To continuously increase the administration process by virtue of the rule of "sincerely, good religion and excellent are the base of company development", we commonly absorb the essence of linked goods internationally, and continually build new solutions to fulfill the requires of shoppers for Tall Server Cabinet, Network Cable, Delta Plc Communication Cable, If you have any comments about our company or products, please feel free to contact us, your coming mail will be highly appreciated.
Pricelist For Unshielded Ethernet Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
4. Screen: Tinned Copper Wire Braided
5. Sheath: LSZH

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.14

12/0.12

0.3

0.6

4

148

LiHcH 3×0.14

12/0.12

0.3

0.6

4.2

148

LiHcH 4×0.14

12/0.12

0.3

0.6

4.5

148

LiHcH 5×0.14

12/0.12

0.3

0.6

4.8

148

LiHcH 7×0.14

12/0.12

0.3

0.6

5.1

148

LiHcH 8×0.14

12/0.12

0.3

0.6

5.4

148

LiHcH 10×0.14

12/0.12

0.3

0.6

6.2

148

LiHcH 12×0.14

12/0.12

0.3

0.7

6.6

148

LiHcH 14×0.14

12/0.12

0.3

0.7

6.9

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHcH 3×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHcH 4×0.25

14/0.15

0.3

0.6

5

79.9

LiHcH 5×0.25

14/0.15

0.3

0.6

5.3

79.9

LiHcH 7×0.25

14/0.15

0.3

0.6

5.7

79.9

LiHcH 8×0.25

14/0.15

0.3

0.6

6.1

79.9

LiHcH 10×0.25

14/0.15

0.3

0.7

7.2

79.9

LiHcH 12×0.25

14/0.15

0.3

0.7

7.5

79.9

LiHcH 14×0.25

14/0.15

0.3

0.7

7.8

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.34

20/0.15

0.3

0.6

4.6

57

LiHcH 3×0.34

20/0.15

0.3

0.6

4.9

57

LiHcH 4×0.34

20/0.15

0.3

0.6

5.2

57

LiHcH 5×0.34

20/0.15

0.3

0.6

5.6

57

LiHcH 7×0.34

20/0.15

0.3

0.6

6

57

LiHcH 8×0.34

20/0.15

0.3

0.6

6.4

57

LiHcH 10×0.34

20/0.15

0.3

0.7

7.6

57

LiHcH 12×0.34

20/0.15

0.3

0.7

7.9

57

LiHcH 14×0.34

20/0.15

0.3

0.7

8.2

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.5

16/0.20

0.3

0.6

4.9

39

LiHcH 3×0.5

16/0.20

0.3

0.6

5.2

39

LiHcH 4×0.5

16/0.20

0.3

0.6

5.6

39

LiHcH 5×0.5

16/0.20

0.3

0.6

6

39

LiHcH 7×0.5

16/0.20

0.3

0.6

6.5

39

LiHcH 8×0.5

16/0.20

0.3

0.7

7.1

39

LiHcH 10×0.5

16/0.20

0.3

0.7

8.2

39

LiHcH 12×0.5

16/0.20

0.3

0.7

8.7

39

LiHcH 14×0.5

16/0.20

0.3

0.7

9.1

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×0.75

24/0.20

0.4

0.6

5.8

26

LiHcH 3×0.75

24/0.20

0.4

0.6

6.2

26

LiHcH 4×0.75

24/0.20

0.4

0.6

6.7

26

LiHcH 5×0.75

24/0.20

0.4

0.7

7.2

26

LiHcH 7×0.75

24/0.20

0.4

0.7

7.8

26

LiHcH 8×0.75

24/0.20

0.4

0.7

8.8

26

LiHcH 10×0.75

24/0.20

0.4

0.8

10.4

26

LiHcH 12×0.75

24/0.20

0.4

0.8

10.8

26

LiHcH 14×0.75

24/0.20

0.4

0.9

11.5

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.0

32/0.20

0.5

0.6

6.4

19.5

LiHcH 3×1.0

32/0.20

0.5

0.6

6.9

19.5

LiHcH 4×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHcH 5×1.0

32/0.20

0.5

0.7

8.2

19.5

LiHcH 7×1.0

32/0.20

0.5

0.9

9.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHcH 2×1.5

30/0.25

0.5

0.6

7

13.3

LiHcH 3×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHcH 4×1.5

30/0.25

0.5

0.7

8.3

13.3

LiHcH 5×1.5

30/0.25

0.5

0.8

9.4

13.3

LiHcH 7×1.5

30/0.25

0.5

1.0

10.6

13.3


Product detail pictures:

Pricelist For Unshielded Ethernet Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures

Pricelist For Unshielded Ethernet Cable - LiHcH Screened Multicore Control Cable (LSZH)  – AIPU detail pictures


Related Product Guide:

We also provide item sourcing and flight consolidation solutions. We have now our very own manufacturing facility and sourcing place of work. We could provide you with nearly every kind of merchandise associated to our merchandise variety for Pricelist For Unshielded Ethernet Cable - LiHcH Screened Multicore Control Cable (LSZH) – AIPU , The product will supply to all over the world, such as: Korea, Gabon, Iraq, Selling our products causes no risks and brings high returns to your company instead. It is our consistent pursuit to create value for clients. Our company is looking for agents sincerely. What are you waiting for? Come and join us. Now or never.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Christopher Mabey from Tunisia - 2018.09.12 17:18
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Dana from Salt Lake City - 2017.09.28 18:29
    Write your message here and send it to us