Re-Y (st) Y Pimf Stranded Individual and Overall Screen Instrumentation Cable En50288-7 Copper Wire Manufacturer Factory Price

These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.


Product Detail

Product Tags

CABLE CONSTRUCTION

Conductor    Stranded,annealed plain copper wires to IEC 60228 Class 2 /Class 1/ Class 5 / or tinned on request

Insulation     PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores

Binder Tape   Polyester foil on each twisted triad

Individual Screen  Aluminum/polyester foil with  a tinned copper drain wire  in direct contact with the metallic side of the foil

Binder Tape   Polyester foil on overall cable core formed by stranded triples

Collective Screen   Aluminum/polyester foil with  a tinned copper drain wire  in direct contact with  the metallic side of the foil

Sheath       PVC compound to EN50290-2-22 Blue for intrinsically safe cable, Black for UV resistant

 

STANDARDS & MAIN CHARACTERISTICS

Rated Voltage                                                      500 V

Test Voltage                                                        2000 V (core:core / core: screen)

Working Temperature                                               -15℃ / + 70℃ (during operation)

-5℃ / + 50℃ (during installation)

 

Min Bending Radius (Fixed)                                          7,5 x D

Construction                                                        EN 50288-7

Material                                                            Types & Tests EN 50290-2

Electrical & Mechanical Tests                                         EN 50289

 

APPLICATION

These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

 

ELECTRICAL CHARACTERISTICS

Conductor size (Class 2) nom. mm2 0,5 0,75 1 1,5 2,5
Conductor resistance max. Ω/km 36,7 25,0 18,5 12,3 7,6
Insulation resistance min. MΩ*km 100
Mutual Capacitance max. nF/km 250
Inductance max. mH/km 1
L/R ratio max. µH/Ω 25 25 25 40 60

 

 

PHYSICAL CHARACTERISTICS

Pairs no x Pair x Cross Sectional Area  ( mm2 )

Nominal  Overall   Diameter ( mm )

Approximate Weight                   ( kg/km )

2x2x0,5 10,1 102
4x2x0,5 11,7 156
5x2x0,5 13,0 190
6x2x0,5 14,1 220
8x2x0,5 16,0 284
10x2x0,5 18,2 351
2x2x0,75 11,2 122
4x2x0,75 13,2 197
5x2x0,75 14,4 234
6x2x0,75 16,0 279
8x2x0,75 18,1 360
10x2x0,75 20,6 445
2x2x1 11,6 133
4x2x1 13,7 218
5x2x1 15,0 260
6x2x1 16,5 310
8x2x1 18,7 400
10x2x1 21,4 532
2x2x1,5 13,0 168
4x2x1,5 15,2 279
5x2x1,5 16,6 334
6x2x1,5 18,3 398
8x2x1,5 20,8 515
10x2x1,5 23,8 638
2x2x2,5 15,3 234
4x2x2,5 18,1 395
5x2x2,5 19,8 475
6x2x2,5 21,8 566
8x2x2,5 24,8 734
10x2x2,5 28,4 911

  • Previous:
  • Next:

  • Write your message here and send it to us