

148

LiHcH 4×0.14

12/0.12

0.3

0.6

4.5

148

LiHcH 5×0.14

12/0.12

0.3

0.6

4.8

148

LiHcH 7×0.14

12/0.12

0.3

0.6

5.1

148

LiHcH 8×0.14

12/0.12

0.3

0.6

5.4

148

LiHcH 10×0.14

12/0.12

0.3

0.6

6.2

148

LiHcH 12×0.14

12/0.12

0.3

0.7

6.6

148

LiHcH 14×0.14

12/0.12

0.3

0.7

6.9

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHcH 3×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHcH 4×0.25

14/0.15

0.3

0.6

5

79.9

LiHcH 5×0.25

14/0.15

0.3

0.6

5.3

79.9

LiHcH 7×0.25

14/0.15

0.3

0.6

5.7

79.9

LiHcH 8×0.25

14/0.15

0.3

0.6

6.1

79.9

LiHcH 10×0.25

14/0.15

0.3

0.7

7.2

79.9

LiHcH 12×0.25

14/0.15

0.3

0.7

7.5

79.9

LiHcH 14×0.25

14/0.15

0.3

0.7

7.8

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.34

20/0.15

0.3

0.6

4.6

57

LiHcH 3×0.34

20/0.15

0.3

0.6

4.9

57

LiHcH 4×0.34

20/0.15

0.3

0.6

5.2

57

LiHcH 5×0.34

20/0.15

0.3

0.6

5.6

57

LiHcH 7×0.34

20/0.15

0.3

0.6

6

57

LiHcH 8×0.34

20/0.15

0.3

0.6

6.4

57

LiHcH 10×0.34

20/0.15

0.3

0.7

7.6

57

LiHcH 12×0.34

20/0.15

0.3

0.7

7.9

57

LiHcH 14×0.34

20/0.15

0.3

0.7

8.2

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.5

16/0.20

0.3

0.6

4.9

39

LiHcH 3×0.5

16/0.20

0.3

0.6

5.2

39

LiHcH 4×0.5

16/0.20

0.3

0.6

5.6

39

LiHcH 5×0.5

16/0.20

0.3

0.6

6

39

LiHcH 7×0.5

16/0.20

0.3

0.6

6.5

39

LiHcH 8×0.5

16/0.20

0.3

0.7

7.1

39

LiHcH 10×0.5

16/0.20

0.3

0.7

8.2

39

LiHcH 12×0.5

16/0.20

0.3

0.7

8.7

39

LiHcH 14×0.5

16/0.20

0.3

0.7

9.1

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.75

24/0.20

0.4

0.6

5.8

26

LiHcH 3×0.75

24/0.20

0.4

0.6

6.2

26

LiHcH 4×0.75

24/0.20

0.4

0.6

6.7

26

LiHcH 5×0.75

24/0.20

0.4

0.7

7.2

26

LiHcH 7×0.75

24/0.20

0.4

0.7

7.8

26

LiHcH 8×0.75

24/0.20

0.4

0.7

8.8

26

LiHcH 10×0.75

24/0.20

0.4

0.8

10.4

26

LiHcH 12×0.75

24/0.20

0.4

0.8

10.8

26

LiHcH 14×0.75

24/0.20

0.4

0.9

11.5

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.0

32/0.20

0.5

0.6

6.4

19.5

LiHcH 3×1.0

32/0.20

0.5

0.6

6.9

19.5

LiHcH 4×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHcH 5×1.0

32/0.20

0.5

0.7

8.2

19.5

LiHcH 7×1.0

32/0.20

0.5

0.9

9.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.5

30/0.25

0.5

0.6

7

13.3

LiHcH 3×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHcH 4×1.5

30/0.25

0.5

0.7

8.3

13.3

LiHcH 5×1.5

30/0.25

0.5

0.8

9.4

13.3

LiHcH 7×1.5

30/0.25

0.5

1.0

10.6

13.3


Product detail pictures:

Oem/Odm Factory Building Wire Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures

Oem/Odm Factory Building Wire Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures


Related Product Guide:

We have now sophisticated machines. Our solutions are exported to the USA, the UK and so on, enjoying a great reputation amid consumers for Oem/Odm Factory Building Wire Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU , The product will supply to all over the world, such as: Malta, Hongkong, Slovenia, Our domestic website's generated over 50, 000 purchasing orders every year and quite successful for internet shopping in Japan. We would be happy to have an opportunity to do business with your company. Looking forward to receiving your message !
  • In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Lorraine from Bhutan - 2017.03.28 16:34
    Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Zoe from Switzerland - 2018.11.28 16:25
    Write your message here and send it to us