Our primary target will be to provide our clients a serious and responsible small business relationship, supplying personalized attention to all of them for Electrical Control Cable, Standard Server Rack, Structured Data Cabling, We keep on with supplying integration alternatives for customers and hope to create long-term, steady, sincere and mutual advantageous interactions with consumers. We sincerely anticipate your check out.
Trending Products Shielded Instrument Cable - LiYY TP Multipair Control Cable – AIPU Detail:

Constructions

1. Conductor: Class 5 Oxygen Free Copper
2. Insulation: PVC
3. Identification: Colored
4. Cabling: Twisted Pair
5. Sheath: PVC

Installation Temperature: Above 0℃
Operating Temperature: -15℃ ~ 70℃

Reference Standards

VDE 0812
DIN 1704
VDE 0207
RoHS Directives
IEC60332-1

Section Area

Rated Voltage

Test Voltage

Min. Insulation
Resistance at 20℃ (MΩ/km)

0.14~0.34mm2

250/250V

1.2kV

200

0.5~0.75mm2

300V

2000V

200

1.0~1.5mm2

300/500V

3000V

200

0.14mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.14

12/0.12

0.35

0.4

3.2

148

LiYY TP 2x2x0.14

12/0.12

0.35

0.6

5.3

148

LiYY TP 3x2x0.14

12/0.12

0.35

0.6

5.7

148

LiYY TP 4x2x0.14

12/0.12

0.35

0.7

6.4

148

LiYY TP 6x2x0.14

12/0.12

0.35

0.7

7.5

148

LiYY TP 8x2x0.14

12/0.12

0.35

0.8

8.6

148

LiYY TP 10x2x0.14

12/0.12

0.35

0.9

10

148

LiYY TP 12x2x0.14

12/0.12

0.35

1

10.4

148

LiYY TP 15x2x0.14

12/0.12

0.35

1.1

11.6

148

0.25mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.25

14/0.15

0.4

0.4

3.6

79.9

LiYY TP 2x2x0.25

14/0.15

0.4

0.6

6

79.9

LiYY TP 3x2x0.25

14/0.15

0.4

0.6

6.4

79.9

LiYY TP 4x2x0.25

14/0.15

0.4

0.7

7.2

79.9

LiYY TP 6x2x0.25

14/0.15

0.4

0.8

8.8

79.9

LiYY TP 8x2x0.25

14/0.15

0.4

0.8

9.8

79.9

LiYY TP 10x2x0.25

14/0.15

0.4

1

11.5

79.9

LiYY TP 12x2x0.25

14/0.15

0.4

1

12.1

79.9

LiYY TP 15x2x0.25

14/0.15

0.4

1.1

13.5

79.9

0.34mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.34

20/0.15

0.4

0.5

4.2

57

LiYY TP 2x2x0.34

20/0.15

0.4

0.6

6.7

57

LiYY TP 3x2x0.34

20/0.15

0.4

0.6

7.2

57

LiYY TP 4x2x0.34

20/0.15

0.4

0.7

8

57

LiYY TP 6x2x0.34

20/0.15

0.4

0.9

10

57

LiYY TP 8x2x0.34

20/0.15

0.4

1

11.4

57

LiYY TP 10x2x0.34

20/0.15

0.4

1.1

13.1

57

LiYY TP 12x2x0.34

20/0.15

0.4

1.1

13.4

57

LiYY TP 15x2x0.34

20/0.15

0.4

1.2

14.9

57

0.50mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.5

16/0.20

0.45

0.6

4.8

39

LiYY TP 2x2x0.5

16/0.20

0.45

0.7

7.5

39

LiYY TP 3x2x0.5

16/0.20

0.45

0.7

8.1

39

LiYY TP 4x2x0.5

16/0.20

0.45

0.8

9

39

LiYY TP 6x2x0.5

16/0.20

0.45

1

11.2

39

LiYY TP 8x2x0.5

16/0.20

0.45

1.1

12.8

39

LiYY TP 10x2x0.5

16/0.20

0.45

1.2

14.7

39

LiYY TP 12x2x0.5

16/0.20

0.45

1.2

15

39

LiYY TP 15x2x0.5

16/0.20

0.45

1.3

16.7

39

0.75mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x0.75

24/0.20

0.5

0.6

5.4

26

LiYY TP 2x2x0.75

24/0.20

0.5

0.7

8.6

26

LiYY TP 3x2x0.75

24/0.20

0.5

0.8

9.5

26

LiYY TP 4x2x0.75

24/0.20

0.5

0.9

10.4

26

LiYY TP 6x2x0.75

24/0.20

0.5

1

12.7

26

LiYY TP 8x2x0.75

24/0.20

0.5

1.1

14.5

26

LiYY TP 10x2x0.75

24/0.20

0.5

1.2

16.7

26

LiYY TP 12x2x0.75

24/0.20

0.5

1.3

17.6

26

LiYY TP 15x2x0.75

24/0.20

0.5

1.4

19.6

26

1.0mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.0

32/0.20

0.6

0.6

6.2

19.5

LiYY TP 2x2x1.0

32/0.20

0.6

0.9

10.3

19.5

LiYY TP 3x2x1.0

32/0.20

0.6

1

11.4

19.5

LiYY TP 4x2x1.0

32/0.20

0.6

1

12.3

19.5

LiYY TP 6x2x1.0

32/0.20

0.6

1.2

15.2

19.5

LiYY TP 8x2x1.0

32/0.20

0.6

1.3

16.6

19.5

LiYY TP 10x2x1.0

32/0.20

0.6

1.4

19.8

19.5

1.5mm2

No. of Pairs

Conductor Construction (mm)

Insulation Thickness (mm)

Sheath Thickness (mm)

Overall Diameter (mm)

Max. DCR at 20℃ (Ω/km)

LiYY TP 1x2x1.5

30/0.25

0.6

0.6

6.8

13.3

LiYY TP 2x2x1.5

30/0.25

0.6

1

11.5

13.3

LiYY TP 3x2x1.5

30/0.25

0.6

1.1

12.7

13.3

LiYY TP 4x2x1.5

30/0.25

0.6

1.2

13.9

13.3

LiYY TP 6x2x1.5

30/0.25

0.6

1.3

16.9

13.3

LiYY TP 8x2x1.5

30/0.25

0.6

1.3

18.3

13.3


Product detail pictures:

Trending Products Shielded Instrument Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures

Trending Products Shielded Instrument Cable - LiYY TP Multipair Control Cable  – AIPU detail pictures


Related Product Guide:

No matter new customer or outdated client, We believe in extensive phrase and trusted relationship for Trending Products Shielded Instrument Cable - LiYY TP Multipair Control Cable – AIPU , The product will supply to all over the world, such as: America, UK, Seychelles, For many years, we now have adhered to the principle of customer oriented, quality based, excellence pursuing, mutual benefit sharing. We hope, with great sincerity and good will, to have the honor to help with your further market.
  • This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Cornelia from Washington - 2017.05.21 12:31
    Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Jill from Leicester - 2018.12.28 15:18
    Write your message here and send it to us