Renewable Design For Push Pull Control Cables - LiHH Multicore Control Cable (Halogen Free) – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

It is a good way to enhance our products and solutions and repair. Our mission will be to build creative solutions to consumers with a great experience for Full Server Rack, Fastest Data Cable, Computer Data Cable, And we can help looking for any products of the customers' needs. Make sure provide the best Service, the Best Quality, The fast Delivery.
Renewable Design For Push Pull Control Cables - LiHH Multicore Control Cable (Halogen Free) – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PE
3. Identification: Colored
5. Sheath: LSZH

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1
IEC60754

Section Area

Rated Voltage

Test Voltage

Min. Insulation Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.14

12/0.12

0.3

0.6

3.4

148

LiHH 3×0.14

12/0.12

0.3

0.6

3.6

148

LiHH 4×0.14

12/0.12

0.3

0.6

3.9

148

LiHH 5×0.14

12/0.12

0.3

0.6

4.2

148

LiHH 7×0.14

12/0.12

0.3

0.6

4.5

148

LiHH 8×0.14

12/0.12

0.3

0.6

4.8

148

LiHH 10×0.14

12/0.12

0.3

0.6

5.6

148

LiHH 12×0.14

12/0.12

0.3

0.7

6

148

LiHH 14×0.14

12/0.12

0.3

0.7

6.3

148

0.25mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.25

14/0.15

0.3

0.6

3.8

79.9

LiHH 3×0.25

14/0.15

0.3

0.6

4.1

79.9

LiHH 4×0.25

14/0.15

0.3

0.6

4.4

79.9

LiHH 5×0.25

14/0.15

0.3

0.6

4.7

79.9

LiHH 7×0.25

14/0.15

0.3

0.6

5.1

79.9

LiHH 8×0.25

14/0.15

0.3

0.6

5.5

79.9

LiHH 10×0.25

14/0.15

0.3

0.7

6.6

79.9

LiHH 12×0.25

14/0.15

0.3

0.7

6.9

79.9

LiHH 14×0.25

14/0.15

0.3

0.7

7.2

79.9

0.34mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.34

20/0.15

0.3

0.6

4

57

LiHH 3×0.34

20/0.15

0.3

0.6

4.3

57

LiHH 4×0.34

20/0.15

0.3

0.6

4.6

57

LiHH 5×0.34

20/0.15

0.3

0.6

5

57

LiHH 7×0.34

20/0.15

0.3

0.6

5.4

57

LiHH 8×0.34

20/0.15

0.3

0.6

5.8

57

LiHH 10×0.34

20/0.15

0.3

0.7

7

57

LiHH 12×0.34

20/0.15

0.3

0.7

7.3

57

LiHH 14×0.34

20/0.15

0.3

0.7

7.6

57

0.50mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.5

16/0.20

0.3

0.6

4.3

39

LiHH 3×0.5

16/0.20

0.3

0.6

4.6

39

LiHH 4×0.5

16/0.20

0.3

0.6

5

39

LiHH 5×0.5

16/0.20

0.3

0.6

5.4

39

LiHH 7×0.5

16/0.20

0.3

0.6

5.9

39

LiHH 8×0.5

16/0.20

0.3

0.7

6.5

39

LiHH 10×0.5

16/0.20

0.3

0.7

7.6

39

LiHH 12×0.5

16/0.20

0.3

0.7

7.9

39

LiHH 14×0.5

16/0.20

0.3

0.7

8.3

39

0.75mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×0.75

24/0.20

0.4

0.6

5.2

26

LiHH 3×0.75

24/0.20

0.4

0.6

5.6

26

LiHH 4×0.75

24/0.20

0.4

0.6

6.1

26

LiHH 5×0.75

24/0.20

0.4

0.7

6.6

26

LiHH 7×0.75

24/0.20

0.4

0.7

7.2

26

LiHH 8×0.75

24/0.20

0.4

0.7

8

26

LiHH 10×0.75

24/0.20

0.4

0.8

9.6

26

LiHH 12×0.75

24/0.20

0.4

0.8

10

26

LiHH 14×0.75

24/0.20

0.4

0.9

10.7

26

1.0mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.0

32/0.20

0.5

0.6

5.8

19.5

LiHH 3×1.0

32/0.20

0.5

0.6

6.3

19.5

LiHH 4×1.0

32/0.20

0.5

0.7

7

19.5

LiHH 5×1.0

32/0.20

0.5

0.7

7.6

19.5

LiHH 7×1.0

32/0.20

0.5

0.9

8.5

19.5

1.5mm2

No. of Cores

Conductor
Construction (mm)

Insulation
Thickness (mm)

Sheath
Thickness (mm)

Overall
Diameter (mm)

Max. DCR
at 20℃ (Ω/km)

LiHH 2×1.5

30/0.25

0.5

0.6

6.4

13.3

LiHH 3×1.5

30/0.25

0.5

0.7

7.1

13.3

LiHH 4×1.5

30/0.25

0.5

0.7

7.7

13.3

LiHH 5×1.5

30/0.25

0.5

0.8

8.6

13.3

LiHH 7×1.5

30/0.25

0.5

1.0

9.6

13.3


Product detail pictures:

Renewable Design For Push Pull Control Cables - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures

Renewable Design For Push Pull Control Cables - LiHH Multicore Control Cable (Halogen Free)  – AIPU detail pictures


Related Product Guide:

We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for Renewable Design For Push Pull Control Cables - LiHH Multicore Control Cable (Halogen Free) – AIPU , The product will supply to all over the world, such as: Lithuania, Canada, Hamburg, We are looking forward to establishing a mutually beneficial relationship with you based on our high-quality products, reasonable prices and best service. We hope that our products will bring you a pleasant experience and carry a feeling of beauty.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Ada from Slovenia - 2018.06.12 16:22
    We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Judith from Moscow - 2018.09.16 11:31
    Write your message here and send it to us