PAS5308 Galvanised Steel Wire Arhoured Instrumentation Cables To Connect Electrical Instrumentation And Communication Systems

Application

Manufactured to PAS5308, Instrumentation cables are intrinsically safe and designed for use in communication and instrumentation applications in and around process industries for transmission of signals in control systems. The signals can be analogue or digital from a variety of sensors and transducers.

 

 

 

 

 


  • OEM : Acceptable
  • MOQ : 10Km
  • Trade Terms: Exw;FOB;CFR;CIF;DAP
  • Payment Terms: T/T;L/C;Negotiable
  • Lead Time: 4-8weeks
  • Reference Standards: Flame propagation to BS4066 Pt 1 & 3 ;PAS5308;BS 50265;BS EN 50266;BS EN/IEC 60332-3-24
  • Product Detail

    Product Tags

    Constructions

    Conductor: Plain Annealed Copper Conductors

    Insulation: Polyethylene (PET) Laid up to form pairs

    Screen: Each pair individually aluminium/mylar foil tape screened, collective aluminium/mylar foil tape screen complete with 0.5mm drain wire Bedding: Polyethylene (PET)

    Armour: Galvanised Steel Wire

    Sheath: Polyvinyl Chloride (PVC)

    Sheath Colour: Blue or Black

    The maximum period of operation is 15years

    Installation Temperature: Above 0℃

    Operating Temperature: -15℃ ~ 65℃

    Rated Voltage: 300/500V

    Test Voltage (DC): 2000V Between Conductors

    2000V Between Each Conductor and Armour

     

    General Characteristics

    Conductor Size (mm2)

    Conductor Class

    Max. DCR (Ω/km)

    Max. Mutual Capacitance Values pF/m

    Max. Capacitance Unbalance at 1KHz (pF/250m)

    Max.L/R Ratio (μH/Ω)

    Cables with Collective Screens (except 1pair & 2pairs)

    1Pair & 2Pairs Cables Collectively Screened & All Cables with Individual Pair Screens

    0.5

    1

    36.8

    75

    115

    250

    25

    1.0

    1

    18.4

    75

    115

    250

    25

    0.5

    5

    39.7

    75

    115

    250

    25

    1.5

    2

    12.3

    85

    120

    250

    40

     Identification of Cable Pairs

    Pair No.

    Colour

    Pair No.

    Colour

    1

    Black

    Blue

    11

    Black

    Red

    2

    Black

    Green

    12

    Blue

    Red

    3

    Blue

    Green

    13

    Green

    Red

    4

    Black

    Brown

    14

    Brown

    Red

    5

    Blue

    Brown

    15

    White

    Red

    6

    Green

    Brown

    16

    Black

    Orange

    7

    Black

    White

    17

    Blue

    Orange

    8

    Blue

    White

    18

    Green

    Orange

    9

    Green

    White

    19

    Brown

    Orange

    10

    Brown

    White

    20

    White

    Orange

     PAS/BS5308 Part 1 Type 2: Collectively Screened Armoured

    No. of Pairs

    Conductor

    Insulation Thickness (mm)

    Sheath Thickness (mm)

    Overall Diameter (mm)

    Size (mm2)

    Class

    1

    0.5

    1

    0.5

    1.3

    9.7

    2

    0.5

    1

    0.5

    1.3

    10.5

    5

    0.5

    1

    0.5

    1.4

    15.2

    10

    0.5

    1

    0.5

    1.6

    19.7

    15

    0.5

    1

    0.5

    1.6

    21.8

    20

    0.5

    1

    0.5

    1.7

    25.0

    1

    1

    1

    0.6

    1.3

    10.8

    2

    1

    1

    0.6

    1.4

    12.0

    5

    1

    1

    0.6

    1.5

    18.7

    10

    1

    1

    0.6

    1.7

    23.3

    15

    1

    1

    0.6

    1.8

    27.1

    20

    1

    1

    0.6

    1.8

    30.2

    1

    0.5

    5

    0.6

    1.3

    10.4

    2

    0.5

    5

    0.6

    1.3

    11.3

    5

    0.5

    5

    0.6

    1.5

    16.9

    10

    0.5

    5

    0.6

    1.6

    21.9

    15

    0.5

    5

    0.6

    1.7

    25.4

    20

    0.5

    5

    0.6

    1.8

    28.1

    1

    1.5

    2

    0.6

    1.4

    11.9

    2

    1.5

    2

    0.6

    1.4

    13.3

    5

    1.5

    2

    0.6

    1.6

    21.1

    10

    1.5

    2

    0.6

    1.8

    27.4

    15

    1.5

    2

    0.6

    1.9

    31.2

    20

    1.5

    2

    0.6

    2

    34.7

     PAS/BS5308 Part 1 Type 2: Individually & Collectively Screened Armoured

    No. of Pairs

    Conductor

    Insulation Thickness (mm)

    Sheath Thickness (mm)

    Overall Diameter (mm)

    Size (mm2)

    Class

    2

    0.5

    1

    0.5

    1.4

    13.1

    5

    0.5

    1

    0.5

    1.5

    15.7

    10

    0.5

    1

    0.5

    1.6

    21.3

    15

    0.5

    1

    0.5

    1.7

    24.7

    20

    0.5

    1

    0.5

    1.8

    27.2

    2

    1

    1

    0.6

    1.4

    14.9

    5

    1

    1

    0.6

    1.5

    19.0

    10

    1

    1

    0.6

    1.7

    26.0

    15

    1

    1

    0.6

    1.8

    29.5

    20

    1

    1

    0.6

    1.9

    32.7

    2

    0.5

    5

    0.6

    1.4

    14.3

    5

    0.5

    5

    0.6

    1.5

    18.1

    10

    0.5

    5

    0.6

    1.7

    24.6

    15

    0.5

    5

    0.6

    1.8

    27.7

    20

    0.5

    5

    0.6

    1.9

    30.6

    2

    1.5

    2

    0.6

    1.5

    17.6

    5

    1.5

    2

    0.6

    1.6

    21.5

    10

    1.5

    2

    0.6

    1.8

    29.7

    15

    1.5

    2

    0.6

    1.9

    33.6

    20

    1.5

    2

    0.6

    2.1

    38.3

     


  • Previous:
  • Next:

  • Write your message here and send it to us