Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission – AIPU


Product Detail

Product Tags

Related Video

Feedback (2)

We insist over the principle of enhancement of 'High high quality, Efficiency, Sincerity and Down-to-earth working approach' to offer you with superb assistance of processing for Quiet Server Rack, Wall Mount Cabinet, Combined Power And Signal Cable, In a word, when you choose us, you choose a ideal life. Welcome to go to our manufacturing unit and welcome your get! For further more inquiries, remember to usually do not be reluctant to get in touch with us.
Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission – AIPU Detail:

Application

1. The cable is designed for RS-485 Cable data communication and automation systems, microprocessor to device, etc. Multi-pair cables are available, they could be widely used for production process control, computer automation systems, automatic process control and controller application. RS485 allows multiple drops and long cable lengths,high-speed, so it is also frequently used in industrial and automation fields. The RS-485 is also used in large-space theater venues, automotive industry, where there is uncertainty about what noise will be encountered in the end application. It can realize long-distance cabling and also supports multiple devices on the same bus, can achieve most applications that require a serial interface intelligent.It is a kind of industrial specification. Rs-485 also commonly referred to as TIA-485 or EIA-485.
2 .Good performance on electric and data transmission.
3. Individually screened or overall tinned copper braided shielded could make the signal and date interference free.
4. Galvanized steel wire have a good tensile resistance performance. Widely used on the long distance transmission.
5. The S-FPE insulation make the date and signal telecommunication fast and steady.
6. PE sheath could be suitable for outdoor using.

Constructions

1. Conductor: Stranded Tinned Copper Wire
2. Insulation: S-PE, S-FPE
3. Cabling: Twist Pairs laying-up
4. Screened: Individually Screened (Optional)
    Al-PET tape with Tinned Copper Drain Wire
    Tinned Copper Wire Braided Screen
    Al-PET Tape & Tinned Copper Braided
5. Bedding for Armored Cable (Where Applicable):
    Polyethylene (PE)
    PVC
6. Armor (Where Applicable): Galvanized Steel Wire
7. Over sheath: PVC/LSZH

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 65℃

Reference Standards

TIA/EIA-485
BS EN 50288-7
BS EN 60228
BS EN 50290
RoHS Directives

Identification of Insulation

1st Pair

White, Blue

3rd Pair

White, Green

2nd Pair

White, Yellow

4th Pair

White, Brown

Electrical Performance

Working Voltage

300V

Characteristic Impedance

120 Ω ± 15 Ω

Velocity of Propagation

S-FPE: 78%, SPE: 66%

Conductor DCR

57.0 Ω/km (Max. @ 20°C) for 22AWG

91.80 Ω/km (Max. @ 20°C) for 24AWG

Part No.

Conductor Construction

Insulation

Screen

Sheath

Material

Size

AP9841

TC

1x2x24AWG

S-PE

Al-foil + Braid

PVC

AP9842

TC

2x2x24AWG

S-PE

Al-foil + Braid

PVC

AP9843

TC

3x2x24AWG

S-PE

Al-foil + Braid

PVC

AP9844

TC

4x2x24AWG

S-PE

Al-foil + Braid

PVC

AP9841NH

TC

1x2x24AWG

S-PE

Al-foil + Braid

LSZH

AP9842NH

TC

2x2x24AWG

S-PE

Al-foil + Braid

LSZH

AP9843NH

TC

3x2x24AWG

S-PE

Al-foil + Braid

LSZH

AP9844NH

TC

4x2x24AWG

S-PE

Al-foil + Braid

LSZH

AP3105A

TC

1x2x22AWG

S-FPE

Al-foil + Braid

PVC

AP3107A

TC

2x2x22AWG

S-FPE

Al-foil + Braid

PVC

AP3108A

TC

3x2x22AWG

S-FPE

Al-foil + Braid

PVC

AP3109A

TC

4x2x22AWG

S-FPE

Al-foil + Braid

PVC

(Notes: Other cores are available upon request.)


Product detail pictures:

Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission  – AIPU detail pictures

Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission  – AIPU detail pictures

Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission  – AIPU detail pictures


Related Product Guide:

We insist on the principle of development of 'High quality, Efficiency, Sincerity and Down-to-earth working approach' to provide you with excellent service of processing for Top Suppliers Cable Data Transfer - Communication Cable Building Wire EIA RS485 Cable 120ohm Communication Industrial Cable for Electric And Data Transmission – AIPU , The product will supply to all over the world, such as: Australia, Rio de Janeiro, Greece, Our faith is to be honest first, so we just supply high quality products to our customers. Really hope that we can be business partners. We believe that we can establish long time business relationship with each other. You can contact us freely for more information and pricelist of our products !
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Octavia from Washington - 2018.06.30 17:29
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Christine from Madras - 2017.05.02 18:28
    Write your message here and send it to us