Re-Y (st) Y Timf Stranded Annealed Plain Copper Wire Individual and Overall Screen Instrumentation Cable En50288-7 Electrical Wire

These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.


Product Detail

Product Tags

CABLE CONSTRUCTION

Conductor    Stranded,annealed plain copper wires to IEC 60228 Class 2 /Class 1/ Class 5 / or tinned on request

Insulation     PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores

Binder Tape   Polyester foil on each twisted triad

Individual Screen  Aluminum/polyester foil with  a tinned copper drain wire  in direct contact with the metallic side of the foil

Binder Tape   Polyester foil on overall cable core formed by stranded triples

Collective Screen   Aluminum/polyester foil with  a tinned copper drain wire  in direct contact with  the metallic side of the foil

Sheath       PVC compound to EN50290-2-22 Blue for intrinsically safe cable Black for UV resistant

 

STANDARDS & MAIN CHARACTERISTICS

Rated Voltage                                                      500 V

Test Voltage                                                        2000 V (core:core / core: screen)

Working Temperature                                               -15℃ / + 70℃ (during operation)

-5℃ / + 50℃ (during installation)

 

Min Bending Radius (Fixed)                                          7,5 x D

Construction                                                        EN 50288-7

Material                                                            Types & Tests EN 50290-2

Electrical & Mechanical Tests                                         EN 50289

 

APPLICATION

These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

ELECTRICAL CHARACTERISTICS

Conductor size (Class 2) nom. mm2 0,5 0,75 1 1,5 2,5
Conductor resistance max. Ω/km 36,7 25,0 18,5 12,3 7,6
Insulation resistance min. MΩ*km 100
Mutual Capacitance max. nF/km 250
Inductance max. mH/km 1
L/R ratio max. µH/Ω 25 25 25 40 60

 

PHYSICAL CHARACTERISTICS

 

Triple no x Triple x Cross Sectional Area  ( mm2 )

Nominal  Overall   Diameter ( mm )

Approximate Weight                   ( kg/km )

2x3x0,5 11,0 123
4x3x0,5 13,0 201
5x3x0,5 14,2 240
6x3x0,5 15,6 285
8x3x0,5 17,5 360
10x3x0,5 20,1 447
2x3x0,75 12,1 150
4x3x0,75 14,4 251
5x3x0,75 15,9 307
6x3x0,75 17,3 358
8x3x0,75 19,7 464
10x3x0,75 22,5 575
2x3x1 12,7 172
4x3x1 14,8 280
5x3x1 16,4 344
6x3x1 18,1 410
8x3x1 20,3 521
10x3x1 23,5 659
2x3x1,5 14,0 214
4x3x1,5 16,6 366
5x3x1,5 18,4 450
6x3x1,5 20,1 526
8x3x1,5 22,8 684
10x3x1,5 26,3 962
2x3x2,5 16,7 304
4x3x2,5 19,8 528
5x3x2,5 21,9 650
6x3x2,5 24,1 775
8x3x2,5 27,4 1010
10x3x2,5 31,6 1267