Online Exporter Multi Data Cable - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU
Online Exporter Multi Data Cable - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU Detail:
Application
1. The cable is designed for MS, Sound, Audio, Security, Safety, Control and Instrumentation application indoor & outdoor. Multi-pair cables are available. It could be widely used for production process control and Device Converter audio instrument.
2. Individually Screened, Al-PET tape with Tinned Copper Drain Wire shielded are optional.
3. PVC or LSZH sheath are both available.
4. Instrumentation cable is a multi-conductor cable, generally single or multiple pairs, used for monitoring or controlling the transmission of power and electrical signals related to the process.
5. Instrumentation cables connect instrumentation to electrical equipment, and in industrial equipment, control processes are signals generated by sensors that are transmitted through panels, controllers, and other equipment.
6. The twist pair cables can reduce external interference or internal crosstalk. Single pair shielding is usually the transmission of analog signals. Overall shielding is generally the transmission of digital signals. Meter cable is mainly used in industrial petroleum, mining, chemical and other need process control or measurement automation plants.
Constructions
1. Conductor: Stranded Tinned Copper Wire
2. Insulation: Polyolefin, PVC
3. Cabling: Twist Pairs laying-up
4. Screened: Individually Screened (Optional)
Al-PET tape with Tinned Copper Drain Wire
5. Sheath: PVC/LSZH
Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃
Reference Standards
BS EN 60228
BS EN 50290
RoHS Directives
IEC60332-1
Identification of Insulation
Operating Voltage |
300V, 600V |
Test Voltage |
1.0 KVdc |
Conductor DCR |
91.80 Ω/km (Max. @ 20°C) for 24AWG |
57.0 Ω/km (Max. @ 20°C) for 22AWG |
|
39.50 Ω/km (Max. @ 20°C) for 20AWG |
|
25.0 Ω/km (Max. @ 20°C) for 18AWG |
|
14.0 Ω/km (Max. @ 20°C) for 16AWG |
|
9.3 Ω/km (Max. @ 20°C) for 14AWG |
|
Insulation Resistance |
100 MΩhms/km (Min.) |
Part No. |
Conductor Construction |
Insulation |
Screen |
Sheath |
|
Material |
Size |
||||
AP9414 |
TC |
1x2x22AWG |
PVC |
Al-foil |
PVC |
AP8761 |
TC |
1x2x22AWG |
S-PE |
Al-foil |
PVC |
AP8761NH |
TC |
1x2x22AWG |
S-PP |
Al-foil |
LSZH |
AP9451 |
TC |
1x2x22AWG |
S-PP |
Al-foil |
PVC |
AP8451 |
|||||
AP1266A |
|||||
AP1503A |
TC |
1x2x22AWG |
PVC |
Al-foil |
PVC |
AP9154 |
TC |
1x2x20AWG |
PVC |
Al-foil |
PVC |
AP8762 |
TC |
1x2x20AWG |
S-PE |
Al-foil |
PVC |
AP8762NH |
TC |
1x2x20AWG |
S-PE |
Al-foil |
LSZH |
AP8760 |
TC |
1x2x18AWG |
S-PE |
Al-foil |
PVC |
AP9460 |
|||||
AP8760NH |
TC |
1x2x18AWG |
S-PE |
Al-foil |
LSZH |
AP8719 |
TC |
1x2x16AWG |
S-PE |
Al-foil |
PVC |
AP8719NH |
TC |
1x2x16AWG |
S-PE |
Al-foil |
LSZH |
AP8720 |
TC |
1x2x14AWG |
S-PE |
Al-foil |
PVC |
AP8718 |
TC |
1x2x12AWG |
S-PE |
Al-foil |
PVC |
AP9302 |
TC |
2x2x22AWG |
PVC |
Al-foil |
PVC |
AP9305 |
TC |
4x2x22AWG |
PVC |
Al-foil |
PVC |
AP9306 |
TC |
6x2x22AWG |
PVC |
Al-foil |
PVC |
AP9309 |
TC |
9x2x22AWG |
PVC |
Al-foil |
PVC |
AP1508A |
TC |
1x2x24AWG |
S-PE |
Al-foil |
PVC |
AP8641 |
TC |
1x2x24AWG |
S-PE |
Al-foil |
PVC |
AP1883A |
TC |
1x2x24AWG |
S-PP |
Al-foil |
PVC |
AP9990 |
TC |
3x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9991 |
TC |
6x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9992 |
TC |
9x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP9993 |
TC |
12x2x24AWG |
S-PE |
IS Al-foil |
PVC |
AP8767 |
TC |
3x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8768 |
TC |
6x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8764 |
TC |
9x2x22AWG |
PVC |
IS Al-foil |
PVC |
AP8723 |
TC |
2x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8723NH |
TC |
2x2x22AWG |
S-PP |
IS Al-foil |
LSZH |
AP8778 |
TC |
6x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8774 |
TC |
9x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP8775 |
TC |
11x2x22AWG |
S-PP |
IS Al-foil |
PVC |
AP9402 |
TC |
2x2x20AWG |
PVC |
IS Al-foil |
PVC |
AP9883 |
TC |
3x2x20AWG |
S-PP |
IS Al-foil |
PE |
AP9886 |
TC |
6x2x20AWG |
S-PP |
IS Al-foil |
PE |
AP9873 |
TC |
3x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9874 |
TC |
6x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9875 |
TC |
9x2x20AWG |
S-PP |
IS Al-foil |
PVC |
AP9773 |
TC |
3x2x18AWG |
S-PP |
IS Al-foil |
PVC |
AP9774 |
TC |
6x2x18AWG |
S-PP |
IS Al-foil |
PVC |
AP9775 |
TC |
9x2x18AWG |
S-PP |
IS Al-foil |
PVC |
(Notes: Other cores are available upon request.)
Product detail pictures:
Related Product Guide:
We thinks what customers think, the urgency of urgency to act in the interests of a customer position of principle, allowing for better quality, lower processing costs, prices are more reasonable, won the new and old customers the support and affirmation for Online Exporter Multi Data Cable - Audio, Control and Instrumentation Cables (Multi-Pair, Shielded) – AIPU , The product will supply to all over the world, such as: The Swiss, Saudi Arabia, Hongkong, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information and we will offer you competitive price list then.
By Eunice from New Zealand - 2018.11.02 11:11
Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
By Martha from Ireland - 2017.05.02 11:33