Using a complete scientific high quality management program, superior high quality and superior faith, we acquire great reputation and occupied this industry for Communication Wire, Modular Jack Cable, Pdu, We welcome buyers, business enterprise associations and good friends from all sections in the planet to get hold of us and request cooperation for mutual gains.
Professional Design Signal Cable Connector - LiYcY TP Multipair Screened Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Tinned Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Screen: Tinned Copper Wire Braided
6. Sheath: PVC

Installation Temperature: Above 0ºC
Operating Temperature: -15ºC ~ 70ºC

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR at
20℃ (Ω/km)

LiYcY TP 1x2x0.14

12/0.12

0.35

0.7

4.4

148

LiYcY TP 2x2x0.14

12/0.12

0.35

0.7

6.1

148

LiYcY TP 3x2x0.14

12/0.12

0.35

0.8

6.7

148

LiYcY TP 4x2x0.14

12/0.12

0.35

0.8

7.2

148

LiYcY TP 6x2x0.14

12/0.12

0.35

0.8

8.3

148

LiYcY TP 8x2x0.14

12/0.12

0.35

0.8

9.4

148

LiYcY TP 10x2x0.14

12/0.12

0.35

0.9

10.8

148

LiYcY TP 12x2x0.14

12/0.12

0.35

1.0

11.4

148

0.25mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.25

14/0.15

0.4

0.7

4.8

79.9

LiYcY TP 2x2x0.25

14/0.15

0.4

0.8

7

79.9

LiYcY TP 3x2x0.25

14/0.15

0.4

0.8

7.4

79.9

LiYcY TP 4x2x0.25

14/0.15

0.4

0.8

8

79.9

LiYcY TP 6x2x0.25

14/0.15

0.4

0.8

9.6

79.9

LiYcY TP 8x2x0.25

14/0.15

0.4

0.9

10.8

79.9

LiYcY TP 10x2x0.25

14/0.15

0.4

1.0

12.3

79.9

LiYcY TP 12x2x0.25

14/0.15

0.4

1.1

12.6

79.9

0.34mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.34

20/0.15

0.4

0.7

5.2

57

LiYcY TP 2x2x0.34

20/0.15

0.4

0.8

7.7

57

LiYcY TP 3x2x0.34

20/0.15

0.4

0.8

8.2

57

LiYcY TP 4x2x0.34

20/0.15

0.4

0.8

9

57

LiYcY TP 6x2x0.34

20/0.15

0.4

0.9

10.8

57

LiYcY TP 8x2x0.34

20/0.15

0.4

1.0

12.2

57

LiYcY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYcY TP 12x2x0.34

20/0.15

0.4

1.2

14.7

57

0.50mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.5

16/0.20

0.45

0.7

5.6

39

LiYcY TP 2x2x0.5

16/0.20

0.45

0.8

8.3

39

LiYcY TP 3x2x0.5

16/0.20

0.45

0.8

9.1

39

LiYcY TP 4x2x0.5

16/0.20

0.45

0.9

10

39

LiYcY TP 6x2x0.5

16/0.20

0.45

1.0

12

39

LiYcY TP 8x2x0.5

16/0.20

0.45

1.1

13.1

39

LiYcY TP 10x2x0.5

16/0.20

0.45

1.2

15.5

39

0.75mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x0.75

24/0.20

0.5

0.8

6.4

26

LiYcY TP 2x2x0.75

24/0.20

0.5

0.8

9.6

26

LiYcY TP 3x2x0.75

24/0.20

0.5

0.9

10.5

26

LiYcY TP 4x2x0.75

24/0.20

0.5

1.0

11.4

26

LiYcY TP 6x2x0.75

24/0.20

0.5

1.1

13.7

26

LiYcY TP 8x2x0.75

24/0.20

0.5

1.2

15

26

LiYcY TP 10x2x0.75

24/0.20

0.5

1.3

17.7

26

1.0mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.0

32/0.20

0.6

0.8

7.2

19.5

LiYcY TP 2x2x1.0

32/0.20

0.6

0.9

11.1

19.5

LiYcY TP 3x2x1.0

32/0.20

0.6

1.0

12.2

19.5

LiYcY TP 4x2x1.0

32/0.20

0.6

1.0

13.1

19.5

LiYcY TP 6x2x1.0

32/0.20

0.6

1.2

15

19.5

LiYcY TP 8x2x1.0

32/0.20

0.6

1.3

17.4

19.5

1.5mm2

No. of Pairs

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiYcY TP 1x2x1.5

30/0.25

0.6

0.8

7.8

13.3

LiYcY TP 2x2x1.5

30/0.25

0.6

1.0

12.3

13.3

LiYcY TP 3x2x1.5

30/0.25

0.6

1.1

13.5

13.3

LiYcY TP 4x2x1.5

30/0.25

0.6

1.2

14.7

13.3


Product detail pictures:

Professional Design Signal Cable Connector - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures

Professional Design Signal Cable Connector - LiYcY TP Multipair Screened Control Cable  – AIPU detail pictures


Related Product Guide:

Being supported by an highly developed and skilled IT group, we could offer you technical support on pre-sales & after-sales support for Professional Design Signal Cable Connector - LiYcY TP Multipair Screened Control Cable – AIPU , The product will supply to all over the world, such as: Poland, Bogota, South Korea, We follow superior mechanism to process these goods that ensure optimum durability and reliability of the goods. We follow latest effective washing and straightening processes that enable us to supply unmatched quality of items for our clients. We continually strive for perfection and all our efforts are directed towards attaining complete client satisfaction.
  • This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Cora from Peru - 2018.12.30 10:21
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Prudence from Greek - 2018.06.21 17:11
    Write your message here and send it to us